Zhejiang THOR Electric Co., Ltd |
|
Intelligent lightning protection box, three phase lightning protection, conflux box, distribution room elevator
Working principle of product
In the normal working condition, the lightning
protection module is in the disconnected state and does not affect
the normal work. When the line has the impulse overvoltage at the
moment when the lightning strikes, the lightning arrester module
quickly passes through the very short time, short the overvoltage
to the earth, and when the pulse overvoltage disappears, the
lightning arrester module is resumed to disconnect. State, which
does not affect the power supply of the user.
Product features
1. B+C level protection has high flow rate, low residual
pressure and fast response time.
2. adopt the latest arc extinguishing technology to
avoid fire.
3. The thermal protection circuit is adopted, and the
thermal protection is built.
Product specification
Model | TRSX-60 | TRSX-80 | TRSX-100 | TRSX-200 |
Rated Operating Voitage | 385 | 385 | 385 | 385 |
working voltage | 380 | 380 | 380 | 380 |
Working frequency (HZ) | 40~60 | 40~60 | 40~60 | 40~60 |
Voltage protection level (KV) | 1.8 | 1.8 | 1.8 | 1.8 |
Maximum flow rate (KA) | 60 | 80 | 100 | 200 |
response time | L-N 25NS N-PE
| |||
Protection mode | L-N/L,N-PE | |||
Terminal terminal | Maximum 35mm2 |
Brief introduction
The lightning protection box of the three-phase power
supply lightning protection box is equipped with power indication,
lightning protection indicator, deterioration alarm and indication,
lightning counter and lightning fuse. The SPD module is composed of
voltage switching module and voltage limiting module (or integrated
MOV). It is mainly installed in the distribution room, the
distribution cabinet, the AC distribution screen, the switch box
and other important equipment and the power supply line that is
easily struck by lightning equipment to protect the equipment from
the damage caused by the lightning overvoltage invaded along the
power line. It can be widely used in the main power supply of
communication, electric power, traffic, finance, railway, civil
aviation and other systems. Protection.
Use of attention
1. user units know the management system of lightning
protection facilities, and make special person management.
2. protector is applied to the lightning protection of the
main power distribution system C level, and is installed on the
incoming end of the main distribution cabinet, the distribution
cabinet or the terminal electric cabinet in parallel.
3. indoor outdoor operation
Product packaging:Carton packing
Transportation method
2. Trains, ships, aircraft transport