Home Companies Sinuo Testing Equipment Co. , Limited

Rapid Temperature Cycling Test Chamber 800L -70℃~180℃ IEC 60068-2-78 Temperature Test

Sinuo Testing Equipment Co. , Limited

Contact Us

[China] country

Trade Verify

Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China

Contact name:Zoe Zou

Inquir Now

Sinuo Testing Equipment Co. , Limited

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Rapid Temperature Cycling Test Chamber 800L -70℃~180℃ IEC 60068-2-78 Temperature Test

Country/Region china
City & Province guangzhou guangdong
Categories Other Measuring & Analysing Instruments
InquireNow

Product Details

 

Rapid Temperature Cycling Test Chamber 800L -70℃~180℃ IEC 60068-2-78 Temperature Test

 

Product information:

 

This test equipment is suitable for: adaptability testing of electricians, electronic products, components, parts and materials when they are stored, transported and used in high and low temperature environments.

This testing equipment prohibits: testing of flammable, explosive, and volatile substance samples, storage of corrosive substance samples, storage of biological samples, or storage of samples with strong electromagnetic emission sources.

 

Standards:

 

IEC60068-2-1:2007 Low temperature test method Ab

IEC60068-2-2:2007 High temperature test method Bb

IEC60068-2-78:2007 Constant damp heat test method Cab

 

Technical parameters:

 

Volume, dimensions, and weight

Volume

800L

Inner chamber dimensions

W1000mm×H1000mm×D800mm

Outer chamber dimensions

W1250mm×H2170mm×D2250mm

Weight

1400 kg

Performance

Test environment conditions

When there is no sample in the test chamber, the ambient temperature is +25°C and the relative humidity is ≤85%.

Test methods

GB/T 5170.2-2008 Temperature test equipment

GB/T 5170.5-2008 Damp heat test equipment

Temperature range

-70℃~180℃

Temperature fluctuation

≤1.0℃

Temperature uniformity

≤2.0℃

Temperature deviation

≤2.0℃

Heating rate

-60℃→+150℃ 15℃/min (average over the whole process)

Cooling rate

+150℃→-60℃ 15℃/min (average over the whole process)

Load

50KG

Humidity range

 

(10~98) %RH (refer to the temperature and humidity controllable range chart, no active heat load)

Relative humidity deviation

 

±3.0%RH (when humidity>75%RH)

±5.0%RH (when humidity ≤75%RH)

Meet test standards

GB/T5170.2-2008 Temperature test equipment

GB/T5170.5-2008 Damp heat test equipment

GB/T2423.1-2008(IEC60068-2-1:2007) Low temperature test method Ab

GB/T2423.2-2008(IEC60068-2-2:2007) High temperature test method Bb

GB/T2423.3-2006(IEC60068-2-78:2007) Constant damp heat test method Cab

Structural characteristics

Insulation envelope structure

Outer wall material: high-grade cold-rolled steel plate, surface spray treatment (FQY standard color)

Inner wall material: stainless steel plate SUS304

Box insulation material: rigid polyurethane foam + fiberglass

Door insulation material: fiberglass

Air conditioning channel

Centrifugal fans: 4, AC380V 550W

Heater, evaporator (also dehumidifier), water supply and drainage outlet, dry bulb temperature sensor, humidifier, dry burn preventer, electronic humidity temperature sensor, wet bulb water tank

Standard configuration of test chamber

Observation window: 1 piece of transparent electric heating film hollow tempered glass (located on the door), visual range is about 500mm×600mm

Lighting: 11W/AC220V 1 piece

Mobile casters: 4 pieces

Sample rack: 2 layers of stainless steel sample rack, load-bearing (evenly distributed): 50kg/layer

Lead hole

There are 2 test lead holes on both sides of the box (1 on each side), and the test lead holes are equipped with 4 soft plugs in total

Door

 

Single hinged door (left hinge, right handle), equipped with observation window, lighting, window frame/door frame anti-condensation electric heating device

Control panel

Controller display, over-temperature protection setter, USB interface, fault light

Mechanical room

Refrigeration unit, drain pan, drain hole

Power distribution control cabinet

Distribution boards, distribution panels, exhaust fans

Heater

Nickel chromium alloy electric wire heater

Heater control mode: contactless equal period pulse width modulation, SSR (Solid State Relay)

Heater power: 6kW×3

Humidifier

 

Shallow water tray humidification method humidification method

Stainless steel armored heater

Heater control mode: contactless equal period pulse width modulation, SSR (Solid State Relay)

Water level control device, heater anti-dry device

Humidifier power: 6KW×3

Water source

Humidification water supply system

Power cord hole and drainage hole

Located on the back of the box

Refrigeration system

Working method

Mechanical compression binary cascade refrigeration method

Cooling method

Water cooling

Refrigeration compressor

Semi-hermetic low-noise piston compressor

Evaporator

Fin tube heat exchanger (also used as dehumidifier)

Condenser

Shell and tube heat exchanger/casing heat exchanger

Throttle device

Thermal expansion valve, capillary tube

Evaporative condenser

Stainless steel brazed plate heat exchanger

Refrigerator control method

The PLC (Programmable Logic Controller) of the control system automatically adjusts the operating conditions of the refrigerator according to the test conditions.

Evaporator pressure regulating valve (to prevent evaporator freezing).

Compressor return air cooling circuit.

