FAPC-LPTPS2 , LC To ST Singlemode Fiber Optic Jumper For Data Center With Low Insertion Loss

 

Fire Test And Fire Performance Of Fiber Optic Jumper And Pigtail

 

As we know, OFNR or OFNP is flame etardant mark for fiber optic jumper, they are with better fire performance than PVC and LSZH.

 

In the United States, Canada, Mexico and other North American countries, fire rating for copper cable is divided into four grades, CMX, CM, CMR, CMP and the fire rating of fiber cable is divided into three grades, OFN, OFNR, OFNP . These are specified in the UL standard, the CMR (OFNR) level is allowed to be used in the vertical trunk cable, CMP (OFNP) level is allowed to be direct laying in the ventilation pipe, and do not need to put into wire casing. CM (OFN) and CMX can be used for general cabling environments.

 

The international Europe standard defined low smoke halogen LSZH cable, the key point is the cable sheath material does not contain halogen, the smoke is low and with low toxicity when it is burning and the sight is not affected so people has a short time to escape. There are two standards, one is IEC332-1, flammability is quite similar to the North American CMX level cable, and the other is IEC332-2, flammability is equivalent to CM (OFN) level.

 

Low smoke halogen free substrates are polyolefins, which have a high fuel content, so they have to be mixed with metal hydrate fillers to inhibit their flammability, but when the water of hydration is exhausted, combustion may happen.

 

Under the same condition, fire spread speed is the same for bare CMX and LSZH cable, but there is no open fire for CMP (OFNP). CMX/T combustion test is to burn the CMX level cable which already put into metal pipe , the flame resistance is better than exposed cable . So put the cable into metal pipe during cabling is a good solution to higher the flameproof ability.

 

Main Features Of FAPC-LPTPS2


100% tested before shipping ( including end checking, Insertion Loss, customer specified length and Return Loss)
Default colour is Yellow , other customized colours are available upon request
outer jacket material is PVC or Low Smoke Zero Halogen (LSZH)
PC, UPC, APC polishing type are available
High concentricity 2.5mm ceramic ferrule for ST and 1.25mm ceramic ferrule for LC

Available fiber type G652B, G652D or G657A

With End A and end B markings

 

Product Specifications

 

ItemsSpecificationsItemsSpecifications
Fiber TypeSingle modeConnector Style

End A LC

End B ST

Polish or Ferrule Interface TypePC, UPCCable LengthsCustomized
Fiber Channel2Strength MemberAramid yarn
Outer Jacket MaterialPVC or LSZHOuter Jacket ColorYellow
Strength MemberE-glassOuter Jacket Diameter(mm)2.0mm x 4.1mm
Max. Crush1100 N/100mm2Tight buffer inside0.9mm
Min Bend Radius(Dynamic)mm20HMin Bend Radius(Static)mm10H
Maximum Tensile Load(Long term)100NMaximum Tensile Load(Short term)200N
Storage Temperature(°C)-20°C to 70°CInstallation Temperature(°C)-20°C to 70°C
Operating Temperature(°C)-20°C to 70°CThickness of jacketAbout 0.3mm

 

Hot Products

FAPC-SPTPM2 , SC To ST Duplex Fiber Optic Jumper Multimode Cable With Orange LSZH Jacket Production ...
FAPC-SPSPS2 , SC Duplex Fiber Optic Jumper Pass 3D Interferometer Test With Letter Cable Ring ...
FAPC-TPJPM2 , Dual Core MTRJ To ST Fiber Optic Jumper With Multimode Orange Optical Cable Optical ...
FAPC-SALPS2 , Single Mode G652 Fiber Optic Patch Cord Duplex With LC To SC Connector Main Technical ...
FAPC-LPTPS2 , LC To ST Singlemode Fiber Optic Jumper For Data Center With Low Insertion Loss Fire ...
FAPC-LPLPM2 , Multimode Duplex Fiber Optic Jumper With Orange Fiber Cable And LC Connector Fiberall ...