MINI RCBO | Residual Current Operated Circuit Breaker with over-current protection

 

 

VRL11 MINI RCBO Residual Current Operated Circuit Breaker with over-current protection

(MCB sized 1 module with switched neutral)

 

1.1 Function

VRL11B mini RCBO type B and VRL11B+ mini RCBO type B+ are appearance design, compact structure, good reliability, and high safety. They are universal residual current circuit breaker with Overcurrent protection(RCBO).

Rated current up to 63A and for purposes of residual current protection, overcurrent (overload) and short circuit protection. When any personal electric shock occurs or the circuit leakage current exceeds the predetermined value, the RCBO can automatically cut off the power supply in a very short period of time, so that the safety of persons and electrical equipment can be operated.

Residual current circuit breaker with Overcurrent protection(RCBO) type B are suitable for domestic as well as industrial applications, where are used frequency inverters, PV plant, EV chargers and similar elements. B type provides a sensitivity to residual AC, pulsating and smooth DC current, together with high frequencies up to 1 kHz.

Residual current circuit breaker with Overcurrent protection(RCBO) type B+ meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA.

They are based on electronic technology, which brings advantages of more accurate measuring of residual current and, as a consequence, reduction of unwanted tripping. These devices also do not suffer with magnetization of the tripping unit.

 

1.2 Selection

Detectable wave form

Type B

Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents, alternating residual sinusoidal currents up to 1000Hz, pulsating direct residual currents and for smooth direct residual currents, whether applied suddenly or increasing slowly.

Type B+

Meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA

Tripping sensitivity

30mA - additional protection against direct contact.

100mA - co-ordinated with the earth system according to the formula IΔn<50/R, to provide

protection against indirect contacts;

300mA - protection against indirect contacts, as well as fire hazard.

Tripping time

Instantaneous It ensures instantaneous tripping(without time-delay).

Short time delay

Selective (time delay)

 

Tripping Curve B & C

 

2.2 Basic parameters

 

TypeBB+
Electrical
Design according toIEC/EN 62423, IEC/EN 61009-1, OVE E8601
  VDE 0664-400
Current test marks as printed onto the device
Rated voltage Un

2P: 230/240V AC

4P: 400/415V AC

Rated frequency fn50/60Hz
Mode of operation

"A type functionality: voltage independent

B and B+ type functionality: voltage dependent"

Operation voltage electronic50 – 264V AC
Voltage range test circuit

2P: 184 – 264V AC

4P: 184 – 440V AC

Rated current In6A,10A,13A,16A, 20A,25A, 32A, 40A, 63A

Rated residual

operating

current I△n

Instantaneous30mA, 100mA, 300mA, 500mA30mA, 100mA, 300mA
 K-short time delayed (G, ASi)30mA, 100mA, 300mA, 500mA30mA, 100mA, 300mA
 S- selective100mA, 300mA, 500mA100mA, 300mA
SensitivityAlternating, pulsed and smooth direct currents
 High frequency up to 1 kHZHigh frequency up to 20kHZ
Tripping CurveB: (3-5)In, C: (5-10)In
Rated insulation voltage Ui500 V
Rated impulse withstand voltage Uimp4 kV (1.2/50μs)
Rated conditional short-circuit current Inc6KA,10 kA
Rated making and breaking capacity Im3000 A
Peak withstand current

3 kA (8/20 μs) surge current proof

5 kA (8/20 μs) surge current proof for type S

Electrical isolation> 4 mm contact space

Endurance

(operating cycles)

electrical components≥ 2000
 mechanical components≥ 4000
Mechanical
Degree of protectionIP20
Upper and lower terminalsopen mounted / lift terminals
Terminal capacity1 - 25 mm2
Terminal torque2 - 2.5 Nm
Busbar thickness0.8 - 2 mm
Operating temperature-25°C ... +55°C
Storage- and transport temperature-40°C ... +70°C
Resistance to climatic conditionsIEC/EN 61009
Contact position indicatormechanical red / green
Supply possibilitytop or bottom
Mounting positionany

 

 

2.3 The residual current breaking times

 

In (A)I△n (A)Breaking time when the residual current assumes the following values (s)
I△n2I△n5I△n5A, 10A, 20A, 50A, 100A, 200A, 500A(a)I△t(b)
6~630.01, 0.03, 0.1, 0.3, 0.50.10.050.040.040.04

a. For tests of 5A, 10A, 20A, 50A, 100A, 200A and 500A, the current values beyond the lower limit of over-current instantaneous tripping are not tested.

