Home Companies TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO., LTD

1200W Outdoor Telecom Enclosure Double Door Weatherproof Electrical Cabinet

TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO., LTD

Contact Us

[China] country

Trade Verify

Address: 3A-8, No. 111, Taizi Road, Shuiwan Community, Zhaoshang Street, Nanshan District, Shenzhen, Guangdong, China

Contact name:Fiona Liang

Inquir Now

TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO., LTD

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

1200W Outdoor Telecom Enclosure Double Door Weatherproof Electrical Cabinet

Country/Region china
City & Province shenzhen guangdong
Categories Mobile Phone Chargers
InquireNow

Product Details

1200W Outdoor Telecom Enclosure Double Door Weatherproof Electrical Cabinet

 

1. Description Of IP55 Enclosure

 

IP55 Enclosure is suitable for the various environment including house electronic equipment, industrial process control, external plant, telecommunications equipment, food, and medical equipment, bespoke application and many more.IP55 enclosure provides complete protection against contact with live or moving parts inside the enclosure, thus add protection from water, up to water projected by a nozzle against enclosure from any direction.

 

2. Accessories Options Of The IP55 Enclosure

 

Fan kits

Cabinet insulation

Racks and shelving

Heating and cooling systems

Silk screening and digital printing

Custom locks, hinges and brackets

Lights, alarms and other electronics

 

3. Technical Parameters

 

ItemTypeTechnical Parameter
StructureDimensionExternal Dimension W×D×H 700×700×1550mm
LayoutOne compartment
Equipment Installation Method19” standard rack
DoorDouble Door, With one front door and one back door, totally two doors; with special lock for outdoor cabinet (support padlock)
MaterialGalvanized steel; double walls with heat insulation between two walls.
StructureAssembled
Ingress ProtectionIP55
Temperature ControlCooling1200W Air Conditioner and two fans
LightingLED lamp48V LED lamp
HumidityRelative Humidity5% ~ 100%
PressureAir Pressure62kpa ~ 101kpa (similar to 0m ~ 5000m altitude)

 

4. Accessories List

 

No.ItemQuantityUnitSpecs
1Outdoor Telecom Cabinet1Set

(1) External Dimension W×D×H 700×700×1550mm

(2) Double Door With one front door and one back door, totally two doors; with special lock for outdoor cabinet (support padlock)

(3) Material: galvanized steel; double walls, with heat insulation between two walls.

2Air Conditioner1Set1200W Air Conditioner, AC220V power supply
3110V To 220V Transformer1SetUsed for air conditioner input
4Fans2PCDC48V
5Power Distribution Unit1Set

Grade B Lightning Proof

Height: 3U

6Embedded Telecom Power System (UPS)1Set

DC48V, 90A, 4800W; Model:

GPE4890J

7Package1SetWooden Case
8Sensor  Sensors (including 1 smoke sensor, 2 door alarm, 2 LED lamp, 1 water sensor, and 1 temperature and humidity sensor.)

 

5. Enclosure Cooling

 

1 Set 1200W Air Conditioner, AC220V power supply

Two DC48V fans.

 

6. Cabinet Structure

 

(1) External Dimension W×D×H 700×700×1550mm;

(2) One compartment;

(3) Material: galvanized steel; double walls,with heat insulation between two walls.

 

7. Cabinet Picture:

 

 

8. GPE4890J Embedded Power System Operating Principle

 

GPE4890J consists of distribution unit, rectifier module (up to 3 sets) and 1 monitoring module After AC power is controlled by the AC hydraulic switch and then through the EMI board lightning protection and filtering processing, into the rectifier module, AC hydraulic switch has the function of overload and short circuit protection to AC power. Under normal conditions, every parameter of rectifier modules and distribution unit are all under control of the monitoring module, operating according to the pre-set parameter or user’s commands. If AC mains fault, the system will be powered by the battery. With the battery discharge, the terminal voltage of the battery starts to descend. When the battery voltage is under -46.2V±0.5V, the monitoring module reports battery under voltage alarm signal; When the battery voltage is under -45.6V±0.5V, close LVLD load output; When the battery voltage is under -43.2V±0.5V, close LVBD load output, then the power system stops working. When the external AC mains recovers, the system will resume to the normal work state. (All above monitoring data are system default values that users can reset).

Hot Products

Floor Mounted 19 Inch Rack IP55 Outdoor Telecom Cabinet With 500W Air Conditioner 1. Why need Floor ...
19 Inch 40U IP55 Outdoor Telecom Enclosure 1500W For Solar Energy Battery 1. Introduction Heavy ...
IP55 anti Corrosive Weatherproof Rack Enclosure Double Wall With Insulation 1. Introduction Estel ...
1.2mm Thickness Outdoor Telecom Enclosure 19 Inch 20U With Power System 1. Description Transmission ...
Two Walls Galvanized Steel Outdoor Electronics Cabinet Anti Theft Three Point Lock 1. Description Of ...
1200W Outdoor Telecom Enclosure Double Door Weatherproof Electrical Cabinet 1. Description Of IP55 ...