Aloka UST-979-3.5 Ultrasound Probe Repair Troubleshooting Ultrasound Device

Country/Region china
City & Province guangzhou guangdong
Categories Veterinary Instrument
InquireNow

Product Details

 

Aloka UST-979-3.5 Ultrasound Transducer Probe ultrasound probe repair

 

  •  Model: ALOKA UST-979-3.5

  •  Fault Phenomenon: The cable is wrapped with tape, the cable is yellow and damaged, the strain relief is aged, and there are gaps and cracks in the connector housing, and the lens is damaged.

  •  Maintenance Plan: Replace the lens and connector housing. (The matching layer needs to be dismantled for lens inspection)

 

 

 

2D Probe Repair
Service BrandGE,,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound,Sumsang Medison
Service TypeLinear,Convex,Phased,Sector,Endocavity
Repair RangeMembrane/lens replacement,Strain relief replacement,Electronic connector repair,Crystal/Array replacement,Plastic housing repair,Connecting cable repair

 

 

 

Common ultrasound Probe Damage(Specialty 3D/4D Volume probes)

 

Common ultrasound probe damageSolutions
Lens cap damageLens cap replacement
Fluid and oil leaksLens cap replacement, oil reservoir repair and replacement
Cable cutsCable patches, possible cable replacement
Inoperative steeringMotor repair
Connector housing electrical damageMinor electrical repairs, pin module replacement
Weak or dead elements, dropouts in an imageArray ball replacement, oil reservoir repair and replacement

 

 

 

Warnings and cautions of ultrasonic probe

 

The ultrasonic probe is a valuable device. It must be careful in the process of use. Avoid dropping, impact, or abrasion to transducers.

When installing or removing the probe, first switch off the power and then operate it carefully.

Avoid rapid and extreme temperature changes, as well as lengthy exposure to direct sunlight or a strong ultraviolet light source.

Do not use sharp objects to penetrate the acoustic lens.Once the acoustic lens is damaged, the coupling gel is easy to enter the interior of the probe and damage the piezoelectric element.

Do not soak transducer in any liquid above the recommended level as stated in the user manual for your system, please operate according to the manufacturer's instructions, otherwise it will lead to circuit failure or even burn out.

Do not disinfect at high temperature, because the probe is equipped with piezoelectric ceramics, high temperature will weaken the effect.

Before use, carefully check whether the housing and cable are damaged, so as to prevent the probe from high voltage injury.

After the probe is used, the residual coupling gel on the probe must be wiped clean to prevent rats or other animals from gnawing the lens.

 

 

 

Picture

 

 

 

 

 

Hot Products

GE C1-6-D Probe Convex Ultrasound Transducer 1. Type: Concvex 2. Frequency: 5-6.0 MHz 3.Compatible ...
Pediatric Ultrasound Probe GE 9L-D Ultrasound Transducer Probe 1. Type: linear 2. Frequency: 3.1-7...
GE 3SP-D Wideband Phased Array Convex Ultrasound Transducer Probe 1.Type:phased array 2.Frequency: 1...
GE 4C Convex Array Ultrasound Transducer Used Probe Use in Hospital Diagnosis Machine 1.Type: convex ...
Aloka UST-979-3.5 Ultrasound Transducer Probe ultrasound probe repair Model: ALOKA UST-979-3.5 Fault ...
GE RAB4-8-D Wideband 2-8MHz Convex Array Ultrasound Probe for Abdomen,Obstetrics & Gynaecological ...