B. Tests are done when I△t is equal to the lower limit current of over-current instantaneous tripping of type B and type C.

 

 

 

2.4 The over-current protection characteristics

 

No.Rated current In (A)Initial stateTest current (A)Specified time (t)Expected resultRemarks
a6 ~ 40Cold state1.13 Int ≥ 1hNon-tripping 
bImmediately after sequence a1.45 Int < 1hTrippingIncrease to the specified current within 5s after test item a.
cCold state2.55 In1s < t < 60sTripping 
dCold state3 Int ≥ 0.1sNon-trippingCurve B
5 Int < 0.1sTripping
5 Int ≥ 0.1sNon-trippingCurve C
10 Int < 0.1sTripping

 

3. Special features regarding the use of SIQUENCE universal current-sensitive residual current circuit breaker (Type B and Type B+)

3.1 Applications

      Typical applications that are vulnerable to smooth DC residual currents:

- Frequency converters with a three-phase connection

- Medical equipment such as X-ray equipment or CT machines

- Photovoltaic or UPS systems

- Connection points (wall boxes, charging stations) for electric vehicles

- Elevator controllers

- Pipeline trace heating

- Test setups in laboratories

- Construction sites in accordance with BGI 608 information leaflet (Electronic equipment on construction sites)

- Charging stations for battery-powered forklift trucks

- Cranes of all kinds

- Mixing plants if relevant loads are connected

- Variable-speed machine tools, such as milling and grinding machines or lathes

 

4. Wiring diagrams 

 

 

 

5. Tripping characteristics (B type)

 

 

3. Outline and installation dimensions (mm)

 

 

 

Product Description:

Residual Current Operated Circuit Breaker (RCBO) Type B is an innovative safety device designed for total protection of circuits from overloads, short-circuits, and leakage currents. It features top and bottom connection, 1P+N poles, and a frame size rated current Inm of 50A. It also offers a range of rated residual operating current from 0.01A, 0.03A, 0.1A, 0.3A, and rated current from 6A, 10A, 16A, 20A, 25A, 32A, 40A, and 50A.

The RCBO Type B Circuit Breaker offers a reliable and powerful protection system for residential and commercial applications. It is designed to detect any leakage current before it can cause damage, and it can be used in a variety of applications to protect both people and property. It is also easy to install and use, making it an ideal choice for those who want to ensure the safety of their electrical systems. This product is perfect for those who want to make sure their circuits are safe and secure.

 

Features:

  • Product Name: RCBO Type B
  • Rated Voltage: AC240V
  • Mechanical Life: 2000
  • Connection: From Top And Bottom, From Bottom And Top
  • Electrical Life: 2000
  • Product Type: Residual Current Operated Circuit Breaker (RCBO)

 

Applications:

HAROK's Residual Current Operated Circuit Breaker (RCBO) Type B is a reliable and efficient device for over-current and short-circuit protection. It is suitable for a wide range of applications, including residential, commercial, and industrial installations. It is designed to meet the latest standards IEC/EN 61009-1, AS/NZS 61009.1. This RCBO is available in various sizes and current ratings, from 50A to 4P. It is also classified by type of instantaneous tripping, with Type B (3 ~ 5) In, and Type C (5 ~ 10) In. It offers a maximum electrical life of 2000, and a maximum mechanical life of 2000. This product is manufactured in ISO 9001 certified plants, with strict quality control, ensuring superior quality and reliability.

HAROK's RCBO Type B is ideal for electrical wiring systems of all types, including residential, commercial, and industrial applications. It helps to protect cables and other connected devices from over-current and short-circuit. It also provides additional safety features, such as preventing fire and electric shock. With its reliable performance and long-lasting durability, this RCBO is perfect for a wide range of applications.

HAROK's RCBO Type B offers superior quality and reliability, and is a perfect choice for all types of electrical wiring systems. With its advanced features and high performance, it provides a reliable and efficient protection for your cables and devices. Whether it is for residential, commercial, or industrial applications, HAROK's RCBO Type B is the perfect choice for your electrical needs.

