Product Details

 

Product Name

Medical Blood Oxygen Saturation Pulse Monitoring Home Heartbeat Heart

Rate Detector Oximeter Finger Clip

 

 

 

Function Specification

Display InformationDisplay Mode
The Pulse Oxygen Saturation(SpO2)LED
Pulse Rate(PR)LED
Pulse Intensity (bar -graph)LED
Pulse waveLED
SpO2 Parameter Specification
Measuring range0%~-100%, (the resolution is 1%).
Accuracy70%~100%±2%, Below 70% unspecified.
Optical Sensor

Red light (wavelength is 660nm)

Infrared (wavelength is 880nm)

Pulse Parameter Specification
Measuring range30bpm~250bpm (the resolution is 1 bpm)
Accuracy±2bpm or±2% select larger
Pulse Intensity
RangeContinuous bar-graph display, the higher display indicate the strong pulse
Battery Requirement
1.5V (AAA size) alkaline batteries x 2 or rechargeable battery
Battery Useful Life
Two batteries can work continally for 20 hours
Dimensions and Weight 
Dimensions57(L) x 31(W) x 32(H) mm .
WeightAbout 50g (with the batteries)

 

 

Troubleshooting

TroublePossible ReasonSolution

The SpO2 and Pulse Rate can not be displayed normally

 

1. The finger is not properly positioned.

2. The patient's SpO2 is too low to be detected.

 

1. Place the finger properly and try again.

2. Try again; Go to a hospital for a diagnosis if you are sure the device works all right.

The SpO2 and Pulse

Rate are not

displayed stably

 

1. The finger is not placed inside deep enough.

2. The finger is shaking or the patient is moving.

1. Place the finger properly and try again.

2. Let the patient keep calm

 

The device can not

be turned on

 

1. The batteries are drained or almost drained.

2. The batteries are not inserted properly.

3. The malfunction of the device.

1. Change batteries.

2. Reinstall batteries.

3. Please contact the local service center.

 

The display is off

suddenly

 

1. The device will power off

automatically when it gets no signal within 5 seconds.

2. The batteries are almost drained.

1. Normal.

2. Change batteries.

 

 

Warning

 

    1,The uncomfortable or painful feeling may appear if using the device ceaselessly, especially for the microcirculation barrier patients. It is recommended that the sensor should not be applied to the same finger for over 2 hours.

 

    2,For the individual patients, there should be a more prudent inspecting in the placing process. The device can not be clipped on the edema and tender tissue.

 

    3,The light (the infrared is invisible) emitted from the device is harmful to the eyes, so the user and the maintenance man, can not stare at the light.

 

  4,Testee can not use enamel or other makeup.

 

  5,Testee's fingernail can not be too long.

 

  6,Please peruse the relative content about the clinical restrictions and caution.

 

  7,This device is not intended for treatment.

 

 

Operating Guide

 

1) Insert the two batteries properly to the direction, and then replace the cover.

2) Open the clip as shown in Figure 5.

 

3) Let the patient's finger put into the rubber cushions of the clip (make sure the finger is in the right position), and then clip the finger.

4) Press the switch button once on front panel.

5) Do not shake the finger and keep t he patient at ease during the process. Meanwhile, human body is not recommended in movement status.

6) Get the infonnation directly from screen display.

7) The button has three functions. When the device is power off, pressing the button can open it; When the device is power on, pressing the button shortly can change direction of the screen; When the device is power on, pressing the button long can change brightness of the screen

 

► Fingern ails and the luminescent tube should be on the same side

 

 

 

 

 

 

 

Hot Products

Fingertip pulse oximeters - easy to use ,small in volume,low power consumption,convenient operation ...
Product Name Medical Blood Oxygen Saturation Pulse Monitoring Home Heartbeat Heart Rate Detector ...
Product Name Portable LED Screen ABS Plastic Household Blood Oxygen Saturation Monitor Fingertip ...
Product Name Large OLED Display Portable Finger Pulse Oximeter Blood Oxygen Saturation Monitor SPO2 ...
Product Name Portable Medical Home LED Screen Clear Reading Fingertip Pulse Oximeter Feature ...
Product Name Medical Home Easy Use Digital Accurate SPO2 Blood Oxygen Saturation Pulse Oximeter ...