Huawei SDH OptiX Metro 100

 

Product Features

The OptiX Metro 100 supports various services interfaces, power input modes, and installation modes, and a high security mechanism.

Various E1 Service Interfaces

The OptiX Metro 100 supports three types of physical interfaces:

  • RJ-45 (120 ohms)
  • BNC (75 ohms)
  • DB15 (X.21)

High Network Security Mechanism

The OptiX Metro 100 supports the Radius security control, that is, the user names and passwords of all NEs are managed in a unified manner through the server of the user. Any user must pass the authentication before logging in to the NE. Therefore, the network security is high.

Support for Device Stack

The OptiX Metro 100 supports a maximum of 1+3 device stack (one master device and three slave devices), that is, 16xE1 services are configured into one optical channel.

Support for Default Settings

The OptiX Metro 100 is configured and maintained with the NMS and Web LCT, supporting the "one-click recovery to default settings" function.

Various Installation Modes

The OptiX Metro 100 can be installed in various ways. Therefore, you can select a proper installation mode according to the actual situation.

The OptiX Metro 100 supports the following installation modes:

  • Cabinet-mounting (19-inch cabinet, ETSI 600 mm cabinet, or ETSI 300 mm open cabinet)
  • Wall-mounting
  • Desk-mounting

Various Power Input Modes

The OptiX Metro 100 supports the following power input modes:

  • 110 V/220 V AC power input, the power input range is 90 V to 264 V, with the frequency in the range of 47 Hz to 63 Hz.
  • -48 V/-60 V DC power input, the power input range is -38.4 V to -72 V.

The OptiX Metro 100 supports one AC power input and one DC power input at the same time. The two power inputs back up for each other. The AC power input is controlled by a switch, whereas the DC power input is not. When the AC power input and the DC power input are unavailable at the same time, the OptiX Metro 100 reports the VOLT_LOS alarm indicating a power failure.

Low Power Consumption, Natural Heat Dissipation, and High Integration

  • Supports a maximum power consumption of 16 W only.
  • Supports natural heat dissipation and produces low noise.
  • Supports high integration.
Service Types

The OptiX Metro 100 supports SDH services,PDH services,Ethernet services.

Service TypeMaximum Access Capacity
SDH services2xSTM-1 (o)
PDH services4xE1
Ethernet services2xFE (e)
Function Unit
Functions and features of the PDH unit
Functions and FeaturesDescription
Basic functionTransmits and receives 4xE1 services.
Alarm and performance eventSupports various alarms and performance events, which facilitates the management and maintenance of the equipment; supports the alarm reversion function.
Clock source
  • Supports the settings and query of 4xE1 clock re-timing function.
  • Supports the extraction of E1 clocks over channel 1 only.
Maintenance features
  • Supports inloop and outloop at E1 ports so that faults can be located quickly.
  • Supports the setting of overhead bytes to be sent/received, thus enabling the board to function as an overhead instrument.
  • Supports the settings of thresholds for the excessive errors.
  • Supports pseudo-random binary sequence (PRBS).
Overhead processing
  • Processes path overheads at the VC-12 rate.
  • Supports the settings and query of overhead bytes such as J2 and V5.
Other functionsSupports three types of E1 interfaces: RJ-45 (120 ohms), BNC (75 ohms), and DB15 (X.21).

Functions and features of the SDH unit

Functions and FeaturesDescription
Basic functionTransmits and receives 2xSTM-1 optical signals.
Alarm and performance eventSupports various alarms and performance events, which facilitates the management and maintenance of the equipment; supports the alarm reversion function.
Clock source

Supports the line clock extraction function.

Maintenance features
  • Supports the outloop on SDH optical interfaces and inloop and outloop on VC-4 paths, and the automatic release of loopbacks.
  • Supports the setting of overhead bytes to be sent/received, thus enabling the board to function as an overhead instrument.
  • Supports the settings of thresholds for the excessive errors.
  • Supports PRBS.
Overhead processing
  • Provides transparent DCCs and orderwire byte channels.
  • Supports the setting and query of J0, J1, and C2 bytes.
Optical module
  • Supports the query of the manufacturing information about SFP modules.
  • Supports single-fiber bidirectional SFP optical modules.
  • Supports the status query of SFP modules.
  • Supports hot-swapping of SFP optical modules.
  • Supports the setting and query of lasers.
  • Supports the automatic laser shutdown (ALS) function of lasers.

Functions and features of the clock unit

Functions and FeaturesDescription
Clock protocolSupports the Standard Synchronization Status Message (SSM) protocol.
Working modeSupports the tracing mode, hold-over mode, and free-run mode.
Clock source

Supports the line clock extraction function.

  • When the tributary is normal, 2 MHz clock is extracted and transmitted to the cross-connect and timing module; when the tributary is abnormal, the cross-connect and timing module does not use 2 MHz clock.
  • Only the extraction of E1 clocks over channel 1 is supported.

Functions and features of the power unit

Functions and FeaturesDescription
Power supply typesSupports AC and DC power supplies.
Power supply protectionThe AC power input and the DC power input back up for each other. When the two power inputs are unavailable, the VOLT_LOS alarm is reported.
Power detecting unitSupports the detection on the AC power input and DC power input. When either of the power inputs fails, the POWER_FAIL alarm is reported.

