11268435 ultrasound repair service

Refine Search
Results for11268435 ultrasound repair servicefrom 19372 Products.
Mindray DC-3 Abnormal Image Ultrasound Machine Repair Solutions Model: Mindray DC-3 Mindray DC-3 image loss is abnormal. All probes are faulty after switching, and it is judged ...
Guangdong, china
Verified
Medical Ultrasound Equipment Hitachi HI VISION Avius Bright Channels Faulty 1. Repair time: 2-4 days 2. Warranty: 60 days Fault analysis and treatment: All the probes of the device ...
Guangdong, china
Verified
Hitachi ARIETTA 60 Occasional Hints That Probe Detection Is Invalid Ultrasound Machine Repair 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault analysis and treatment: The ...
Guangdong, china
Verified
Hitachi EUP-C715 Surgical Instruments Convex Abdominal Repair Ultrasound Probe 1.Model: EUP-C715 2.Repair Time: 2-5 days 6.With 60 days warranty Parts of GE probes we can offer: ...
Guangdong, china
Verified
Ultrasonic Board CX50 Control Board(453561685791) Control Panel/ Imaging Device Original ultrasound CX50 Control panel(453561685791) 1. Part number: 453561685791 2. Compatible ...
Guangdong, china
Verified
Toshiba Xario SSA-660A Trackball Ultrasound System Accessories 1. Compatible system: Toshiba Nemio SSA-550A 2. in excellent working condition 3. with 60 days warranty 4. Model...
Guangdong, china
Verified
GE 11L-D Linear Ultrasound Probe Hospital Equipment Imaging Small Parts 1. Type: Linear 2.Compatible system: Logiq E9, Vivid E9, Vivid E95, Voluson E6, Voluson E8 3. Frequency: 5.9...
Guangdong, china
Verified
GE RIC5-9A-RS 4D Probe Motor Repair Motor Control Failures Motor control failures If the array stops moving or gets stuck, the motor control function has failed and may need to be ...
Guangdong, china
Verified
Motor Repair GE RAB2-5-D 4D Probe Motor Control Failures Motor control failures If the array stops moving or gets stuck, the motor control function has failed and may need to be ...
Guangdong, china
Verified
Repair Philips IU22 IE33 453561210241/453561210243 AIM board Spare Parts 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Part Number: 453561210241/453561210243 4. Compatible for ...
Guangdong, china
Verified
Repair 3D/4D GE RAB4-8-D Crystal/Crystal Replacement/Broken Probes Crystal damage -Weak, dead, or damaged crystals Very often the cause of crystal damage in ultrasound probes is ...
Guangdong, china
Verified
Repair GE 3SC-RS Crystal/Crystal Replacement/Damaged Crystals Crystal failure reason Most internal ultrasound probe uses a piezoelectric crystal. After long-term use, it can be ...
Guangdong, china
Verified
Repair 4D V6-2 IU22/IE33 Cable/Connecting Cable Leakage/Damaged Cable Cable leakage failure reason and solution Ultrasound probe cable is adopted by high quality of high multi...
Guangdong, china
Verified
Fix CX50 Control Board(P/N: 453561685791) 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Part number: 453561685791 4. Compatiable with CX50 Various GE//Siemens/Toshiba/Hitachi/ ...
Guangdong, china
Verified
Repair GE Logiq P5 SYSCONPM Board 5177848-3 1. Part number: 5177848-3 2. Compatible with GE Logiq P5 3. With 60 days warranty after fixed 4. Maintenance time: 2-4 days Note: ...
Guangdong, china
Verified
Samsung V5-9 Ultrasound Probe Repair Oil and Sealing Problem Oil leakage Probe Troubleshooting Summary 1. Check whether multiple probes are the same phenomenon, sometimes it is ...
Guangdong, china
Verified
Strain Relief is worn/dark shadows Samsung EVN4-9 Ultrasound Probe Repair Among the more common issues is a crack or separation in the strain relief. This problem occurs most often ...
Guangdong, china
Verified
GE Logiq E9 Medical Imaging Machines Repair GE Logiq E9 System Reports Error Failure phenomenon GE LOGIQ E9 color Doppler ultrasound frequently crashes after turning on. ecer(...
Guangdong, china
Verified
Hitachi Aloka Noblus Operating Room Supplies Repair Hitachi Aloka Noblus System Reports Error Faults phenomenon The power button of the portable ultrasound is not working, and the ...
Guangdong, china
Verified
IE33 Ultrasound Diagnostic System Repair IE33 System Reports Error The parts with high failure rate&available in stock of this machine: 1.CB Board (Channel Board)(453561156011...
Guangdong, china
Verified