Product Details

Hematology Analyzer Reagents Hematology Reagent For Hospitex Hema Screen Analyzers

 

Intended Use

To be used for blood cell counting, sizing, and WBC differentiation, hemoglobin determination on Hospitex Hema Screen hematology analyzers. This product is for In Vitro Diagnostic Use only.

 

Specification

L-70010070DILUENT HX20L
L-70010075LYSE HX500ml
L-70010085CLEANER HX5L

Kit Composition

DILUENT HXNaCl≤9.4%, Buffer≤1.6%, Anti-Microbial Agent≤1.0%
LYSE HXQuaternary Ammonium Salt<10%, Sodium Lauryl Sulfate<1.5%
CLEANER HX

Sodium Sulfate<1.5%, Anti-microbial Agent<0.1%

Application

For use with Hospitex Hema Screen hematology analyzers.

 

Procedures

  • Remove all the reagent aspiration tubes from the currently used reagent boxes or bottles.
  • Wipe the tube’s surface with a lent free tissue, and then rinse with distilled water.
  • Put the tubes into the LABNOVATION reagent boxes or bottles.
  • Run at least 50 backgrounds. Check for the acceptable values. At first high background counts can be seen, that should lower to normal after a few runs.
  • Run all three levels of a dedicated commercial control. Check for the acceptable values.
  • Recalibrate the unit if necessary.

Storage

Store the product at 5-35℃ in a dust free place with good ventilation. Temperature outside the range may damage the product.

The open vial life of the product is 30 or 60 days (according to the table above). Unused reagents should be discarded after period of validity. Do not mix residual with a new carton.

 

Precautions

  • Re-calibration is recommended when changing the origin of the reagents.
  • It is not recommended using different brands of solutions together on one unit of analyzer.
  • Do not ingest. Avoid contact with skin and eyes.
  • Skin contact: Flush with plenty of water.
  • Eyes contact: Flush with plenty of water. Obtain immediate medical attention.
  • This kit is for professionals and in vitro diagnostic use only.

Hot Products

Hematology Analyzer Reagents Hematology Reagent For CD3200 Analyzers High Quality Rreagents Intended ...
Hematology Reagent For Coulter Stks, Maxm, Hmx Analyzers High Quality Adn Purity Reagents Intended ...
Hematology Reagents High Purity Reagents Hematology Reagent For Mindray BC-5000, BC-5150 Analyzers ...
Hematology Analyzer Reagents Hematology Reagent For Erma Pce-210 Analyzers High Quality Intended Use ...
Hematology Analyzer Reagents Hematology Reagent For Hospitex Hema Screen Analyzers Intended Use To ...
Hematology Analyzer Reagentshematology Reagent For Humacount Series Analyzers Intended Use To be ...