Home Companies Yueqing Vorax Electric CO.,LTD

VDL006 Residual Current Operated Circuit Breaker With Over Current Protection Type B Witth 2000 Mechanical Life

Yueqing Vorax Electric CO.,LTD

Contact Us

[China] country

Trade Verify

Address: Liuhuang Road, Liushi Town, Yueqing City, Zhejiang Province

Contact name:Wellkins Lew

Inquir Now

Yueqing Vorax Electric CO.,LTD

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

VDL006 Residual Current Operated Circuit Breaker With Over Current Protection Type B Witth 2000 Mechanical Life

Country/Region china
City & Province zhejiang
Categories Battery Chargers
InquireNow

Product Details

MINI RCBO | Residual Current Operated Circuit Breaker with over-current protection

 

 

VDL006 Residual Current Operated Circuit Breaker with over-current protection (MINI RCBO)

(MCB sized 1 module with switched neutral)

 

1. General

 

VDL006 residual current operated circuit breakers are suitable for lines with AC 50/60Hz, rated voltage 240V, 120V, rated current up to 40A and for purposes of residual current protection, overload and short circuit protection. When any personal electric shock occurs or the circuit leakage current exceeds the predetermined value, the residual current operated circuit breaker can automatically cut off the power supply in a very short period of time, so that the safety of persons and electrical equipment can be operated. The residual current operated circuit breaker can be used for infrequent conversion of lines under normal conditions, and applied under occasions such as industrial, and commercial, high-rise buildings and residential houses.

 

2. Technical parameters

 

2.1 The tripping characteristic curves are as shown below. 

 

2.2 Basic parameters

 

 StandardIEC/EN 61009-1
Main SpecificationsModel No.VDL006
Rated current In

6A, 10A, 16A, 20A, 25A, 32A, 40A

Classified by Type of Instantaneous TrippingType B: (3 ~ 5) In, Type C: (5 ~ 10) In
Poles1P + N
Type (wave form of the earth leakage sensed)Type AC, Type A
Mechanical featuresRated voltage UeAC240V
Frame size rated current In40A
Rated residual operating current I△n10mA, 30mA, 100mA, 300mA
Rated residual non-operating current I△no5mA, 15mA, 50mA, 150mA
Rated short-circuit breaking capacity Icn

3000A, 4500A, 6000A

Rated residual making and

breaking capacity I△m

500A
Electrical life2,000
Mechanical life2,000
Rated impulse withstand voltage Uimp4000V
ConnectionFrom top and bottom, from bottom and top

 

 

2.3 The residual current breaking times

 

In (A)I△n (A)Breaking time when the residual current assumes the following values (s)
I△n2I△n5I△n5A, 10A, 20A, 50A, 100A, 200A, 500A(a)I△t(b)
6~400.01, 0.03, 0.1, 0.30.10.050.040.040.04

a. For tests of 5A, 10A, 20A, 50A, 100A, 200A and 500A, the current values beyond the lower limit of over-current instantaneous tripping are not tested.

B. Tests are done when I△t is equal to the lower limit current of over-current instantaneous tripping of type B and type C.

 

 

2.4 The over-current protection characteristics

 

No.Rated current In (A)Initial stateTest current (A)Specified time (t)Expected resultRemarks
a6 ~ 40Cold state1.13 Int ≥ 1hNon-tripping 
bImmediately after sequence a1.45 Int < 1hTrippingIncrease to the specified current within 5s after test item a.
cCold state2.55 In1s < t < 60sTripping 
dCold state3 Int ≥ 0.1sNon-trippingType B
5 Int < 0.1sTripping
5 Int ≥ 0.1sNon-trippingType C
10 Int < 0.1sTripping

 

 

 

3. Outline and installation dimensions (mm)

 

 

 

 

Product Description:

RCBO Type B is a residual current circuit breaker with over-current protection, used to protect people against electric shock caused by indirect contact with live parts. It is also used to protect wiring and equipment from overload and short-circuit. The rated residual non-operating current is 0.005A, 0.015A, 0.05A, 0.15A, with an electrical life of 2000. This product has a connection from top and bottom or from bottom and top, and is compliant with IEC/EN 61009-1 and AS/NZS 61009.1 standards. It is rated for AC240V voltage. This product is a reliable and safe solution for your residential or commercial electrical system.