 

Technical Parameters:

Product NameRCBO Type B
Classified by Type of Instantaneous TrippingType B: (3 ~ 5) In, Type C: (5 ~ 10) In
Rated Residual Operating Current0.01A, 0.03A, 0.1A, 0.3A
Rated Residual Non-Operating Current0.005A, 0.015A, 0.05A, 0.15A
Poles1P+N
StandardIEC/EN 61009-1, AS/NZS 61009.1
Rated residual making and breaking capacity I△m500A
Rated Current6A 10A 16A 20A 25A 32A 40A 50A
Mechanical Life2000
Electrical Life2000

 

Customization:

HAROK RCBO Type B Residual Current Operated Circuit Breaker

Brand Name: HAROK
Model Number: VRL22 2P,4P VRL11 VAL003 VKL003 VDL006 VRL01 VRL02 VRL03 VK007LE 1P-4P
Place of Origin: CHINA
Mechanical Life: 2000
Product Name: RCBO Type B
Poles: 1P+N
Rated Voltage: AC240V
Rated impulse withstand voltage Uimp: 6000V

HAROK RCBO Type B Residual Current Operated Circuit Breaker is designed to protect your electrical system from overcurrent and short circuit faults. It is rated for AC240V, and is designed to withstand up to 6000V rated impulse voltage. It is available in 1P+N poles and has a Mechanical Life of 2000. This product is manufactured in China and carries the HAROK brand name.

 

Support and Services:

We provide technical support and service for our RCBO Type B product.

Our technical support team is available to respond to your inquiries any time of the day. We provide a 24/7 customer service hotline to help you with any product issues.

We also provide online tutorials and user manuals for our products. These materials are designed to help you set up and use our products with ease.

If you encounter any issues with our products, we offer full warranty coverage. We will repair or replace any defective products free of charge.

 

Packing and Shipping:

Packaging and Shipping for RCBO Type B:

  • The product should be packaged in a cardboard box.
  • The box should be labeled with appropriate shipping information and product description.
  • The product should be secured in the box in a manner that prevents damage during shipping.
  • The box should be sealed with sufficient tape to make sure that the product is not exposed to the elements during shipping.
  • The box should be shipped via a reliable shipping service to ensure safe arrival.

 

FAQ:

Q1: What is HAROK's RCBO Type B?

A1: HAROK's RCBO Type B is a device that integrates residual current protection and over-current protection, providing short-circuit protection and overload protection for electrical circuit. It is available in various models, including VRL22 2P,4P VRL11 VAL003 VKL003 VDL006 VRL01 VRL02 VRL03 VK007LE 1P-4P, all of which are made in China.

Q2: What are the advantages of HAROK's RCBO Type B?

A2: HAROK's RCBO Type B has a high level of protection and can identify leakage current quickly. It can provide effective protection against over-voltage, over-current, short-circuit and other faults. Additionally, it has a long service life and can be connected to a wide variety of circuit breakers.

Q3: What applications can HAROK's RCBO Type B be used for?

A3: HAROK's RCBO Type B can be used in many places, such as in buildings, factories, and residential areas. It can also be used to provide short-circuit and overload protection for electrical circuits.

Q4: What safety certifications does HAROK's RCBO Type B have?

A4: HAROK's RCBO Type B has obtained CE, RoHS, and other safety certifications.

Q5: What is the warranty period of HAROK's RCBO Type B?

A5: HAROK provides a one-year warranty period for all of its RCBO Type B products.

 

 

 

 

Hot Products

VAL003 Residual Current Operated Circuit Breaker with over-current protection(RCBO) (MCB sized 1 ...
RCBO | Residual Current Operated Circuit Breaker with over-current protection VKL003 Residual ...
mini RCBO | Residual Current Operated Circuit Breaker with over-current protection VRL03 Mini RCBO ...
MINI RCBO | Residual Current Operated Circuit Breaker with over-current protection VDL006 Residual ...
MINI RCBO | Residual Current Operated Circuit Breaker with over-current protection VRL11 MINI RCBO ...
RCBO | Residual Current Circuit Breaker with Overcurrent Protection VRL22B Residual Current Operated ...