EPIQ 7 Ultrasound Machine Repair

Country/Region china
City & Province guangzhou guangdong
InquireNow

Product Details

 
EPIQ 7 system reports error "511"
 
 
 
 

Failure phenomenon


The EPIQ 7 Ultrasound was suddenly powered off during use, and then suddenly powered off after it was powered on. After encountering two sudden power failures, it turned on again. An abnormal startup failure occurred. The display stayed on the "" interface for a long time, and finally entered the boot interface. Error "511" is reported, and the device cannot be used normally.
 

 


Failure analysis and Trouble shooting


According to the description of the operator, re-plug the main power cord of the EPIQ7 ultrasound and press the power button to turn it on. It is found that the interface that the display stays on for a long time is the BIOS detection interface (see the figure below). Restart into the BIOS interface and check that the BIOS settings do not appear The problem, according to the BIOS test, is only for the self-test of the front end of the EPIQ7 when it is turned on. Therefore, if there is a problem with the front end of the device, it is suspected that the fault should occur outside the front end.
 


Unplug the ACQ and power REG PCB from the back-end PC, remove all the front-end load, and leave only the PC part. It is found that the fault remains, and it is determined that the fault should lie in the PC part.
 


Enter the boot interface and report the error "511", check the error log and find the message "Plantform Monitor failed to start the Digital Media Manger process", which means that some components have failed to start, so it is necessary to find the failed components to determine whether it is the root cause of the failure.
 


Remove all the circuit boards and cables connected to the PC motherboard, leaving only the hard disk, memory and graphics card. After restarting the EPIQ7 ultrasound, it was found that the BIOS detection interface was quickly completed, and the system was turned on normally without an error, and the fault was eliminated.
 


It is judged that the damaged parts are among the parts that were just removed. Insert the parts that were just removed one by one each time and then restart the device. It was found that the fault recurred after the DVD cable was plugged into the motherboard. The fault still exists after replacing the DVD cable. The DVD damage caused the EPIQ7 failure. After replacing the DVD, the EPIQ7 is normal, and it can be used again.

 

 

 

 

Ultrasound parts that we can repair:

 

Repair List of Featured Ultrasonic Board & Assy
BrandSystemDescriptionPart Number
GELogiq P5CPU mainboard5168431
GELogiq P6CPU mainboard 
GELogiq E9/vivid E9GFI25161631
GEVoluson E6/Voluson E8RSRKTI301394-2/KTI196357
GEVoluson E6/Voluson E8RFI/ RFI21b BoardKTI300614/KTI302197-6
GEVoluson S6/S8/P8BF645396937-2
GEVoluson S6/S8/P8RFS board5364098-2/5364098-3
GEVoluson S6/S10/P8BF192 board5357234
AlokaAlpha 5mainboardEP493700DD
AlokaAlpha 6RX Beam FormerEP555501AA
AlokaAlpha 6CW boardEP555700
AlokaAlpha 6CPU mainboardEP537000/EP563000
AlokaAlpha 6TX/RXEP555300
AlokaAlpha 6/Alpha 7DOMEP550000AA
AlokaAlpha 10RX Beamformer boardEP531800CE
AlokaAlpha 10wave generator BoardEP495000HH/EP495000HJ/EP495000FF
HitachiF37TX/RSEP557400/EP557300
HitachiF37mainboardEP575700BC/EP560800
AlokaF75USP boardEP556600
AlokaF75Cell BoardEP558800
HitachiHI VISION AviusRDBF board7513907A/7513612
HitachiArietta 60CELLEU-9160C
HitachiArietta 70TXEP572300AA
HitachiArietta 70CELL 
HitachiNoblusCELL 
HitachiNoblusCONT-B 
HitachiAscendusCELL7352830A
SiemensX150/G40BE10131804
SiemensX300BE 2.0/BE 3.0/BE 7.510131990
SiemensX700BE10136465
SiemensX700RC10136467
SiemensX700TI11014292
SiemensAntaresBE7472421
SiemensAntaresCB7288504
SiemensS2000RM30010852163
SiemensS2000 high version/S3000RM30110854749
iU22/iE33EMB excelsior motherboard453561419431/453561382231/453561419431
iU22/iE33UMB Unified Motherboard453561254492/453561360251
HD15ACB acquisition control board453561197145/453561197144
HD15AIM board4.53561E+11
CX50control panel4.53562E+11
CX50mainboard453561368033/453561622163/453561495832
Affiniti 70ACQ acquisition control board 
EPIQ 5/EPIQ 7ACQ Acquisition Module board453561734844/453561704246
BiosoundMylab SeriesCPU mainboard9501361000
ToshibaAplio 300/400/500mainboardPM30-38696
ToshibaAplio 500RXywm2056*a
ToshibaXario 200TXPM30-32732-1
ToshibaXario 200RXPM30-32733-1
Remarks
1.The repair cycle is within 3-5 days.
2.Warranty after fixed:60 days.
3. Kindly send us the estimated main faults (better to have image) for our engineer to prejudge.
4.Package price is available if repair 3 pcs or more at one time.
5.Extra discount for VIP partners.
6.You could have different part No.under same description.

 

 

Hot Products

GE Logiq P6 Color Ultrasonic Fault Maintenance 1. The fault phenomenon After reading the tags, you ...
EPIQ 7 system reports error "511" Failure phenomenon The EPIQ 7 Ultrasound was suddenly powered off ...
GE 3.5C Convex Array Ultrasound Transducer 1. Type: Convex Array 2. Frequency: 2.0-5.0MHz 3. ...
GE 3C Convex Ultrasound Probe Transducer 1. Type: convex array 2. Frequency: 2.1-5.7 Mhz 3. ...
GE 3CRF Micro-convex Ultrasound Transducer 1. Type: Micro-Convex array 2. Frequency: 1.0-5.0 MHz 3. ...
GE 3CRF-D Broadband microconvex Ultrasound Transducer 1. Type: micro-convex 2. Frequency: 1.0-6.0 ...