 

Features:

  • Product Name: RCBO Type B
  • Rated Voltage: AC240V
  • Classified by Type of Instantaneous Tripping: Type B: (3 ~ 5) In, Type C: (5 ~ 10) In
  • Type: Type B
  • Frame size rated current Inm: 50A
  • Electrical Life: 2000

 

Applications:

HAROK's RCBO Type B circut breaker is a reliable solution for safety purpose. It is suitable for both residential and commercial use. This product is designed to provide protection against electric shock, fire and other hazards. It has a mechanical life of 2000 and is available in a variety of models such as VRL22 2P,4P VRL11 VAL003 VKL003 VDL006 VRL01 VRL02 VRL03 VK007LE 1P-4P. The connection of the breaker is from top and bottom or from bottom and top. It has a rated impulse withstand voltage of 6000V and a residual operating current of 0.01A, 0.03A, 0.1A, 0.3A. This RCBO circuit breaker is capable of accurately detecting leakage current and providing over-current protection. It is certified by international standards and is made from high-quality materials. It is a cost-effective solution and helps to ensure the safety of users.

 

Technical Parameters:

RCBO Type B
ParameterValue
Product NameRCBO Type B
ConnectionFrom Top And Bottom, From Bottom And Top
Rated residual making and breaking capacity I△m500A
Poles1P+N
Mechanical Life2000
Electrical Life2000
Rated Current6A 10A 16A 20A 25A 32A 40A 50A
Rated impulse withstand voltage Uimp6000V
Frame size rated current Inm50A
Rated VoltageAC240V

 

Customization:

HAROK RCBO Type B

Brand Name: HAROK
Model Number: VRL22 2P,4P VRL11 VAL003 VKL003 VDL006 VRL01 VRL02 VRL03 VK007LE 1P-4P
Place of Origin: CHINA
Poles: 1P+N
Rated impulse withstand voltage Uimp: 6000V
Rated Voltage: AC240V
Connection: From Top And Bottom, From Bottom And Top
Standard: IEC/EN 61009-1, AS/NZS 61009.1

The HAROK RCBO Type B is a residual current operated circuit breaker designed to provide protection against electric shock and fire hazards. This device is designed with 1P+N poles and rated impulse withstand voltage Uimp of 6000V. It is rated for AC240V and has connection from top and bottom, from bottom and top. It meets the standards of IEC/EN 61009-1, AS/NZS 61009.1.

 

Support and Services:

RCBO Type B Technical Support and Service

At ABC Inc., our RCBO Type B products come with comprehensive technical support and services to ensure your satisfaction. We provide professional support and services to help you get the most out of your product. Our technical support and services include:

  • 24/7 telephone and online technical support
  • Customized product solutions
  • On-site installation and maintenance
  • Online product tutorials and training
  • Regular product updates
  • Warranty and repair services

We are committed to providing the best technical support and services for our RCBO Type B products. If you have any questions or need assistance, please contact us and we will be happy to help.

 

Packing and Shipping:

Packaging and Shipping of RCBO Type B

RCBO Type B is shipped in a box that is designed to protect the product during shipping and handling. The box is made of corrugated cardboard and is sealed with tape. Inside the box, RCBO Type B is securely packaged in foam padding to prevent damage during transit.

The box is then placed into a larger shipping box, along with any other items that are being shipped. This shipping box is then sealed with tape and labeled with the appropriate shipping information. The package is then ready for shipping.

 

FAQ:

Q: What is the Brand Name of the RCBO Type B?
A: The Brand Name of the RCBO Type B is HAROK.
Q: What are the Model Numbers of the RCBO Type B?
A: The Model Numbers of the RCBO Type B are VRL22 2P,4P VRL11 VAL003 VKL003 VDL006 VRL01 VRL02 VRL03 VK007LE 1P-4P.
Q: Where is the RCBO Type B manufactured?
A: The RCBO Type B is manufactured in China.
Q: What type of circuit protection does the RCBO Type B provide?
A: The RCBO Type B provides overload, short-circuit, and earth leakage circuit protection.
Q: What types of loads is the RCBO Type B suitable for?
A: The RCBO Type B is suitable for residential, commercial, and industrial lighting and power loads.

 

 

 

Hot Products

TYPE B RCBO | Residual Current Operated Circuit Breaker with over-current protection VRL11 Residual ...
VAL003 Residual Current Operated Circuit Breaker with over-current protection(RCBO) (MCB sized 1 ...
RCBO | Residual Current Operated Circuit Breaker with over-current protection VKL003 Residual ...
mini RCBO | Residual Current Operated Circuit Breaker with over-current protection VRL03 Mini RCBO ...
MINI RCBO | Residual Current Operated Circuit Breaker with over-current protection VDL006 Residual ...
MINI RCBO | Residual Current Operated Circuit Breaker with over-current protection VRL11 MINI RCBO ...