household short circuit overload protector, small air switch, DZ47 small circuit breaker.
Product description
DZ47 small circuit breaker is the current that can
connect, load and break normal circuit. A mechanical switch
electric appliance that can also be connected, carrying a certain
time and subsection current under the prescribed irregular
conditions, is mainly applicable to AC 50/60Hz, the rated voltage
is 230V/400V and below, the rated current to 63A.
Product features
1. band energy storage mechanism operation, contact close
fast
2. installation and use of convenient novice can also be
easy to install
3. core components are strictly screened, stable performance
and reliable operation.
Product specification
Name | TRS-DZ47 | |||
The number of poles | 1P | 2P | 3P | 4P |
Electric current | 10A/16A/20A/25A/32A/40A/50A/63A | |||
Voltage | 230/400V | |||
function | Short circuit / overload / isolation | |||
Product material | PC flame retardancy | |||
Connection mode | Fire line only | |||
Arc extinguishing mode | Vacuum circuit breaker | |||
Authentication | 3C |
Working principle of product
A small circuit breaker is the principle that the
bimetal bending is directed regularly with the increase of
temperature. When the circuit breaker is closed in normal working
condition, the internal bimetallic sheet is heated by a certain
current, and the thermal expansion coefficient of the two
bimetalles is different. It is not enough to release the release
mechanism. When the line appears general overload, when the
overload current is reached, the bimetallic sheet has a larger
bending angle and a lever in the release mechanism, which is enough
to push off the release mechanism, and from the small circuit
breaker, it plays the role of super load protection. The size of
the bimetallic strip is different from that of the small circuit
breaker.
Use of attention
1. the insulation resistance between the pole and pole
(except the monopole), the end and the outlet end of the circuit
breaker should be not less than 2M Omega, and the insulation
resistance between the pole and the shell, the pole and the
installation rail should not be less than 5M Omega. If the product
is not required, the product shall not be used and should be
exchanged in time with the supplier.
2. the setting temperature of the series circuit breaker is
30 +5 C. If a number of circuit breakers are loaded into the sealed
box at the same time, the temperature of the box is raised
correspondingly, and the current is 0.8In.
3. the circuit breaker needs to check contacts after
the circuit is short circuited. If the main contact burns seriously
or has pits, it needs to be repaired.
Company profile
Thor is all about protecting against the damaging
effects of power transients. It is our goal and mission to connect
our customer challenges with high-quality, right-priced solutions
and products – completed by unrivaled customer service and
technical support.
All types and classes of our lightning and surge arresters 20KA~200KA(8/20μS) and 15KA~50KA(10/350μS) are tested and pass all the requirements based on their class.
Product packaging:Carton packing
Transportation method
2. Trains, ships, aircraft transport