Environmentally friendly refrigerant

R404a/R23 (ozone depletion index is 0)

Electrical control system

 

Controller model

TEMI 2700
Function introductionThe controller system mainly consists of 2 parts. That is, the LCD control panel and the input/output control board (I/O board). The LCD controller displays the cause and solution of the fault in Chinese characters based on the alarm signal transmitted through communication to the I/O board. Users can choose between English menu and Chinese menu according to their needs. LCD controller has built-in lithium battery and calendar clock. It has the functions of power outage protection and scheduled power on/off.
Monitor7.0-inch 640×480 dot matrix, TFT color LCD display
Operation modeProgram mode, fixed value mode
Setting methodEnglish menu, touch screen input
Program capacity

Editable: 20 programs. Each program has a maximum of 50 steps and can be set to 20 cycles (each cycle step has a maximum of 9999 cycles)

Fixed: 10 procedures

The program can be linked to achieve unlimited operation.

Setting range

Temperature: Adjust according to the temperature working range of the equipment (upper limit +5℃, lower limit -5℃)

Humidity: (0~100)%RH (temperature and humidity test equipment)

ResolutionTemperature: 0.1℃; Time: 0.1min; Humidity: 0.1%RH (temperature and humidity test equipment)
InputThermocouple (platinum resistance/voltage/current, etc., according to equipment needs)
Communication function

RS-485 interface, with local and remote communication functions (needs to be equipped with centralized monitoring software, RS-485/RS-232 converter, and needs to occupy one COM port and one USB port of the PC). Up to 16 devices can be connected at the same time, with a maximum cumulative cable length of 800m.

PC software usage environment: IBM PC compatible machine, PⅡ or above CPU, 128M or above memory, English Windows2000 or English WindowsXP operating system.

Control method

Anti-integral windup PID

BTC balance temperature control method (temperature test equipment)

BTHC balanced temperature and humidity control method (temperature and humidity test equipment)

Curve recording function

It has SRAM with battery protection, which can save the device's setting value, sampling value and sampling time. You can touch the screen with your finger to slide and observe the data in real time.

The default maximum storage time is 60 days (when the sampling period is 1.5min). The sampling period can be set by the user. The sampling time calculation formula is as follows:

If the sampling period is set to t min, the storage time: d=((65536xt)/60)/24 (days)

Test data collection

1. Screen interface curve output---directly save the curve interface on the touch screen or any interface required by the customer as a *.bmp picture to a U disk or directly use a printer to print the curve interface on the touch screen or customer requirements (interface software needs to be changed) any interface.

2. USB function---equipped with 1 8G U disk. During the test, insert the U disk into the USB interface of the controller, and the test data will be automatically recorded into the U disk and saved as a *.csv data file (not a graph). The sampling period can be set on the screen. It can be opened and processed using EXCEL and other software.

3. Connect to the printer (optional): --- Configure the printer to print the test date, set temperature, measured temperature, set humidity, and measured humidity by setting the number of prints according to time.

4. Connected to PC (optional): ----Through the centralized monitoring software, test data can be recorded, automatically displayed as a curve in the PC, and can be printed directly, with no limit to the recording time. File size depends on hard drive capacity. The PC can also be used as an operating terminal to achieve remote monitoring.

Input/output control panel (I/O panel)

Input characteristics:

24 photoelectrically isolated 24V switching inputs. The I/O board periodically scans 24 switches to understand the real-time operating status of the equipment and the status of the equipment protection device. 5 analog photoelectrically isolated input channels. The analog channel can be connected to K and T-type thermocouples, Pt100 platinum resistance, 0~10V DC voltage source, 0~20mA, 4~20mA current source input.

Output characteristics:

20 relay outputs with photoelectric isolation. (Soil: 24VDC, Contact: 5A, 250VAC, 5A, 30VDC). 4 transistor outputs with photoelectric isolation. It can directly drive the solid state relay with 24VDC as the control end. The temperature and humidity recorder can be used by connecting a third-party manufacturer's D/A module (standard DC 4~20mA output) to the RS-485 bus that communicates with the LCD controller.

Programmable logic control:

The I/O board has built-in programmable logic control and has the functions of a PLC. This makes the I/O board more powerful than an ordinary pure input/output board, making it easy and convenient to change the logic control method and expand the I/O board. The program can be flexibly changed according to the user's special requirements through the PC, downloaded and solidified on the I/O board.

Communication function:

The I/O board has an isolated RS-485 communication interface. Through this communication interface, the I/O board sends analog and switching input and output values to the LCD control panel for calculation and display. And accept control commands from the LCD control panel.

Additional featuresFault alarm and cause, processing prompt function. Power failure protection function. Upper and lower limit temperature protection functions. Timing function (automatic start and automatic stop), self-diagnosis function.

Temperature and humidity measurement

Temperature: Armored T-type thermocouple or PT100

Humidity: Classic wet and dry bulb thermometer method (damp heat type)

 

Hot Products

IEC 60335-2-84 Cushion Internal Wire Bending Testing Machine Household Appliance Test Product ...
UL 496 Metal Shell Lamp Holder Safety Test Appratus LED Lampholder Testing Equipment Product ...
IEC 60068-2-14 Three-Box Thermal Shock Test Chamber 300L Environmental Test Chamber Product ...
IEC 60529 IP5X/IP6X Walk-In Sand And Dust Test Chamber 24 CBM For EV Charging Station Product ...
IEC 60529 IP5X/IP6X 24 CBM Walk-In Sand And Dust Test Room Ground Embedded Type Product Information: ...
Rapid Temperature Cycling Test Chamber 800L -70℃~180℃ IEC 60068-2-78 Temperature Test Product ...