Product Details

Micro load cell 1kg 2kg 5kg 10kg 20kg tension and compression force measurement
Forsentek miniature s-beam load cell FSSQ offers a compact design for a variety of applications. the S Beam Load Cell series provides accuracy, compact design features, and five capacity ranges 10N / 20N / 50N / 100N / 200N to choose from.The jr s-beam load cell FSSQ utilizes metal foil strain gauge technology to deliver 2.0mV/V output with maximum 0.2% non-linearity of the rated output,the compact design enables the FSSQ to be easily embedded into machinery or test equipment – ideal for packaging machinery, assembly machinery or end-of-line test equipment.The micro force sensor features M2 threaded holes on two sides for the mounting of attachments or implements for both tension and compression force measurement in applications with limited space.In addition to our standard product portfolio,Forsentek is also capable of and willing to customize load cell force sensor according to clients' specific requirements.

micro_tension_and_compression_load_cell_5kg_10kg_20kg

Dimensions(in milimeter)

micro_Force_load_cell_5kg_10kg_20kg

Ordering codeMeasurement RangeForce direction
FSSQ-10N0-10N / 0-1kgfTension/Compression
FSSQ-20N0-20N / 0-2kgf
FSSQ--50N0-50N / 0-5kgf
FSSQ-100N0-100N / 0-10kgf
FSSQ-200N0-200N / 0-20kgf

Specifications

Capacity

10N / 1kg / 2.2 lbf
20N / 2kg / 4.4 lbf
50N / 5kg / 11 lb
100N / 10kg / 22 lbf
200N / 20kg / 45 lbf

Rated output2.0mV/V
Excitation3-12V
Zero balance±0.1mV/V
Nonlinearity±0.2% R.O.
Hysteresis±0.2% R.O.
Nonrepeatability±0.1% R.O.
Creep(5min)±0.1% R.O.
Safe overload150% F.S.
Ultimate overload200% F.S.
Compensated temperature-10...+40oC
Operating temperature-20...+60oC
Temperature shift zero±0.03% R.O./oC
Temperature shift span±0.02% R.O./oC
Input resistance380±30 ohms
Output resistance352±3 ohms
Insulation resistance>2000M ohms
Ingress protectionIP62
Material of elementStainless steel
CableØ2*3000mm 4-core shielded
Wiring code

Compression@
Red--Excitation+   Black--Excitation-

Green--Signal+   White--Signal-

 

Load Cell:A device which produces an output signal proportional to the applied weight or force.

Wheatstone Bridge:A Wheatstone bridge is a network of four resistive legs. One or more of these legs can be active sensing elements. The Wheatstone bridge is the electrical equivalent of two parallel voltage divider circuits. R1 and R2 compose one voltage divider circuit, and R4 and R3 compose the second voltage divider circuit. The output of a Wheatstone bridge is measured between the middle nodes of the two voltage dividers.

Excitation: The voltage applied to the input terminals of the load cell.

Rated Capacity: The maximum axial load the load cell is designed to measure within its specifications.

Non-linearity: The maximum deviation of the calibration curve from a straight line drawn between the no-load and rated outputs; expressed as a percentage of the rated output and measured on increasing load only.

Non-repeatability: The maximum difference between load cell output readings for repeated loadings under identical loading and environmental conditions.

Hysteresis: The maximum difference between load cell output readings for the same applied load; one reading obtained by increasing the load from zero and the other by decreasing the load from rated output; usually measured at half rated output and expressed in percent of rated output.

Creep: The change in load cell output occurring with specified period of time, while under load, and with all environmental conditions and other variables remaining constant; usually measured with rated load applied.

Safe Overload: The maximum load in percent of rated capacity which can be applied without producing a permanent shift in performance characteristics beyond those specified.

Ultimate Overload: The maximum load in percent of rated capacity which can be applied without producing a structural failure.

Operating Temperature: The extremes of temperature within which a load cell will operate without permanent adverse change to any of its performance characteristics.

Temperature Shift Span: The change in output due to a change in load cell temperature; usually expressed as a percentage of load per degree Celsius change in temperature.

Temperature Shift Zero: The change in zero balance due to a change in ambient temperature; usually expressed in percent of rated output per degree Celsius change in temperature.

Input Resistance: The resistance of the load cell bridge circuit measured at the positive and negative excitation terminals with no load applied and with the output terminals open-circuited.

Output Resistance: The resistance of the transducer bridge circuit measured at the positive and negative signal terminals with no load applied and with the input terminals open-circuited.

Micro load cell 1kg 2kg 5kg 10kg 20kg tension and compression force measurement

micro_load_cell_5kg_10kg_20kg

Click here to download datasheet

Hot Products

Miniature flange force sensor 200N 100N 50N 20N 10N compression force measurement Flange Mounted ...
Micro load cell 1kg 2kg 5kg 10kg 20kg tension and compression force measurement Forsentek miniature ...
Subminiature force sensor 200N/100N/50N/20N/10N tension and compression force transducer Subminiatur...
Cylinder thrust measurement transducer 2kN 1kN 500N 200N 100N 50N 20N Thrust measurement transducer ...
Thrust force transducer 1kN/2kN/5kN/10kN/20kN actuator thrust measurement Thurst force transducer ...
Miniature tension and compression load cell 10N 20N 50N 100N 200N force transducer Miniature tension ...