Results foraloka 4d probe repairfrom 1959 Products.
|
GE Logiq E9 Ultrasound Probe ML6-15-D Linear Vascular Transducer Repair 1. Type: Linear 2.Compatible system: Logiq E9, Logiq S8, Vivid E9, Voluson E8 Expert 3. Frequency: 4.5-15 ...
|
|
|
|
4D probe Medical Equipment Accessories Endoscopy IPC power system touch screen Business Scope B Ultrasound Probe Repair Range Probe Detection, acoustical lens replacement, sound ...
|
|
|
|
GE Logiq E9 ML6-15-D Breast Ultrasound Probe Repair Linear Vascular Transducer 1. Type: Linear 2.Compatible system: Logiq E9, Logiq S8, Vivid E9, Voluson E8 Expert 3. Frequency: 4...
|
|
|
|
GE C1-5-D Ultrasound Probe Repair Strain Relief Lens Replacement Model: GE C1-5-D Fault Phenomenon: about 3 images of the machine are missing, the image will be missing while ...
|
|
|
|
Motor Repair GE RAB2-5-D 4D Probe Motor Control Failures Motor control failures If the array stops moving or gets stuck, the motor control function has failed and may need to be ...
|
|
|
|
GE IC5-9-D Ultrasound Probe Repair Crystal Array Replacement Model: GE IC5-9-D Fault Phenomenon: The connector cable is aging and discolored, the housing cover is worn and ...
|
|
|
|
Probe Maintenance for GE 4C Ultrasound Transducer Lens Replacement Model: GE 4C Fault Phenomenon: The cable and strain relief are aging, the image on the computer has dark shadows, ...
|
|
|
|
GE Logiq 9 Ultrasound Probe 4C Convex Array Transducer Medical Use 1. Type: Convex 2.Compatible system: Logiq 5 Pro, Logiq 7, Logiq 9, Logiq A5, Logiq P5, Logiq P6, Logiq P7, Logiq ...
|
|
|
|
GE M5SC-D Ultrasound Transducer Crystal Array Replacement Cable and Strain Relief Repair Model: GE M5SC-D Fault Phenomenon: Cable and strain relief are aging, lens bubbling. ...
|
|
|
|
GE L4-12T-RS Ultrasound Transducer Lens Replacement Model: GE L4-12-RS Fault Phenomenon: Cable and strain relief are aging, lens bubbling. Maintenance Plan: Replace lens (the ...
|
|
|
|
Ultrasound Transducer Repair Service GE 8C-RS Acoustic Lens Replacement Model: GE 8C-RS Fault Phenomenon: The connector cable and strain relief are aging, the image on the computer ...
|
|
|
|
Probe Maintenance for GE IC5-9-D Ultrasound Transducer Replace the Original Crystal Model: GE IC5-9-D Fault Phenomenon: The cable is aging and discolored, the housing cover is worn ...
|
|
|
|
Probe Maintenance for Philips L12-3 Ultrasound Transducer Strain Relief/Crystal and Connector Cable Replacement Model: Philips L12-3 Fault Phenomenon: The cable and strain relief ...
|
|
|
|
Biosound Biosound CA123 Ultrasound Transducer Probe Replace Crystal Model: Biosound Biosound CA123 Fault description: The image on the machine is seriously missing and the crystal ...
|
|
|
|
Siemens 18L6 Linear Array Ultrasound Transducer Probe Lens Replacement Model: Siemens 18L6 Fault description: The cable is yellow, the image on the computer has dark shadows, and ...
|
|
|
|
GE RIC5-9W-RS 4D Monitor Strain Relief Repair Service Ultrasound Probe 1. Type: Microconvex 2.Compatible system: Voluson i, Voluson e, Voluson S8, Voluson S10, Logiq S6 , Logiq P6 ...
|
|
|
|
Siemens 18L6 Ultrasound Probe Repair Service Crystal Array Replacement Model: Siemens 18L6 Fault Phenomenon: The cable is yellow, the image on the machine has a dark shadow, and ...
|
|
|
|
Repair 4D Samsung V5-9 Strain Relief Among the more common issues is a crack or separation in the strain relief. This problem occurs most often where the probe attaches to the ...
|
|
|
|
Repair 3D/4D GE RAB4-8-D Crystal/Crystal Replacement/Broken Probes Crystal damage -Weak, dead, or damaged crystals Very often the cause of crystal damage in ultrasound probes is ...
|
|
|
|
Biosound Biosound SL1543 Linear Array Ultrasound Transducer Probe Replace Lens and Crystal Model: Biosound SL1543 Fault description: The lens is broken, the capacitor is grounded ...
|
|
|
You may also be interested in :