Home Companies TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO., LTD

1.2mm Thickness Outdoor Telecom Enclosure 19 Inch 20U With Power System

TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO., LTD

Contact Us

[China] country

Trade Verify

Address: 3A-8, No. 111, Taizi Road, Shuiwan Community, Zhaoshang Street, Nanshan District, Shenzhen, Guangdong, China

Contact name:Fiona Liang

Inquir Now

TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO., LTD

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

1.2mm Thickness Outdoor Telecom Enclosure 19 Inch 20U With Power System

Country/Region china
City & Province shenzhen guangdong
Categories Mobile Phone Chargers
InquireNow

Product Details

1.2mm Thickness Outdoor Telecom Enclosure 19 Inch 20U With Power System

 

1. Description

Transmission Cabinets-Transmission cabinets are equipped with numerous transmission racks. The purpose of transmission cabinets is to protect radio equipment on-site, assuring you can provide excellent service at all times.

 

2. Selling points and Features

- Cabinet design allows natural wind cooling through filtered vents on front door and venting under lip of rain hood

- All fixings are internal to the cabinet to provide a secure solution

-19" mounting rails front and rear

- Come with plinth for mounting on the floor ground, with cable grommets for the cabling

- Available in colors, Grey or customized colors

 

3. Technical Parameters

ItemTypeTechnical Parameter
StructureDimensionExternal Dimension W×D×H 750×750×1500mm
LayoutOne compartment
Equipment Installation Method19” standard rack
DoorDouble Door; with special lock for outdoor cabinet (support padlock)
MaterialGalvanized steel; double walls, thickness of outer plate: 1.2mm, thickness of inner plate: 0.8mm, with heat insulation between two walls.
StructureAssembled
Ingress ProtectionIP55
Temperature ControlCooling1200W Air Conditioner and 2 fans
LightingLED lamp48V LED lamp
TemperatureTemperatureWorking Temperature: -40°C ~ +55°C
Storage Temperature: -50°C ~ + 70°C
Transport Temperature: -50°C ~ +70°C

 

4. Accessories List

No.ItemQuantityUnitSpecs
1Outdoor Telecom Cabinet1Set

(1) External Dimension W×D×H 750×750×1500mm

(2) Double Door ; with special lock for outdoor cabinet (support padlock)

(3) Material: galvanized steel; double walls, thickness of outer plate: 1.2mm, thickness of inner plate: 0.8mm, with heat insulation between two walls.

2Air Conditioner1Set1200W Air Conditioner, AC220V power supply
3110V To 220V Transformer1SetUsed for air conditioner input
4Fans2PCDC48V
5Power Distribution Unit1Set

Grade B Lightning Proof

2 x 63A/1P

2x32A/1P

2x16A/1P

2x10A/1P

2x5A/1P

Height: 3U

6Embedded Telecom Power System (UPS)1Set

DC48V, 90A, 4800W; Model:

GPE4890J

7Package1SetWooden Case
8Sensor  Sensors (including 1 smoke sensor, 2 door alarm, 2 LED lamp, 1 water sensor, and 1 temperature and humidity sensor.)

 

5. Enclosure Cooling

1Set 1200W Air Conditioner, AC220V power supply

2 pcs DC48V fans.

 

6. Cabinet Structure

(1) External Dimension W×D×H 750×750×1500mm

(2) One compartment;

(3) totally two doors; with special lock for outdoor cabinet (support padlock)

(4) Material: galvanized steel; double walls, thickness of outer plate: 1.2mm, thickness of inner plate: 0.8mm, with heat insulation between two walls.

 

7. Cabinet Picture:

 

8. Power system connections

(1) AC input cable connections The connectors for AC input cable are two-core AC input sockets on the front panel of system. The AC cable can be directly inserted to the connector.

 

(2) Connection of DC load cables The terminals for load connection of the system are LOAD1-, LOAD2-, totally 2PIN, locating on the front panel of the system. The cable can be directly inserted into the terminal.

a. The specifications and model of the load cables shall be according to the engineering design requirements.

b. Connect one end of anode cable to “+” on the front panel of the system;

c. Connect one end of cathode cable to “LOAD1-” or “LOAD2-”the front panel of the system;

 

FAQ

Q1: Are you a manufacturer?
A: Yes, we are a experienced manufacturer with our own design and production lines.
Q2. Do you have any MOQ limit for outdoor cabinet ?
A: Low MOQ, 1pc for sample checking is available.
Q3: Can I get sample order?
A: Yes, we would like to get your sample order for testing our quality, the sample cost is paid by the customer.
Q4: Are you able to customize items with design or logo?
A: Yes, OEM & ODM is available.
Q5: How do you ship the goods and how long it will take?
A: We normally make shipment by sea or air which usually takes about 10- 50 days depend on the destination.
Q6: How long is the product warranty ?
A: We guarantee all our products 12 months warranty.

 

 

Hot Products

Floor Mounted 19 Inch Rack IP55 Outdoor Telecom Cabinet With 500W Air Conditioner 1. Why need Floor ...
UPS PDU 600W Outdoor Telecom Enclosure Anti Theft Lock With 1.5mm Thickness Plate 1. Description Of ...
1. Introduction 10 years of experience in the design and fabrication of electrical enclosures that ...
19 Inch 40U IP55 Outdoor Telecom Enclosure 1500W For Solar Energy Battery 1. Introduction Heavy ...
IP55 anti Corrosive Weatherproof Rack Enclosure Double Wall With Insulation 1. Introduction Estel ...
1.2mm Thickness Outdoor Telecom Enclosure 19 Inch 20U With Power System 1. Description Transmission ...