Shanghai Schneider-Sunshine Mechanical Group Co.,Ltd. |
|
0.6~1.1m³/min Two Stage Screw Air Compressor 7.5KW Air Cooling
Air intake status | ≤Ambient temperature intake pressure 1.013bar(A) | Voltage(V) Frequency(Hz) | 380V50Hz |
Start-ups | Y-△ | Noise dB(A) | 72±5dB |
Oil Content | 1~3ppm | Outlet Air Temperature | ambient temperature+8℃ |
We may provide all kinds of invert screw air compressor, the power
from 5.5kw to 560kw,the air delivery from 0.4m³/min to 100m³/min,
the working pressure from 0.7mpa to 1.3mpa, and with water cooling
,air cooling, belt drive or direct connecting.
⊙ Type air compressor pause
Specifacation | Cooling Style | Air Capacity (m³/min) | Discharge Pressure (bar) | Motor Power (kw) | Speed (r/min) | Voltage(V) Frequency(Hz) | Cooling Air Capacity (m3/min) | Joint pipe Size (inch) | Total Weight (kg) | Dimension(L*W*H) (mm) |
SRC-7.5SA | Air cooling | 0.85 | 7 | 5.5 | 2980 | 380V50Hz | 80 | 1/2″ | 230 | 850*735*990 |
0.8 | 8 | |||||||||
0.6 | 10 | |||||||||
0.4 | 13 | |||||||||
SRC-10SA | Air cooling | 1.1 | 7 | 7.5 | 2980 | 380V50Hz | 80 | 1/2″ | 410 | 850*735*990 |
1 | 8 | |||||||||
0.8 | 10 | |||||||||
0.6 | 13 | |||||||||
SRC-15SA | Air cooling | 1.7 | 7 | 11 | 2980 | 380V50Hz | 80 | 1/2″ | 475 | 1100*750*1150 |
1.6 | 8 | |||||||||
1.4 | 10 | |||||||||
1.2 | 13 | |||||||||
SRC-20SA | Air cooling | 2.4 | 7 | 15 | 2980 | 380V50Hz | 100 | 1″ | 560 | 1350*850*1150 |
2.2 | 8 | |||||||||
2.1 | 10 | |||||||||
1.7 | 13 | |||||||||
SRC-25SA | Air cooling | 3.1 | 7 | 18.5 | 2980 | 380V50Hz | 145 | 1″ | 580 | 1350*850*1150 |
2.9 | 8 | |||||||||
2.7 | 10 | |||||||||
2.2 | 13 | |||||||||
SRC-30SA | Air cooling | 3.8 | 7 | 22 | 2980 | 380V50Hz | 145 | 1″ | 640 | 1350*850*1150 |
3.5 | 8 | |||||||||
3.2 | 10 | |||||||||
2.7 | 13 | |||||||||
SRC-40SA | Air cooling | 5.2 | 7 | 30 | 2980 | 380V50Hz | 255 | 1″ | 900 | 1350*850*1150 |
5 | 8 | |||||||||
4.3 | 10 | |||||||||
3.7 | 13 | |||||||||
SRC-50SA | Air cooling | 6.4 | 7 | 37 | 2980 | 380V50Hz | 255 | 1½″ | 980 | 1550*950*1450 |
5.9 | 8 | |||||||||
5.5 | 10 | |||||||||
4.8 | 13 | |||||||||
SRC-60SA | Air cooling | 8 | 7 | 45 | 2980 | 380V50Hz | 255 | 1½″ | 1050 | 1550*950*1450 |
7.7 | 8 | |||||||||
7 | 10 | |||||||||
5.8 | 13 | |||||||||
SRC-75SA | Air cooling | 10.5 | 7 | 55 | 2980 | 380V50Hz | 268 | 2″ | 1250 | 1900*1240*1700 |
9.8 | 8 | |||||||||
8.7 | 10 | |||||||||
7.5 | 13 | |||||||||
SRC-90SA | Air cooling | 11.7 | 7 | 65 | 2980 | 380V50Hz | 268 | 2″ | 1530 | 1900*1240*1700 |
11.3 | 8 | |||||||||
9.5 | 10 | |||||||||
8.4 | 13 |
◆Type selection of working pressure (exhaust pressure)
When the user is ready to purchase an air
compressor, the first thing is to determine the working pressure
needed at the gas end, plus a margin of 1-2 bars, and then select
the pressure of the air compressor. (This margin is to consider the
pressure loss from the installation site of the air compressor to
the actual pipeline of the gas end, and to consider the pressure
margin between 1-2 bars according to the length of the distance).
Of course, the size of pipeline diameter and the number of turning
points are also factors affecting pressure loss, the larger the
pipeline diameter and the fewer turning points, the smaller the
pressure loss; conversely, the greater the pressure loss.
Therefore, when the distance between the air
compressor and the gas-end pipeline is too far, the diameter of the
main pipeline should be enlarged appropriately. If the
environmental conditions meet the installation requirements of the
air compressor and the working conditions permit, it can be
installed near the gas terminal.
Description:
♦ Fully seal & double screw, dual shockproof, smooth operation, can be installed anywhere.
♦ With a exquistie shape and compact structure and cover a small
area.
♦ Large displacement, stable pressure and high efficiency.
♦ Low exhause temperature (only 7 °C~10°C higher than the ambient temperature)
♦ Safe, liable, smooth operation, little noise and long maintenance cycle and using life.
♦ The intelligent control system completely satisfy the continuous cooperation without man work.
♦ Many screw air compressors operate together and start or shut
down automatically according to the air amount, and no man-work is
needed.
♦ It is more energy saving for a single compressor can adjust air demand automatically according to the users' air amount(frequency conversion type).