Electrical Anti Electrodynamic Space Saving GT10 HV Disconnect Switch 1250A Overview

GW5 (GT10)-126D/1600-40 Type Outdoor AC HV Disconnector is developed on the basis of aiming at the GW5-126 type disconnector existing defect about earthing flashover, large operating force, contact leaves contact area when bevel gear tooth broken or closing position out of control and under the action of wind, through investigation and analysis. It is the update product our company recommends to HV power distribution network.

It is suitable for system with 50Hz AC frequency and 110kV rated voltage. It can be used in changing-over when HV circuit is no-load and electricity isolate maintained HV busbar, circuit breaker and other electrical equipments and alive HV wire, as well as used for breaking small capacitance current or inductive current.

 

Features of Electrical Anti Electrodynamic Space Saving GT10 HV Disconnect Switch 1250A

a. Reasonable principle, simple design.

b. Strong anti-electrodynamic force, the short-circuit current can reach 40kV/3s.

c. Horizontal single fracture. Obvious and reliable insulating isolating distance can be formed under opening status, which is convenient to maintain and operation. Interlock is reliable.

d. Beautiful appearance and covers little area.

 

Electrical Anti Electrodynamic Space Saving GT10 HV Disconnect Switch 1250A  Parameters

 

S/NNameUnitParameters
1Rated voltagekV126
2Rated currentA630,1250,1600
3Rated peak withstand current of disconnector and earthing switch (peak)kA50,80,100
43s rated short-time withstand current of disconnector and earthing switch (r.m.s)kA20,31.5,40
5Mechanical life of disconnector and earthing switchTimes2000 for each
6Main circuit resistance of disconnectorμΩ≤75
7Rated lightning impulse withstand voltage (peak)Phase-to-phase, to earthkV550
Isolating distance630

Hot Products

GW4 Three - Phase Outdoor AC HV Disconnecting Switch 126KV with Earthing Switch Description of GW4 ...
35kv High Voltage Monopole Type Disconnect Switch / Power Isolator In Outdoor General GW4-40.5 ...
Fused Outdoor 12kv 3000m Sea Level HV Disconnect Switch 50hz Fused Outdoor 12kv 3000m Sea Level HV ...
35KV 3 Phase 630A 3000M Altitude 4S Outdoor Disconnect Switch Main Characteristics of 35KV 3 Phase ...
Electrical Anti Electrodynamic Space Saving GT10 HV Disconnect Switch 1250A Electrical Anti ...
Single Pole Fused Disconnect Switch Electricity Isolation Overview GW22 (GT8)-126D/1600-31.5 ...