Wuhan Huaying Electric Power Tech & Science Co., Ltd |
|
Multi Function CT PT Test Set CT PT Analyzer High Accuracy 500 VA 15 Kg Weight
Equipment Description:
Technical parameters:
1. input voltage: AC220V ± 10%, 50Hz / 60Hz ± 10%
2. output voltage: 0.1 ~ 180V (AC)
3. output current: 0.001 ~ 5A (RMS)
4. output power: 500VA
5. the maximum equivalent inflection voltage: 45KV
6. the current measurement: Range: 0 ~ 10A (autoranging 0.1 / 0.4 /
2 / 10A)
7. the voltage measurement: Range: 0 ~ 200V (autoranging 1/10/70 /
200V)
8. turns ratio measurement: Range: 1 to 35,000,
9. phase measurement: Accuracy: ± 2min, Resolution: 0.01min
10. secondary winding resistance measurement range: Range: 0 ~ 8KΩ
(autoranging 2/20 / 80Ω / 800Ω / 8kΩ)
11. Working conditions: Temperature: -10 ℃ ~ 50 ℃, humidity: ≤90%
12. Size: 485mm × 356mm × 183mm
13. Weight: 15Kg
Technical Parameters:
1 Test standards: IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5,
C57.13 2 Power supply: AC220V±10%, 50/60Hz±10% 3 Voltage output: 0.1~180V (AC) 4 Current output: 0.001~5A(RMS) 5 Power output: 500VA 6 Maximum knee voltage measurement: 45KV 7 Current measurement: Range: 0~10A (automatically change range in 0.1/0.4/2/10A) Error: <±0.1%+0.01%FS 8 Voltage measurement: Range: 0~200V (automatically change range in 1V/10V/70V/200V) Error: < ±0.1%+0.01%FS 9 Turns ratio measurement: Range:1~35000 1~2000 error<0.05% 2000~5000 error<0.1% 5000~35000 error<0.2% 10 Phase measurement: error: ±2min; resolution: 0.01min 11 Winding resistance measurement: Range: 0~8kΩ (automatically change range in
2ohm/20ohm/80ohm/800ohm/8kohm) Error: < 0.2%RDG+0.02%FS Maximum resolution: 0.1mΩ 12 Temperature measurement:-50~100 Celsius degree; error<3
Celsius degree | 13 CT Secondary burden: Range: 0~160ohm (automatically change range in
2ohm/20ohm/80ohm/160ohm) Error: <0.2%RDG+0.02%FS Maximum resolution: 0.001ohm 14 PT Secondary burden: Range: 0~80kohm (automatically change range in 800ohm/8kohm/80kohm) Error :<0.2%RDG+0.02%FS Maximum resolution: 0.1ohm 15 PT ratio measurement: Range: 1~35000 1~10000 error<0.1% 10000~35000 error<0.2% 16 PT ratio error measurement: Typical error <0.05%, Maximum
Error<0.1% 17 PT phase angle measurement: maximum error < 3min 18 Make evaluation for test results according to selected standards 19 Make word report for test result 20 Make word reports one time for multi-group test records on the
PC 21 Calculate the ratio errors and phase angle errors at rated
burden and working burden in one time test 22 Compare excitation curves with saved excitation curves in the
same window 23 Memory capacity: >1000 groups test results 24 Working condition: temperature: -10℃~50℃; moist: ≤90% |