Product Details

10TPH Reverse Osmosis Filter System Waste Water Treatment Plant
 
Definition of RO water treatment system


The two-stage reverse osmosis pure water treatment system adopts two-stage reverse osmosis, and then after simple treatment, the water conductivity is less than 1μs/cm), which meets the national laboratory three-level water standard. The reverse osmosis system processes the fresh water into pure drinking mineral water. Our installations can make drinking water, mineral water, purified water and drinking water sources: ground, springs, wells, rivers, salt water, lake water, etc.
 
How do RO water treatment systems work?


"Osmosis" is a physical phenomenon. Reverse osmosis is to apply a greater pressure than natural osmosis in the water containing salt and various fine impurities (that is, raw water), so that the water will reverse osmosis from the side with the highest concentration to the side with the lowest concentration. , and the vast majority of bacterial impurities, organic matter, heavy metals, bacteria, and other harmful substances in the raw water are discharged through the sewage outlet.
 
Technical specifications of RO water treatment system
 

Model

JFRO-10T

Host Size

3000x1000x1700mm (can be customized)

Power

11KW

Power Supply

220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized

Operating Pressure

1.2~1.5MPa

Recovery Rate

70%

Designed Water Inlet

14t/h

Outlet Flow

10t/h

Desalination Rate

≥99.5%

RO Frame

SUS304

Membrane Size

8040

Membrane Elements

DOW /Hydranautics/Troy/ Vontron (Optional)

Number of Membranes

10

Raw Water Pump

CNP/NYP/GRUNDFOS (Optional)

High Pressure Pump

CNP/NYP/GRUNDFOS (Optional)

Tank Material

SS/FRP(Optional)

Control Valve

Manual/Automatic

Control Valve Brand

FLECK/RUNXIN

Membrane Housing

FRP

Number of Membrane housing

5

Pipe Material

U-PVC/ Stainless steel (Optional)

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
  
Process flow of RO water treatment system
 
Raw water → original water tank → original water pump → multi-media filter (quartz sand filter)→ activated carbon filter → soft water processor → precision filter → high pressure pump → first stage reverse osmosis (RO) device → pure water tank → high pressure pump → second stage reverse osmosis → ultraviolet sterilization device → water point

 
Unique characteristics of reverse osmosis water purification system equipment:


1. The single-membrane desalination rate can reach 99%, the desalination rate of the primary reverse osmosis system can generally be stabilized above 90%, and the desalination rate of the secondary reverse osmosis system can generally be stabilized above 98%.
2. Because the reverse osmosis equipment can effectively remove microorganisms, organic substances and inorganic substances such as iron and silicon, the quality of the effluent is higher than other methods.
3. The equipment has small footprint, compact structure, reliable operation and convenient operation.
4. The system is simple, the degree of automation is high, the fault is automatically shut down, and it has the function of automatic protection.
5. The recovery rate can reach more than 70%.
6. Save the chemical consumption cost, labor cost and waste water treatment cost generated by regeneration, and reduce environmental pollution.

 
Photos and details of Reverse Osmosis water treatment system



  
 

 

 

 

 

 

 

 

 

 

FAQ:
 
1, What are the inlet water quality requirements for ro water treatment system membrane components?
 

 

Items

NTUSDIResidual chlorine(mg/L)Fe2+(mg/L)TOC(mg/L)
Limits≤1≤5 ≤4≤3

 
 
 
 
 
 
2. What is the material of ro water treatment system membrane?
 
Acetate membrane (CA) : mainly because of its resistance to chlorine, so it is still durable. But its suitable pH range is small, easy hydrolysis
 Aromatic polyamide membrane (PA) : water almost can not have chlorine, only through a variety of pretreatment chlorine.
 
 
3. RO water treatment system configuration?
 
First-stage multi-stage process: if the recovery rate is not achieved in the first stage (50-65% in the first stage and 65-75% in the second stage), the multi-stage tandem filtration can be used. The effective cross-sectional area of each segment decreases. 2:2 and 2:3 and 4:2:1 
Multi-stage process: when the first stage process cannot meet the effluent quality requirements (the first stage is generally ≤20μs/cm), the product water of the first stage process is sent to another reverse osmosis unit. 
The arrangement of membrane components can be divided into series and parallel.
 
 
 

 

Hot Products

10TPH Reverse Osmosis Filter System Waste Water Treatment Plant Definition of RO water treatment ...
One Stage RO Water Treatment Equipment Water Desalination Plant What is Reverse Osmosis Water ...
50TPH RO Water Purification Plant Reverse Osmosis Water Treatment System Ro Water Treatment System ...
40TPH One Stage RO Water Treatment Plant Water Purifier Machine Reverse osmosis (RO) system is a ...
500LPH RO Water Treatment System FRP Reverse Osmosis Nitrate Removal Plant Product introduction of ...
Reverse Osmosis Water Treatment Plant Water Purification System What is RO Water Treatment System? ...