Home Companies Guangzhou Rongtao Medical Tech LTD.

GE 4C-RS Ultrasound Probe Repair Crystal Replacement Imagine Problem

Guangzhou Rongtao Medical Tech LTD.

Contact Us

[China] country

Trade Verify

Address: Room 1705,Office Building B1,Wanda Plaza,No.2707,Kaichuang Road,Guangzhou,Guangdong,China

Contact name:MileyZhu

Inquir Now

Guangzhou Rongtao Medical Tech LTD.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

GE 4C-RS Ultrasound Probe Repair Crystal Replacement Imagine Problem

Country/Region china
City & Province guangzhou guangdong
Categories Advertising Screens
InquireNow

Product Details

 

Repair GE 4C-RS Ultrasound Probe Repair Crystal Replacement Imagine Problem

 

 

Crystal damage -Weak, dead or damaged crystals

 

Very often cause of crystal damage in ultrasound probes is dropping of probe on the floor or hitting of probe with gel bottle or other object. Once a probe is dropped its piezoelectric crystals may stop sending or receiving signals, resulting in scans with weak or dead elements. This leads to black lines in an image, these lines are called dropouts. Weak elements cause the faint little lines that don’t obscure much. These are the first signs that the elements are getting progressively damaged and need to be replaced. Instead of faint lines if the lines are thick and pronounced, the elements are dead. If there are thick lines in the scanned image, important things can be missed out during diagnosis. You may be harming the patient due to misdiagnosis.

 

Solution

 

Repair/Replace the Crystal

 

 


 

 

 

Other hot GE models we can repair:

 

GEC1-5-D
GEC1-5-RS
GE4C
GE4C-RS
GE4C-A
GE4C-D
GE4C-SC
GEE8C/E8C-RS
GEE8CS
GERIC5-9-D
GE3CRF-D
GEC1-6-D
GERAB4-8-RS
GERAB2-5-RS
GE6S-RS
GE12L-RS
GE3SC-RS
GEL6-12-RS
GE11L
GE11L-D
GE12L-RS
GE8C
GE3S
GE3S-RS
 

 

 

 

Common ultrasonic Probe Damage(Convex, Linear, Sector, Endocavity probes)

 

Common ultrasonic probe damageSolutions
Lens damage, wear, holes, swelling, delaminationLens replacement
Strain relief damage, separationStrain replacement
Nosepiece and probe separation and cracks

Cosmetic repairs

Cable cutsCable patches, possible cable replacement
Connector housing electrical damageMajor and minor electrical repairs, pin module replacement

 

 

 
Probe Troubleshooting Summary
 
1.Check whether multiple probes are the same phenomenon, sometimes it is necessary to plug again
2.Lens and crystal failure are sometimes similar, both are shadowing on the image
3.If there is a single probe problem, replace the socket to have a check.
4.The high frequency probe (small parts probe) is sensitive. If only this probe doesn’t work, may be caused by machine failure.

 

Hot Products

Repair GE 3S-RS​ Pin/Repair Connector/Broken Pins/Locking Shafts​ Probe connectors are the piece of ...
Samsung V5-9 Ultrasound Probe Repair Oil and Sealing Problem Oil leakage Probe Troubleshooting ...
Repair GE 4C-RS Ultrasound Probe Repair Crystal Replacement Imagine Problem Crystal damage -Weak, ...
Damaged Cable Repair Strain Relief Replacement Ultrasound Probe GE 4C-D Cable leakage failure reason ...
GE 3S-RS Replace Lens 3D 4D Probe Repair Ultrasound Sensor Repair time: 2-5 days Warranty: 60 days ...
Medical Ultrasound System GE Voluson E6/Personal Sonogram Machine/Picture Ultrasound 1. Condition: ...