Home Companies Labnovation Technologies, Inc.

CD3200 Hematology Analyzer Reagents OEM Blood Test Reagents

Labnovation Technologies, Inc.
Active Member

Contact Us

[China] country

Address: 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China

Contact name:Aimee li

Inquir Now

Labnovation Technologies, Inc.

CD3200 Hematology Analyzer Reagents OEM Blood Test Reagents

Country/Region china
City & Province shenzhen
Categories Dyestuff Intermediates
InquireNow

Product Details

Hematology Analyzer Reagents Hematology Reagent For CD3200 Analyzers High Quality Rreagents

 

Intended Use

To be used for blood cell counting, sizing, and WBC differentiation, hemoglobin determination on ABBOTT CD3200 hematology analyzers. This product is for In Vitro Diagnostic Use only.

Procedures
  • Using the function keys press the following menus:

MAIN-SPECIAL PROTOCOLS-REAGENT RESERVOIRE-EMTY DILUENT

  • Remove the reagent inlet tube from the Diluent.
  • Wipe the tube’s surface with a lent free tissue, and then rinse with distilled water.
  • Put the reagent tubes into the boxes and/or bottles of Labnovation reagents.
  • Using the function keys press the following menu:

FILL DILUENT

This step will fill the reagent system with Labnovation reagent.

  • Repeat steps 1-5 with Lyse and Sheath.
  • Run at least 5 backgrounds. Check for the acceptable values.
  • Run all three levels of a dedicated commercial control. Check for the acceptable values.
  • Recalibrate the unit if necessary. (MAIN-CALIBRATION-ENTER-FACTOR)
Precautions
  • Re-calibration is recommended when changing the origin of the reagents.
  • It is not recommended using different brands of solutions together on one unit of analyzer.
  • Do not ingest. Avoid contact with skin and eyes.
  • Skin contact: Flush with plenty of water.
  • Eyes contact: Flush with plenty of water. Obtain immediate medical attention.
  • This kit is for professionals and in vitro diagnostic use only.
  • Never put distilled water on the analyser (except clean for shipping menu), otherwise the pneumatic unit can be damaged seriously.

Specification

L-8547196RET STAIN380 ML
L-8547197RET LYSE1900 ML
L-8546983LYSE DIFF1 L
L-8546733ISOTONIC DILUENT20 L
L-8546930E-CLEANER5 L

 

KIT COMPOSITION

RET STAIN

New Methylene Blue 0.06%

RET LYSESulfuric Acid 0.15%
LYSE DIFF

Quaternary Ammonium Salt<10%, Sodium Lauryl Sulfate<1.5%

ISOTONIC DILUENT

NaCl≤9.4%, Buffer≤1.6%, Anti-Microbial Agent≤1%

E-CLEANERBuffer<0.3%, Proteolytic Enzyme<0.2%
 

APPLICABLE INSTUMENT

  • For use with CD3200 hematology analyzers.
Advantage
  • One source for all brands of analyzer 
  • Reagents for both 3-parts and 5-parts
  • Ready-to-use final products and bulk OEM reagents
  • ISQ13485:2003 and ISO9001:2008 certified
  • CE marked, FDA cleared
  • Well-established brand used by thousands of lab in 95 countries
  • High quality, high performance and high fidelity of correlations with original brand.

Storage

 

  • Store the product at 5-35℃ in a dust free place with good ventilation. Temperature outside the range may damage the product.
  • The open vial life of the product is 30/60 days. Unused reagents should be discarded after 30/60 days. Do not mix residual with a new carton.

 

 
 

Hot Products

Clinical Chemistry Reagents High Quality And High Purity Clinical Reagents For Open Systems Intended ...
Hematology Reagent For Labnovation Diffen 5 Analyzers Excellent Quality Analyzer Reagents Intended ...
Hematology Analyzer Reagents Abbott Hematology Reagent For CD3200 Analyzer Use Intended Use To be ...
Hematology Reagent For Coulter Gen.S , LH-750, LH-780, DXH-800 Analyzers High Quality Reagents ...
Hematology Analyzer Reagents Hematology Reagent For CD3200 Analyzers High Quality Rreagents Intended ...
Hematology Analyzer Reagents Hematology Reagent For CD3200 Analyzers High Quality Rreagents Intended ...