4D Samsung V5 9 Ultrasound Probe Repair Replace Strain Relief

Country/Region china
City & Province guangzhou guangdong
Categories Screen Protectors
InquireNow

Product Details

 

Repair 4D Samsung V5-9 Strain Relief

 

Among the more common issues is a crack or separation in the strain relief. This problem occurs most often where the probe attaches to the cable, but also can occur at the transducer connector.

This problem is easy to spot, as shown in the picture on the right. This is one of the most important problems to address quickly because eventually it will affect your image. Ultimately you will damage the wires inside the cable and it will result in image dropout or complete loss of the ultrasound image.

 

Solution

Replace the strain relief 
 

 

 

 


 

 

 

 

Other hot models we can repair:

 

Brand Model
AlokaUST-52101
AlokaUST-52105
AlokaUST-5299
AlokaUST-5412
AlokaUST-5413
AlokaUST-9118
AlokaUST-984-5
AlokaUST-9123
AlokaUST-9124
AlokaUST-9130
Biosound BiosoundCA541
Biosound BiosoundCA621
Biosound BiosoundCA431
Biosound BiosoundCA123
Biosound BiosoundLA523
Biosound BiosoundEC123
Biosound BiosoundEC1123
Biosound BiosoundPA230E

 

 

 

Common ultrasound Probe Damage(Specialty 3D/4D Volume probes)

 

Common ultrasound probe damageSolutions
Lens cap damageLens cap replacement
Fluid and oil leaksLens cap replacement, oil reservoir repair and replacement
Cable cutsCable patches, possible cable replacement
Inoperative steeringMotor repair
Connector housing electrical damageMinor electrical repairs, pin module replacement
Weak or dead elements, dropouts in an imageArray ball replacement, oil reservoir repair and replacement

 

 


We provide repair service on most common probes, 3D/4D transducers, and Endo/TEE probes.

With 10 years experiences on probe repair, our technical engineer team own the most advanced probe repair processes, which enables us to fix probes from a basic lens fault to 4D /TEE fault.

Once repaired, all probes will go through an extensive testing process ,until reach their optimal condition.

 

 

FAQ

 

How to identify a defective probe?

 

If the probe has a broken membrane or cracked wire, you can see it immediately. But what if the defect is not noticeable?

Ultrasound probes send and receive ultrasonic signals into the body and create an image. If that image has any dropouts, your probe might have defects.

 

The most commonly occurring problems are related to wiring sheath or membrane. But you can also get a connector refurbishment, crystal replacement, and more.

Tee transducers are particularly expensive ones and usually get bitten by patients. The tiny defects on tee probes are tough to notice.

 

You can identify the defects by simple monitoring, such as looking for bite marks, corrosive parts, or crushed tubes.

Even a small defect in the Tee probe could be severe for patients. If at all you have a defective tee probe, PRS can lend you one while repairing yours.

Hot Products

Ultrasound Transducer Repair, Repair Ultrasonic Lens, Crystal, Probe Connector, Cable, Strain Relief...
Repair 4D Samsung V5-9 Strain Relief Among the more common issues is a crack or separation in the ...
Repair 4D Siemens 7CF2 Acuson Lens Cap/Fluid And Oil Leaks/Leaking Oil Fluid and oil leaks Solution ...
Repair 3D/4D GE RAB4-8-D Crystal/Crystal Replacement/Broken Probes Crystal damage -Weak, dead, or ...
Repair Toshiba PLT-805AT Pin/Repair Connector/Broken Pins/Locking Shafts​ Probe connectors are the ...
Repair Toshiba PVU-375BT Lens/Lens Replacement/Repair Service The lens of failures Reasons An ...