Home Companies Jufu Water Technology Co., Ltd

50TPH RO Water Purification Plant Reverse Osmosis Water Treatment System

Jufu Water Technology Co., Ltd
Active Member

Contact Us

[China] country

Address: 15F, Block B, FRD International Wealth Center, Fengcheng 12th Road, Weiyang District, Xi’an,Shaanxi, China 710018

Contact name:Chloe Cheung

Inquir Now

Jufu Water Technology Co., Ltd

50TPH RO Water Purification Plant Reverse Osmosis Water Treatment System

Country/Region china
City & Province Shaanxi
Categories Water Treatment
InquireNow

Product Details

 

50TPH RO Water Purification Plant Reverse Osmosis Water Treatment System
 
Ro Water Treatment System product introduction
 
High pressure pump, reverse osmosis membrane element, pressure vessel shell (membrane), cleaning system and control apparatus of the reverse osmosis system, reverse osmosis membrane pore size is small to nanoscale (1 nm = 10 to 9 meters), under the certain pressure, H2O molecules can pass RO membrane, and the source water of inorganic salt, heavy metal ions, organic matter, colloid, bacteria, viruses and other impurities through the RO membrane, Thus, pure water that can be permeated is strictly distinguished from concentrated water that cannot be permeated.
 
The Principle of Ro Water Treatment System


The raw water passes through the reverse osmosis membrane under the action of high pressure, and the solvent in the water diffuses from a high concentration to a low concentration to achieve the purpose of separation, purification and concentration. Because its permeation direction in nature is opposite, it is called reverse osmosis.
 
Technical Specifications of Reverse Osmosis Water Treatment System
 

Model

JFRO-50T

Host Size

7200x1500x1800mm (can be customized)

Power

45KW

Power Supply

220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized

Operating Pressure

1.2-1.5MPa

Recovery Rate

70%

Designed Water Inlet

70t/h

Outlet Flow

50t/h

Desalination Rate

≥99.5%

RO Frame

SUS304/Carbon Steel (Optional)

Membrane Size

8040

Membrane Elements

DOW /Hydranautics/Troy/ Vontron (Optional)

Number of Membranes

54

Raw Water Pump

CNP/NYP/GRUNDFOS (Optional)

High Pressure Pump

CNP/NYP/GRUNDFOS (Optional)

Tank Material

SS/FRP(Optional)

Control Valve

Manual/Automatic

Control Valve Brand

FLECK/RUNXIN

Membrane Housing

FRP

Number of Membrane housing

9

Pipe Material

U-PVC/ Stainless steel (Optional)

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  
 
Process flow of Reverse Osmosis Water Treatment System
 
Raw water pump - sand filter - carbon filter - cartridge filter - high pressure pump -RO membrane host machine -RO cleaning system
 

 
 
Application scope of Ro Water Treatment System


Residential and Villa Hotels/Hospitals Commercial Complexes Kinderney Dialysis Rooms Poultry Farms Food and Beverage Industry Bottled Water Plants Cooling Towers/Boiler Feed Water.
 
Features of Ro Water Treatment System


1. The reverse osmosis pure water equipment adopts a fully automatic control method to realize fully automatic operation and reduce the influence of human error operation on the equipment belt;
2. In the pretreatment system, the design of the reduction system is adopted to solve the irreparable impact of excessive residual chlorine on the reverse osmosis membrane;
3. Imported reverse osmosis membrane is used in the selection of reverse osmosis membrane, the service life can reach 3 years, and the conductivity of effluent is lower than 10US/CM;
4. The southern special SUS304 stainless steel water pump is selected for the pump series, and the running noise is low;
5. Using foreign professional design software, the recovery rate can reach more than 65%;
6. It has the characteristics of high degree of automation, simple operation, stable water quality and low operating cost. And widely used in production water in various industries
 
Photos and details of Reverse Osmosis water treatment equipment


 

 

 

 

 

 

 

 

 

 

 



FAQ:
 
 
1. What is the material of ro water treatment system membrane?
 
Acetate membrane (CA) : mainly because of its resistance to chlorine, so it is still durable. But its suitable pH range is small, easy hydrolysis
 
Aromatic polyamide membrane (PA) : water almost can not have chlorine, only through a variety of pretreatment chlorine.
 
 
2. RO water treatment system configuration?
 
First-stage multi-stage process: if the recovery rate is not achieved in the first stage (50-65% in the first stage and 65-75% in the second stage), the multi-stage tandem filtration can be used. The effective cross-sectional area of each segment decreases. 2:2 and 2:3 and 4:2:1
 
Multi-stage process: when the first stage process cannot meet the effluent quality requirements (the first stage is generally ≤20μs/cm), the product water of the first stage process is sent to another reverse osmosis unit.
 
The arrangement of membrane components can be divided into series and parallel.

 
 
3. What is the shell film material and specification of ro water treatment system?
 
Material of membrane case: stainless steel and fiberglass (FRP)
 
Specification of membrane shell: four inch membrane shell 4040 (one core to four core)
 
8 inch membrane case 8040 (one to seven cores)
 
Water inlet: end water inlet, side water inlet

Hot Products

10TPH Reverse Osmosis Filter System Waste Water Treatment Plant Definition of RO water treatment ...
One Stage RO Water Treatment Equipment Water Desalination Plant What is Reverse Osmosis Water ...
50TPH RO Water Purification Plant Reverse Osmosis Water Treatment System Ro Water Treatment System ...
40TPH One Stage RO Water Treatment Plant Water Purifier Machine Reverse osmosis (RO) system is a ...
500LPH RO Water Treatment System FRP Reverse Osmosis Nitrate Removal Plant Product introduction of ...
Reverse Osmosis Water Treatment Plant Water Purification System What is RO Water Treatment System? ...