Ethernet features supported by the OptiX Metro 100

FeatureDescription
Ethernet frame encapsulation formatSupports the GFP-F, LAPS, and HDLC encapsulation formats.
Jumbo frame
  • Supports the setting of the frame length to a value ranging from 1518 bytes to 9600 bytes.
  • Supports a jumbo frame with a maximum length of 9600 bytes.
Mapping modeSupports VC-12 or VC-3 virtual concatenation.
Ethernet test frameSupports Ethernet test frames.
Interface Characteristics
  • Supports auto-negotiation, 10/100M full-duplex working modes.

  • Supports traffic control at port, counting of transmitted and received packets, and query of port state.
Loopback
  • Supports Physical layer inloop or MAC layer inloops/outloops at the Ethernet port.
  • Supports inloops and outloops on VC-3 channels, and the automatic release of loopbacks.
LCASSupports link capacity adjustment scheme (LCAS).
LPTSupports point-to-point link pass through (LPT).
RMONSupports remote network monitoring (RMON).
Transfer or discard of frames shorter than 64 bytesSupports the discard (default setting) or transfer of frames shorter than 64 bytes. This function can be enabled or disabled on the NMS.
Frames with frame check sequence (FCS) errorsSupports the transparent transmission of frames with FCS errors. This function can be enabled or disabled on the NMS.
Minimum frame lengthSupports the setting of the minimum frame length to 64 bytes.

Functions and features of the extended unit

Functions and FeaturesDescription
Basic functionSupports the aggregation of a maximum of 16xE1 services into one optical path.
Maintenance functionSupports loopbacks on stacking interfaces.

Specification

SpecificationsMetro 100
AggregationSTM-1
Dimensions43.6 mm (H) x 442 mm (W) x 220 mm (D)
Switch Capacity1.25Gbit/s full higher order and lower order cross-connect capacity
Supported InterfacesSTM-1(o), E1(e), FE(e)
Power SupplyDC: -48V DC or -60V DC
AC: 220V/110V AC
Networking ModeSupports multiple SDH networking topologies, such as chain, ring, tangent rings, intersecting rings, etc
Clock SynchronizationLine clock source
Tributary clock source 
One external clock input/output (2 Mbit/s)
Auxiliary Interface

10M/100M NM interface, external UPM management port, stack interfaces Alarm interface

 

 

Delivery

Cargo will be delivered within 1 day after payment arrived. Tracking Number will be offered once delivery done.

Delivery OptionsEstimated Delivery Time
DHL3-5 business days
 Fedex3-5 business days
 By Sea10-20 business days

Notice:

 

Above mentioned information are just for your reference only,we will keep you posted for the tracking delivery schedule.There are two delivery options available for by air and by sea:

 

Deliver to port:

 

Uonel is responsible for transporting goods to port. All subsequent customs and transportation fees are the
responsibility of the buyer. Uonel will recommend trustworthy local freight forwarders to you.Uonel can facilitate the progress under buyer's permission and at buyer's expense.

 

Deliver to door:

 

Uonel will quote all destination charge prior once we have confirmed order.
Uonel is responsible for transporting goods to door after you have made the payment.

Warranty

   100% Low Price Guarantee:
              Uonel provides high-quality products at low wholesale prices


   100% Quality Assurance:
              All items are ORIGINAL NEW  and GENUINE only.
                    


   Free  Technical Support:

              Our FREE Huawei Expert Consultancy Support is over the phone, by chat, by email or by login remotely.


  100% Money Back Guarantee:
             You can contact our customer service team to exchange or return any product that you bought from us.


  Flexible Secure Payment & Shipment:
             Verified authorization: Mcafee Secure, VeriSign Secured

Return Material Authorization (RMA) Process

  

Standard Hardware Warranty Policy:

 

Original new sealed Huawei product: 1 Year

  

The Support Contacts:

  

If your Huawei products failed, you must contact your sales representative to verify product failure. If the problem still can't correct by remote support methods i.e. email or phone support, the RMA procedure will issue.

Company Profile

Uonel is one of the biggest Huawei Network Hardware distributor in china, founded in 2008. We are a global provider of netwotking  products with more than 5000 customers.

We provide original new Huawei Routers,Switches,Firewalls,Wireless APs & controllers,OLTs,GPON modems,optical transceivers.Our company have more than $5million Huawei products in stock.

Most of our technical engineers had work exprience in Huawei company,we can provide network design&planning,configration,troubleshooting,maintenance and training service in world wide.

 















Hot Products

Contact Us 02112954 SSQB9RACK02 N63E assembled cabinet (2000 x600x300mm) • OptiX OSN equipment uses ...
Contact Us 03030CRP SDH products OSN1500A SSR1AMU AMU 03030 CRP SSR1AMU alarm panels • OptiX OSN ...
Contact Us 03037557 SDH products OSN1500 SSR1EOW HUAWEI EOW 03037557 SSR1EOW public board • OptiX ...
Contact Us Huawei OptiX OSN 1500 Intelligent Optical Transmission System Product • OptiX OSN ...
Huawei SDH OptiX Metro 100 Product Features The OptiX Metro 100 supports various services interfaces...
SDH OptiX Metro 100 SS-SCBG01 The OptiX Metro 100 supports SDH services,PDH services,Ethernet ...