Zhejiang THOR Electric Co., Ltd |
|
Three phase power supply lightning protection box, 220V belt counter, elevator villa, power supply protection
Product introduction
The lightning protection box for single phase power
supply is designed according to the standard of IEC and GB. It is
equipped with power supply instructions, lightning protection
instructions, deterioration alarm and instructions, lightning
counter and lightning fuse wire. It is mainly installed in the
distribution room, distribution cabinet, AC distribution screen,
switch box and other important equipment, easy to be struck by
lightning equipment, in order to protect and set up. It is
protected against damage caused by lightning overvoltage along the
power line.
Product specification
Model | TRSX-60 | TRSX-80 | TRSX-100 | TRSX-200 |
Rated Operating Voitage | 385 | 385 | 385 | 385 |
working voltage | 380 | 380 | 380 | 380 |
Working frequency (HZ) | 40~60 | 40~60 | 40~60 | 40~60 |
Voltage protection level (KV) | 1.8 | 1.8 | 1.8 | 1.8 |
Maximum flow rate (KA) | 60 | 80 | 100 | 200 |
response time | L-N 25NS N-PE
| |||
Protection mode | L-N/L,N-PE | |||
Terminal terminal | Maximum 35mm2 |
Product features
1. application new clamping technique
2. use special impact melt sheet
3. lightning protection failure indication
Working principle of product
In the normal working condition, the lightning
protection module is in the disconnected state and does not affect
the normal work. When the line has the impulse overvoltage at the
moment when the lightning strikes, the lightning arrester module
quickly passes through the very short time, short the overvoltage
to the earth, and when the pulse overvoltage disappears, the
lightning arrester module is resumed to disconnect. State, which
does not affect the power supply of the user.
Use of attention
1. protector is applied to the lightning protection of the
main power distribution system C level, and is installed on the
incoming end of the main distribution cabinet, the distribution
cabinet or the terminal electric cabinet in parallel.
2. all wiring must be firmly and reliably connected
3. ground wire is less than 1 meters
Company profile
Thor is all about protecting against the damaging
effects of power transients. It is our goal and mission to connect
our customer challenges with high-quality, right-priced solutions
and products – completed by unrivaled customer service and
technical support.
Thor has been designing new products to meet the RoHS directive since 2006. Thor’s ongoing commitment to RoHS compliance includes continuing efforts to reduce the presence of hazardous substances in the design and manufacture of a growing number of popular products.