Results for11268435 ultrasound repair servicefrom 19372 Products.
|
Mindray DC-3 Abnormal Image Ultrasound Machine Repair Solutions Model: Mindray DC-3 Mindray DC-3 image loss is abnormal. All probes are faulty after switching, and it is judged ...
|
|
|
|
Medical Ultrasound Equipment Hitachi HI VISION Avius Bright Channels Faulty 1. Repair time: 2-4 days 2. Warranty: 60 days Fault analysis and treatment: All the probes of the device ...
|
|
|
|
Hitachi ARIETTA 60 Occasional Hints That Probe Detection Is Invalid Ultrasound Machine Repair 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault analysis and treatment: The ...
|
|
|
|
Hitachi EUP-C715 Surgical Instruments Convex Abdominal Repair Ultrasound Probe 1.Model: EUP-C715 2.Repair Time: 2-5 days 6.With 60 days warranty Parts of GE probes we can offer: ...
|
|
|
|
Ultrasonic Board CX50 Control Board(453561685791) Control Panel/ Imaging Device Original ultrasound CX50 Control panel(453561685791) 1. Part number: 453561685791 2. Compatible ...
|
|
|
|
Toshiba Xario SSA-660A Trackball Ultrasound System Accessories 1. Compatible system: Toshiba Nemio SSA-550A 2. in excellent working condition 3. with 60 days warranty 4. Model...
|
|
|
|
GE 11L-D Linear Ultrasound Probe Hospital Equipment Imaging Small Parts 1. Type: Linear 2.Compatible system: Logiq E9, Vivid E9, Vivid E95, Voluson E6, Voluson E8 3. Frequency: 5.9...
|
|
|
|
GE RIC5-9A-RS 4D Probe Motor Repair Motor Control Failures Motor control failures If the array stops moving or gets stuck, the motor control function has failed and may need to be ...
|
|
|
|
Motor Repair GE RAB2-5-D 4D Probe Motor Control Failures Motor control failures If the array stops moving or gets stuck, the motor control function has failed and may need to be ...
|
|
|
|
Repair Philips IU22 IE33 453561210241/453561210243 AIM board Spare Parts 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Part Number: 453561210241/453561210243 4. Compatible for ...
|
|
|
|
Repair 3D/4D GE RAB4-8-D Crystal/Crystal Replacement/Broken Probes Crystal damage -Weak, dead, or damaged crystals Very often the cause of crystal damage in ultrasound probes is ...
|
|
|
|
Repair GE 3SC-RS Crystal/Crystal Replacement/Damaged Crystals Crystal failure reason Most internal ultrasound probe uses a piezoelectric crystal. After long-term use, it can be ...
|
|
|
|
Repair 4D V6-2 IU22/IE33 Cable/Connecting Cable Leakage/Damaged Cable Cable leakage failure reason and solution Ultrasound probe cable is adopted by high quality of high multi...
|
|
|
|
Fix CX50 Control Board(P/N: 453561685791) 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Part number: 453561685791 4. Compatiable with CX50 Various GE//Siemens/Toshiba/Hitachi/ ...
|
|
|
|
Repair GE Logiq P5 SYSCONPM Board 5177848-3 1. Part number: 5177848-3 2. Compatible with GE Logiq P5 3. With 60 days warranty after fixed 4. Maintenance time: 2-4 days Note: ...
|
|
|
|
Samsung V5-9 Ultrasound Probe Repair Oil and Sealing Problem Oil leakage Probe Troubleshooting Summary 1. Check whether multiple probes are the same phenomenon, sometimes it is ...
|
|
|
|
Strain Relief is worn/dark shadows Samsung EVN4-9 Ultrasound Probe Repair Among the more common issues is a crack or separation in the strain relief. This problem occurs most often ...
|
|
|
|
GE Logiq E9 Medical Imaging Machines Repair GE Logiq E9 System Reports Error Failure phenomenon GE LOGIQ E9 color Doppler ultrasound frequently crashes after turning on. ecer(...
|
|
|
|
Hitachi Aloka Noblus Operating Room Supplies Repair Hitachi Aloka Noblus System Reports Error Faults phenomenon The power button of the portable ultrasound is not working, and the ...
|
|
|
|
IE33 Ultrasound Diagnostic System Repair IE33 System Reports Error The parts with high failure rate&available in stock of this machine: 1.CB Board (Channel Board)(453561156011...
|
|
|