Home Companies China World Technology Medical Equipment Service Group

Front And Rear Cover Case For Mindray Vital Signs Monitor VS900

China World Technology Medical Equipment Service Group

Contact Us

[China] country

Trade Verify

Address: TianHe District,GuangZhou,GuangDong

Contact name:Kiara

Inquir Now

China World Technology Medical Equipment Service Group

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Front And Rear Cover Case For Mindray Vital Signs Monitor VS900

Country/Region china
City & Province guangzhou guangdong
InquireNow

Product Details

Mindray Vital Signs monitor VS900 front and rear cover

Front And Rear Cover Case For Mindray Vital Signs Monitor VS900

 

Mindray Vital Signs monitor VS900 front and rear cover Brief introduction

 

Mindray Vital Signs Monitor VS900 is a compact and lightweight device that provides comprehensive measurement of a patient's vital signs.

The front cover of the VS900 is made of durable plastic and features a transparent screen that displays measurement results. It also has buttons and knobs to operate the monitor and adjust settings.

The back cover of the VS900 is also made of durable plastic and houses a variety of ports and connectors for connecting the monitor to other devices and accessories. It may have a battery compartment to power the device when it is not connected to a power source.

Both the front and back covers of the VS900 are designed to protect the monitor's internal components and provide a sleek, professional appearance. They are designed to be easy to clean and maintain, ensuring that the equipment remains in good condition over long periods of use.

 

 

 

Product Name

Mindray Vital Signs monitor VS900 front and rear cover

 

BrandMindray
ApplicationMindray Vital Signs monitor VS900
MaterialPlastic
MOQOne
Size178mm×150mm×260mm

 

 

Front View

(1) Alarm light

When a physiological or technical alarm occurs, this indicator flashes as described below.

■ High priority alarm: The indicator flashes red quickly.

■ Medium priority alarm: The indicator flashes yellow slowly.

■ Low priority alarm: The indicator is yellow and does not flash.

(2) Screen

(3) Temperature module and base

The monitor can be configured with one of the following modules.

■ SmarTempTM module: measures the expected temperature.

■ THP79JU module: measures ear temperature.

■ GeniusTM 2 module: Measures the temperature of the eardrum.

Temperature modules differ in appearance. The image above shows the main unit.

with the SmarTempTM module.

(4) AC indicator

■ On: indicates that the monitor is connected to power.

■ Off: Indicates that the monitor is not connected to power.

(5) power switch

■ Press this button to turn on the monitor.

■ When no parameters are measured, press this button to enter standby mode.

■ When the monitor is on, press and hold this button for more than 2 seconds to turn off the monitor.

The switch has a built-in display. It turns on when the monitor is on and turns off when the monitor is off.

(6) Battery indicator

■ Solid: Indicates the battery is installed and power is connected.

■ Off: Indicates that the battery is not installed.

■ Flashing: Indicates the monitor is running on battery power.

(7) Alarm reset button

■ Press this button to turn off the sound of the current alarm.

■ Press and hold this button for more than 2 seconds to pause or resume the alarm.

(8) Start/Stop button for non-invasive blood pressure

Press this button to start or stop NIBP measurement.

(9) Accept patient key

■ Press this button to admit new patients.

■ Press this button to return to the home screen.

(10) Button

■ Turn the knob clockwise or counterclockwise to move the cursor.

■ Press the button to select an item, for example to access a menu or confirm a selection.

 

 

Rear View

 

 

(1) Temperature probe

The appearance of the temperature modules is different. The image above shows a mainframe with a SmarTempTM module.

(2) Temperature probe connector

The appearance of the temperature modules is different. The image above shows a mainframe with a SmarTempTM module.

(3) Network connector: This is a standard RJ45 connector for communicating with external devices such as central monitoring systems, gateways or update systems.

(4) Multi-function connector: Connect to hospital nurse call system or connect to external devices via DIAP protocol.

(5) USB interface: Connect a barcode scanner or USB flash drive.

(6) AC power input

(7) Equipotential earth terminal

If the equipment is used with other devices, their equipotential ground terminals must be connected to eliminate the potential difference between them.

 

 

Thank you so much for your attention .If you're interested in Mindray Vital Signs Monitor VS900 Front And Rear Cover Case ,feel free to contact us .Thank you .

Hot Products

Philip Goldway GS20 Patient Monitor Bedside Monitor Philip GOLDWAY GS20 Patient Monitor Bedside ...
Edan iM20 Patient Monitor Edan iM20 Portable Transport Multi-Parameter Modular Patient Monitor ...
Philip Goldway GS10 Patient Monitor Bedside Monitor Philip GOLDWAY GS10 Patient Monitor Bedside ...
Mindray BeneView T6 Patient Bedside Monitor For Hospital Clinic Mindray BeneView T6 patient monitor ...
► PHILIP VM1 patient monitor REF 863264 Philip SureSigns VM1 is a cost-effective, easy-to-use and ...
Philip Goldway UT4000F Patient Monitor Main Board ML 94V-0 E211079 Philip Goldway UT4000F Patient ...