Hematology Analyzer Reagents Hematology Reagent For Erma Pce-210 Analyzers High Quality

 

Intended Use

The hematology ana;yzer reagents to be used for blood cell counting, sizing, and WBC differentiation, hemoglobin determination on Erma PCE-210 hematology analyzers. This product is for In Vitro Diagnostic Use only.

 

Specification

80-10-020DILUENT CM20L
80-30-005LYSE CM500mL
80-40-001CLEANER CM1L

 

Kit Composistion

DILUENT CMNaCl≤9.4%, Buffer≤1.6%, Anti-Microbial Agent≤1.0%
LYSE CMQuaternary Ammonium Salt<10%, Sodium Lauryl Sulfate<1.5%
CLEANER CM

Buffer<0.3%, Proteolytic Enzyme<0.2%

 

Applicable Insteument

For use with Erma PCE-210 hematology analyzers.

 

Procedures

  • Remove all the reagent aspiration tubes from the currently used reagent boxes or bottles.
  • Wipe the tube’s surface with a lent free tissue, and then rinse with distilled water.
  • Put the tubes into the LABNOVATION reagent boxes or bottles.
  • Run at least 50 backgrounds. Check for the acceptable values. At first high background counts can be seen, that should lower to normal after a few runs.
  • Run all three levels of a dedicated commercial control. Check for the acceptable values.
  • Recalibrate the unit if necessary.

Storage

Store the product at 5-35℃ in a dust free place with good ventilation. Temperature outside the range may damage the product.

The open vial life of the product is 30 or 60 days (according to the table above). Unused reagents should be discarded after period of validity. Do not mix residual with a new carton.

 

Precautions

  1. Re-calibration is recommended when changing the origin of the reagents.
  2. It is not recommended using different brands of solutions together on one unit of analyzer.
  3. Do not ingest. Avoid contact with skin and eyes.
  4. Skin contact: Flush with plenty of water.
  5. Eyes contact: Flush with plenty of water. Obtain immediate medical attention.
  6. This kit is for professionals and in vitro diagnostic use only.

 

Hot Products

Hematology Analyzer Reagents Hematology Reagent For CD3200 Analyzers High Quality Rreagents Intended ...
Hematology Analyzer Reagents Hematology Reagent For CD3200 Analyzers High Quality Rreagents Intended ...
Hematology Reagent For Coulter Stks, Maxm, Hmx Analyzers High Quality Adn Purity Reagents Intended ...
Hematology Reagents High Purity Reagents Hematology Reagent For Mindray BC-5000, BC-5150 Analyzers ...
Hematology Analyzer Reagents Hematology Reagent For Erma Pce-210 Analyzers High Quality Intended Use ...
Hematology Analyzer Reagents Hematology Reagent For Hospitex Hema Screen Analyzers Intended Use To ...