GE RAB4-8-D Wideband Convex Array Ultrasound Probe Medical Scanner

Country/Region china
City & Province guangzhou guangdong
Categories Beauty Products Agents
InquireNow

Product Details

 

GE RAB4-8-D Wideband Convex Array Ultrasound Probe Medical Scanner

 

1. Type: curved array
2. Frequency: 2-8 MHz
3. Compatible system: logiq e9/voluson e6/voluson e8
4. Application: abdominal, obstetrics, and gynaecological
5. Condition: original, in good working condition
6. With 60 days warranty

 

 

 

 

 

 

 

GE Ultrasound System
LOGIQ P5, LOGIQ P6, LOGIQ S7, LOGIQ S8, VOLUSON 730, VOLUSON 730 PRO, VOLUSON 730 EXPERT, VOLUSON S8, VOLUSON P8, VOLUSON S6, VOLUSON S20, VOLUSON P8, VOLUSON E10, VIVID E9, LOGIQ BOOK, LOGIQ 5, LOGIQ 7, LOGIQ 9, LOGIQ E9, LOGIQ F6, LOGIQ F8, VIVID I, VIVID Q, VOLUSON I, VOLUSON E, VIVID S5, VIVID 3, VIVID 7...

 

 

 

Common ultrasonic Probe Damage(Convex, Linear, Sector, Endocavity probes)

 

Common ultrasonic probe damageSolutions
Lens damage, wear, holes, swelling, delaminationLens replacement
Strain relief damage, separationStrain replacement
Nosepiece and probe separation and cracksStrain replacement
Cable cutsCable patches, possible cable replacement
Connector housing electrical damageMajor and minor electrical repairs, pin module replacement

 

 

 

 

Knowledge Point

 

 

**Color Doppler Flow Imaging:**

The Color Doppler flow imaging system is designed to simultaneously present B-type images and Doppler blood flow data, revealing information about blood flow direction, velocity, and dispersion. The dual ultrasound scanning system is instrumental in this process. The Color Power Angio (CPA) component detects the backscattered energy of blood cells without distinguishing the flow direction, independent of the angle θ (the angle between the direction of the sound wave and the blood flow direction). While CPA enhances the sensitivity of blood flow detection, especially for low-speed blood flow in small vessels, it does not provide information about the direction of blood flow.

 

**Harmonic Imaging:**

Harmonic imaging capitalizes on the non-linear propagation of ultrasound through body tissues. By emitting sound waves at a frequency of f0, the resulting echo frequencies include f0 (fundamental wave), 2f0, 3f0, and so forth. The second harmonic (2f0) holds the highest energy. Ultrasonic Harmonic Imaging (UHI) relies on the information carried by the second harmonic in echoes, with or without the use of Ultrasound Contrast Agents (UCAs). Harmonic imaging without UCAs is termed native harmonic imaging or tissue harmonic imaging, while the use of UCAs is referred to as contrast harmonic imaging.

 

**Daily and Long-Term Storage of Ultrasound Transducers:**

 

1. Transducers should be stored in the designated holders on the ultrasound system or a securely mounted wall rack when not in use.

2. Ensure that the transducer holders are clean before storing transducers.

3. When storing transducers, use cable-management clips, if available, to secure the transducer cable.

4. Avoid storing transducers in areas with extreme temperatures or direct sunlight.

5. Transducers should be stored separately from other instruments to prevent inadvertent damage.

6. Before storing, ensure that transducers are thoroughly dry.

Hot Products

GE 3SP-D Wideband Phased Array Convex Ultrasound Transducer Probe 1.Type:phased array 2.Frequency: 1...
GE 4C Convex Array Ultrasound Transducer Used Probe Use in Hospital Diagnosis Machine 1.Type: convex ...
Aloka UST-979-3.5 Ultrasound Transducer Probe ultrasound probe repair Model: ALOKA UST-979-3.5 Fault ...
GE RAB4-8-D Wideband 2-8MHz Convex Array Ultrasound Probe for Abdomen,Obstetrics & Gynaecological ...
GE RAB4-8-D Wideband Convex Array Ultrasound Probe Medical Scanner 1. Type: curved array 2. ...
GE Ultrasound Probe for Voluson S6/S8, 2-5 MHz, Abdominal/OB/GYN/Pediatrics/Vascular 1. Type: convex ...