Forsentek Co., Limited |
|
Miniature tension and compression load cell 10N 20N 50N 100N 200N
force transducer
Miniature tension and compression load cell FSSQ offers a compact design for a variety of applications. the S
Beam Load Cell series provides accuracy, compact design features,
and five capacity ranges 1kg / 2kg / 5kg / 10kg / 20kg to choose
from.The jr s-beam load cell FSSQ utilizes metal foil
strain gauge technology to deliver 2.0mV/V output with maximum 0.2%
non-linearity of the rated output,the compact design enables the
FSSQ to be easily embedded into machinery or test equipment – ideal
for packaging machinery, assembly machinery or end-of-line test
equipment.The micro force sensor features M2 threaded holes on
two sides for the mounting of attachments or implements for
both tension and compression force measurement in applications with
limited space.In addition to our standard product
portfolio,Forsentek is also capable of and willing to customize
load cell force sensor according to clients' specific requirements.
Dimensions(in milimeter)
Ordering code | Measurement Range | Force direction |
FSSQ-10N | 0-10N / 0-1kgf | Tension/Compression |
FSSQ-20N | 0-20N / 0-2kgf | |
FSSQ--50N | 0-50N / 0-5kgf | |
FSSQ-100N | 0-100N / 0-10kgf | |
FSSQ-200N | 0-200N / 0-20kgf |
Capacity | 10N / 1kg / 2.2 lbf 20N / 2kg / 4.4 lbf 50N / 5kg / 11 lb 100N / 10kg / 22 lbf 200N / 20kg / 45 lbf |
Rated output | 2.0mV/V |
Excitation | 3-12V |
Zero balance | ±0.1mV/V |
Nonlinearity | ±0.2% R.O. |
Hysteresis | ±0.2% R.O. |
Nonrepeatability | ±0.1% R.O. |
Creep(5min) | ±0.1% R.O. |
Safe overload | 150% F.S. |
Ultimate overload | 200% F.S. |
Compensated temperature | -10...+40oC |
Operating temperature | -20...+60oC |
Temperature shift zero | ±0.03% R.O./oC |
Temperature shift span | ±0.02% R.O./oC |
Input resistance | 380±30 ohms |
Output resistance | 352±3 ohms |
Insulation resistance | >2000M ohms |
Ingress protection | IP62 |
Material of element | Stainless steel |
Cable | Ø2*3000mm 4-core shielded |
Wiring code | Compression@ Green--Signal+ White--Signal- |
Load cell output: = (Power supply * Rated output) * Load / Capacity
Rated output is normally within 1mV/V~3mV/V.
Power supply is normally within 3-15V.
Load / Capacity is within 0-1.
So the load cell output signal is normally within
0-45mV(-45mV...+45mV for bidirectional load cell).
Example one: 2.0mV/V load cell with 10V power supply,the output
range is 0~20mV (-20mV...+20mV for bidirectional sensor).
Example two: 1.0mV/V load cell with 5V power supply,the output
range is 0~5mV (-5mV...+5mV for bidirectional sensor).
Load cell + Signal amplifier:
Load cell normally outputs -30mV...+30mV which sometimes cannot be
recognized by signal processing units directly,so signal
conditioner is introduced to convert mV signal into
0-5V/0-10V/4-20mA for easy signal processing.
Example: 10kg compression load cell working with 0-10V
amplifier,the load-output relationship will be 0-10kg load VS 0-10V
output,it is linear within the error range.
Load cell + Digital indicator
Digital indicator can work directly with load cell without signal
amplifier,here are some functions from the indicator:
-Display force value in real time
-Peak holding to grab the maximum force during testing
-RS485 or RS232 interface
-0-5V/0-10V/4-20mA analog output
-Switch output
Miniature tension and compression load cell 10N 20N 50N 100N 200N force transducer