High Sensitivity Hall Effect Sensor Non Contact Current Sensor Ta=25℃±5℃

 

 

The TKC-BR series open loop mode current sensor is a open loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit .It provides accurate electronic measurement of DC, AC or pulsed currents.

 

 

Electrical data(Ta=25℃±5℃,RL=2KΩ,CL=10000PF)

 

Type

Parameter
TKC50BRTKC75BRTKC100BRTKC200BRTKC300BRTKC400BRTKC500BRTKC600BR

 

Unit


Rated input
±50±75±100±200±300±400±500±600A

Measure range
±150±225±300±600±900±900±900±900A

Rated output
@Ip=±Ipn ±4±1%V

Supply voltage
±15 ±5%V

 

Consumption

+18,-10mA

Offset voltage
±25mV

Magnetic offset
±30±25 @Ip=±IpnmV

Offset drift
≤±1.5≤±1.0mV/℃

output drift
≤±1.5≤±1.0mV/℃

Linearity
@Ip=0-±Ipn ≤1%FS

Response time
@50A/μS, 10%-90% ≤3μS

Galvanic isolation
@ 50HZ,AC,1min 2.5KV

 

Wire length

650~750mm

 

 

Applications

 

AC variable speed drives

Static converters for DC motor drives

Variable speed drives

Power supplies for welding applications

Battery supplied applications

Uninterruptible Power Supplies (UPS)

Switched Mode Power Supplies(SMPS)

 

 

Mechanical dimension(for reference only)

 

Remarks:

1. All dimensions are in mm.

2. General tolerance ±1mm.

 

 

Directions for use

 

When the current will be measured goes through a sensor, the voltage will be measured at the output end.

(Note: The false wiring may result in the damage of the sensor)

Customs can adjust Output amplitude of the sensor by needs.

Custom design in the different rated input current and the output voltage are available.

 

 

Standards

 

  • UL94-V0.
  • EN60947-1:2004
  • IEC60950-1:2001
  • EN50178:1998
  • SJ 20790-2000

 

General date

 

 ValueUnitSymbol
Operating temperature-40 to +85ºCTA
Storage temperature-40to +125ºCTS
Mass(approx)80gM

 

 

Characteristics chart

 

 

Pulse current signal response characteristic     Effects of impulse noise

 

 

Input current-Output Voltage characteristic

 

 

 

Hot Products

Blue AC DC Open Loop Hall Effect Current Sensor For Uninterruptible Power Supplies TKC-LB series ...
UL94-V0 Open Loop Hall Effect Current Sensor 100-2000A Input Current The TKC-N/NR series current ...
Measuring Hall Effect Based Current Sensor , Hall Effect Ac Current Sensor TKC-H TKC-H series is a ...
DC 500V 1000MΩ Open Loop Hall Effect Current Sensor Accuracy ±1% TKC-HAXseries current sensor is a ...
High Sensitivity Hall Effect Sensor Non Contact Current Sensor Ta=25℃±5℃ The TKC-BR series open loop ...
TKC-BS/BR Open Loop Hall Effect Current Sensor Pulsed Currents Measurement TKC-BS/BR series current ...