AC Outdoor GW5 Anti Electrodynamic 1600A HV Disconnect Switch 126KV

 

 Overview

GW5 (GT10)-126D/1600-40 Type Outdoor AC HV Disconnector is developed on the basis of aiming at the GW5-126 type disconnector existing defect about earthing flashover, large operating force, contact leaves contact area when bevel gear tooth broken or closing position out of control and under the action of wind, through investigation and analysis. It is the update product our company recommends to HV power distribution network.

It is suitable for system with 50Hz AC frequency and 110kV rated voltage. It can be used in changing-over when HV circuit is no-load and electricity isolate maintained HV busbar, circuit breaker and other electrical equipments and alive HV wire, as well as used for breaking small capacitance current or inductive current.

 

AC Outdoor GW5 Anti Electrodynamic 1600A HV Disconnect Switch 126KV​ environment condition
1. Altitude: no more than 1000m;(The excess needs to be explained in advance)
2. Ambient air temperature: - 30 + 40;
3. Relative humidity of surrounding environment: the daily average is no more than 95%;
4. The monthly average value is not more than 90%. The earthquake intensity does not exceed 8;
5. Safe place: no fire, inflammable, explosive, serious pollution, chemical corrosion and violent vibration

 

Features of AC Outdoor GW5 Anti Electrodynamic 1600A HV Disconnect Switch 126KV​

a. Reasonable principle, simple design.

b. Strong anti-electrodynamic force, the short-circuit current can reach 40kV/3s.

c. Horizontal single fracture. Obvious and reliable insulating isolating distance can be formed under opening status, which is convenient to maintain and operation. Interlock is reliable.

d. Beautiful appearance and covers little area.

 

Parameters of AC Outdoor GW5 Anti Electrodynamic 1600A HV Disconnect Switch 126KV​

 

S/NNameUnitParameters
1Rated voltagekV126
2Rated currentA630,1250,1600
3Rated peak withstand current of disconnector and earthing switch (peak)kA50,80,100
43s rated short-time withstand current of disconnector and earthing switch (r.m.s)kA20,31.5,40
5Mechanical life of disconnector and earthing switchTimes2000 for each
6Main circuit resistance of disconnectorμΩ≤75
7Rated lightning impulse withstand voltage (peak)Phase-to-phase, to earthkV550
Isolating distance630

Hot Products

Electrical Anti Electrodynamic Space Saving GT10 HV Disconnect Switch 1250A Electrical Anti ...
Single Pole Fused Disconnect Switch Electricity Isolation Overview GW22 (GT8)-126D/1600-31.5 ...
DC 252kv 125KA HV Disconnect Switch Loop Overheating Loop Overheating General overview GW23 (GT9) ...
AC 145kv High Voltage Disconnect Switch 1000m GW4 No Load Change These disconnectors are , no load ...
AC Outdoor GW5 Anti Electrodynamic 1600A HV Disconnect Switch 126KV Overview GW5 (GT10)-126D/1600-40 ...
252kv 2500A High Voltage Disconnect Switch Disconnector Isolator GW23 General overview GW23(GT9)252D...