Beijing Tengine Innovation Instruments Co.,Ltd |
Verified Suppliers
|
|
0 - 10NTU Digital Online Low Turbidity Analyzer / Meter With LCD
Displays MTU-S1C10
1. Application
• Drinking water monitoring: filter inflow and effluent, outlet of the water plant
• The water quality monitoring of water supply piping distribution system
• Industrial wastewater discharge monitoring
• Recycling and cooling water monitoring
• Boiler feedwater monitoring
2. Features and Benefits
• Built-in bubble removal system, Effectively eliminate the interference of air bubbles on the measured value
• Maintenance and cleaning easily, calibration and verification of the sensor in every 3 months.
• Digital sensor with good anti-interference performance and high stability, and the maximum extension of cable length is hundreds meters.
• “plug and play” sensor, and dual-channel transmitter.
• Modbus RS485/RS232 or Profibus DP network connection for data transmission is Optional. English menu.
• 3 Relays with programmable hysteresis provide high-limit alarm, low-limit alarm or timer.
• Built-in data logger with the capacity to store data for up to 10 years.
3. Specifications
Performance characteristics | |
Measuring Range | 0~10NTU,0~100NTU, 0~100mg/L |
Resolution | 0.01NTU, 1mg/L |
Accuracy | ±1%FS |
Repeatability | 1% |
Display | LCD displays data including date, time, measurement value, trendline, etc., English menu |
Data Storage | Automatic Data Storage for up to 10 years, power-off data protection |
Outputs | |
Analog Outputs | 0/4-20 mA output( maximum load 800 ohms), optional selection of 3.8mA or 21mA(under the condition of malfunction) |
Relay outputs | 3 Relays with programmable hysteresis, alarm or timer function optional |
Relay capacity | 2A, 250VAC |
Digital Communication | MODBUS RS232/RS485,Profibus DP is optional |
Power supply | |
AC power supply | 85~265 VAC, 50Hz/60Hz |
DC power supply | 24 VDC ±10% |
Physical parameters | |
Dimension of Transmitter | 270×205×100mm(W×H×D) (10.6*8*3.9 in.) |
Dimension of Sensor | 385×280×215mm(W×H×D) (15*11*8.5 in.) |
Materials | --Transmitter: PC --Sensor: PC |
Process connection of sensor | Circulation mounting, wall-mounting |
Environmental conditions | |
Ingress protection | --IP66 (transmitter) --IP66 (Sensor) |
Operating Temperature | --Transmitter: -20~60℃ --Sensor: 0~60℃ |
4. Ordering Information
Ordering Information | ||||||
Transmitter Selection | ||||||
| Channel number | Signal output | Power version | |||
MTU |
|
|
| |||
| code | meaning | code | meaning | code | meaning |
| 1 | Single channel | 0 | 4~20mA | AC | 220VAC |
| 2 | Dual channel | 1 | RS 485(Modbus) | DC | 24VDC |
|
|
| 2 | RS 232(Modbus) |
|
|
|
|
| 3 | Profibus DP |
|
|
Example: MTU10AC, single channel turbidity transmitter, output 4~20mA, 220V AC Power Supply. | ||||||
Sensor Selection | ||||||
| Measuting range | Cable length | ||||
MTU-S |
|
| ||||
| code | meaning | code | Meaning | ||
| 0 | 0~10NTU | C10 | 10m cable | ||
|
| 0~100NTU | CXX | XXm cable | ||
MTU-S0C10, a turbidity sensor, 0~10NTU , with 10m cable. |
(3) Accessories
FE0200: Sampling device