Blue AC DC Open Loop Hall Effect Current Sensor For Uninterruptible Power Supplies

Nanjing Token Electronics Science&Technology Co., Ltd.
Active Member

Contact Us

[China] country

Address: NO.80,FEITIAN AVENUE,INDUSTRIAL CLUSTER LUKOU TOWN

Contact name:Suki

Inquir Now

Nanjing Token Electronics Science&Technology Co., Ltd.

Blue AC DC Open Loop Hall Effect Current Sensor For Uninterruptible Power Supplies

Country/Region china
InquireNow

Product Details

 

Blue AC DC Open Loop Hall Effect Current Sensor For Uninterruptible Power Supplies

 

 

TKC-LB series current sensor is a open loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents.

 

Electrical data(Ta=25℃±5℃,RL=2KΩ,CL=10000PF)

 

Type

Parameter

TKC50LBTKC75LBTKC100LBTKC150LBTKC200LBTKC300LB

 

Unit

Rated input (Ipn)±50±75±100±150±200±300A

Measure range(Ip)
±150±150±200±300±400±450A
Rated output@Ip=Ipn ±4±1%V
Supply voltage±15 ±5%V

Power Consumption

+18,-10mA
Offset voltage±30±25mV

Magnetic offset voltage

≤±25≤±20mV
Offset voltage drift≤±1.5≤±1.0mV/℃
output drift≤±1.5≤±1.0mV/℃
Linearity@Ip=0-±Ipn ≤1%FS

Bandwidth

@ -3db DC…50KHz

di/dt

50A/uS
Response time@50A/μS, 10%-90% ≤3μS

Galvanic isolation
@ 50HZ,AC,1min 2.5KV

 

 

Applications

 

Variable speed drives

Welding machine

Battery supplied applications

Uninterruptible Power Supplies (UPS)

Electrochemical

 


Mechanical dimension(for reference only)

 

 

Remarks:

1. All dimensions are in mm.

2. General tolerance ±1mm

 

 

Directions for use

 

It will be in a forward direction when the Ip flows according to the direction of the arrowhead.

The primary conductor should be≤120℃.

The dynamic performance (di/dt and the response time) is the best when the primary hole is fully filled with the bus bar.

When the current will be measured goes through a sensor, the voltage will be measured at the output end.

(Note: The false wiring may result in the damage of the sensor)

Customs can adjust Output amplitude of the sensor by needs.

Custom design in the different rated input current and the output voltage are available.

 

 

Standards

 

  • UL94-V0.
  • EN60947-1:2004
  • IEC60950-1:2001
  • EN50178:1998
  • SJ 20790-2000

 

General date

 

 Value Unit Symbol
Operating temperature-40 to +85ºCTA
Storage temperature-40~+125ºCTS
Mass(approx)23gM

 

 

Characteristics chart

 

Pulse current signal response characteristic     Effects of impulse noise

 

Hot Products

TKC-EKA series dismountable open loop hall effect current sensor TKC-EKA series dismountable hall ...
100-2000A Hall Effect Current Sensor Transducer For Frequency Converter Characteristics chart The ...
Non Contact Hall Effect Dc Current Sensor / High Current Hall Effect Sensor The TKC-HAT series ...
Blue AC DC Open Loop Hall Effect Current Sensor For Uninterruptible Power Supplies TKC-LB series ...
UL94-V0 Open Loop Hall Effect Current Sensor 100-2000A Input Current The TKC-N/NR series current ...
Measuring Hall Effect Based Current Sensor , Hall Effect Ac Current Sensor TKC-H TKC-H series is a ...