Repair 4D Siemens 7CF2 Acuson Lens Cap/Fluid And Oil Leaks/Leaking Oil

 

Fluid and oil leaks

 

Solution

 
Lens cap replacement, oil reservoir repair and replacement
 

 

 

 

 

Other hot models we can repair:

 

BrandModel
ToshibaPLT-704AT
ToshibaPLT-604AT
ToshibaPLT-805AT
ToshibaPLT-1005BT
ToshibaPLT-1204AT
ToshibaPLT-704SBT
ToshibaPST-30BT
ToshibaPST-25ST
ToshibaPVM-375AT
ToshibaPVT-375BT
ToshibaPVT-712BT
ToshibaPVM-651VT
ToshibaPVM-621VT
ToshibaPVT-382BT
ToshibaPVT-674BT
ToshibaPVT-661VT
ToshibaPVT-675MV
ToshibaPVT-575MV
ToshibaPVT-681MV
ToshibaPLU-1204BT
ToshibaPSU-25BT(5S1)
ToshibaPSU-30BT(5S2)
SiemensEV-8C4 (S2000)
SiemensEC9-4(S2000)
Siemens4V1C (S2000)
SiemensP5-1 (X300)
Siemens6C1HD (S2000)
Siemens18L6HD (S2000)

 

 

 

Common ultrasound Probe Damage(Specialty 3D/4D Volume probes)

 

Common ultrasound probe damageSolutions
Lens cap damageLens cap replacement
Fluid and oil leaksLens cap replacement, oil reservoir repair and replacement
Cable cutsCable patches, possible cable replacement
Inoperative steeringMotor repair
Connector housing electrical damageMinor electrical repairs, pin module replacement
Weak or dead elements, dropouts in an imageArray ball replacement, oil reservoir repair and replacement

 

 


We provide repair service on most common probes, 3D/4D transducers, and Endo/TEE probes.

With 10 years experiences on probe repair, our technical engineer team own the most advanced probe repair processes, which enables us to fix probes from a basic lens fault to 4D /TEE fault.

Once repaired, all probes will go through an extensive testing process ,until reach their optimal condition.

 

 

 

Storage for Transport of ultrasonic transducer

 

  • Make sure that the transducer is clean and disinfected before placing it in the case to avoid contaminating the foam that lines the carrying case.
  • Place the transducer in the case carefully to prevent kinking of the cable.
  • Before closing the lid, make sure no part of the transducer is protruding from the case.
  • Wrap the case in plastic material containing sealed-air pockets (such as Bubble Wrap material), and pack the wrapped case in a cardboard carton.

 


Daily and Long-Term Storage of ultrasound transducer

 

1. Always store transducers in the transducer holders on the side of your system or on a securely mounted wall rack when you are not using them.

2. Ensure the transducer holders are clean before storing transducers

3. When storing transducers, use the cable-management clips, if available, to secure the transducer cable

4. Avoid storing transducers in areas of temperature extremes or in direct sunlight.

5. Store transducers separately from other instruments to avoid inadvertent transducer damage.

6. Before storing transducers, make sure they are thoroughly dry.

 



Hot Products

Ultrasound Transducer Repair, Repair Ultrasonic Lens, Crystal, Probe Connector, Cable, Strain Relief...
Repair 4D Samsung V5-9 Strain Relief Among the more common issues is a crack or separation in the ...
Repair 4D Siemens 7CF2 Acuson Lens Cap/Fluid And Oil Leaks/Leaking Oil Fluid and oil leaks Solution ...
Repair 3D/4D GE RAB4-8-D Crystal/Crystal Replacement/Broken Probes Crystal damage -Weak, dead, or ...
Repair Toshiba PLT-805AT Pin/Repair Connector/Broken Pins/Locking Shafts​ Probe connectors are the ...
Repair Toshiba PVU-375BT Lens/Lens Replacement/Repair Service The lens of failures Reasons An ...