3/8" NBR Seals Unid Type Solenoid Water Valves Normally Closed AC110V DC12V 2W040-10 UD-10

Country/Region china
City & Province ningbo zhejiang
Categories Valves
InquireNow

Product Details

3/8'' NBR Seals Unid Type Solenoid Water Valves Normally Closed AC110V DC12V 2W040-10 UD-10

 

The shown is UNI-D type UD-10 solenoid valve, valve body is made of brass; armature assembly is made of stainless steel 304; solenoid coil is made of enameled copper wire; and the raw materials used are of high quality. The valve operation design is direct acting at zero pressure difference. The valve function is 2/2 way normally closed, so it is widely used in Pipeling water control, Water heater water supply, Air, Carwash, Coffee machines, Compressors, Fuel gases, Industrial automation, Industrial washing machines, Packaging, Steam, Thermoregulation, Vending, Water, Water treatment.

 

YouTube video of 3/8'' Uni-d Type Brass Body Electric Solenoid Valve:


 

Dimensions of 3/8 Inch 2S040-10 Solenoid Water Valves Normally Closed:

 

Details of UD-10 UNI-D Type NBR Seals Electric Solenoid Valve Water Air:

 

Specifications of 2W, UD & UW Series 2/2 Way NC Solenoid Valves:

Brando No2W025-062W025-082W040-102W160-102W160-152W200-202W250-252W350-352W400-402W500-50
Ref. NoUD-6UD-8UD-10UW-10UW-15UW-20UW-25UW-35UW-40UW-50
Working mediumAir, Inert Gas, Liquid, Vacuum
Valve type2/2 way, normally closed (NC)
Wetted Surface

Valve Body: Brass

Seals: NBR (Buna); Option: Viton (FKM)

Armature Assembly: Stainless Steel

OperationDirect Acting, Uni-Directional, Zero Differential
Port size1/8''1/4''3/8''3/8''1/2''3/4''1''1 1/4''1 1/2''2''
Operating pressure0 to 101 PSI / 0-0.7 Mpa (for Air, Water); 0 to 72 PSI / 0-0.5 Mpa (for Oil)
Operating temperatureMedia: -5 to 80°C (NBR Seal), -5 to 120°C (Viton Seal); Ambient: -5 to 45°C
Fluid viscosityBelow 20cst

 

Pipeline fluid controlling of Normally Closed Brass Solenoid Valve:

 

NORMALLY CLOSED valves OPEN when the coil is energized.
NORMALLY OPEN valves CLOSE when the coil is energized.

 

Seal Options: NBR: -5°C to 80°C, EPDM: -20°C to 120°C, VITON: -10°C to 150°C, PTFE: -10°C to 180°C.

 

ALL Standard valves are supplied with CONTINUOUS DUTY COILS of the proper class of insulation for the service indicated on the valve. The coil temperature may become hot after being energized for extended periods, but it is normal. Smoke or burning odor indicates excessive coil temperature and should disconnect the power to the coil immediately.

 

VOLTAGES: Standard: 12-24V DC and 24-110-220-230V/50-60 Hz AC. Voltage tolerances: +10% –5% for DC, +10%-15% for AC;

 

SERVICE LIFE: The service life of the solenoid valve depends on the operating conditions such as pressure, temperature, type of medium and the voltage. Normally the Brando solenoid valves are reliable for more than 1 million cycles.

 

Focus on your demands, Offer you best solution:

 

√ Contact us if some points you have doubt

√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for

√ Contact us if you are doing designing

 

Welcome to your any question and inquiry!

Hot Products

2W025-08 UD-8 1/4'' UNI-D Type Brass Solenoid Valve Direct Acting Normally Closed 24VDC 110VAC This ...
G 3/4 Inch Right Angle Dust Removal Solenoid Pulse Valve DMF-ZM-20 BFEC Type With Aluminum Alloy ...
1/2 Inch CA15T Goyen Type T Series Electromagnetic Pulse Valve With Threaded Connection AC 220V DC ...
3/8'' NBR Seals Unid Type Solenoid Water Valves Normally Closed AC110V DC12V 2W040-10 UD-10 The ...
1 1/4 Inch CA35T Goyen Type Right Angle Pulse Jet Dust Collector Valve With Threaded Connection AC ...
AC 110V DC 12V Medium Flow Double Diaphragm CA45T Goyen Type Pulse Jet Dust Collector Valve With ...