600~2000A KYN61-40.5 Power Distribution Switchgear / metal clad switchgear

 

Construction of 600~2000A KYN61-40.5 Power Distribution Switchgear / metal clad switchgear:

The design of KYN61 switchgear conforms to regulations for metal clad drawable switchgear in GB3906. It is mainly composed of two part, the cubicle body and the handcart. The cubicle divided into four sole compartment, the circuit compartment, bus bar compartment, cable compartment and gauge compartment. The degree of protection for the cubicle is IP4X, and IP2X for the compartments. The handcart includes the main switch (or other functional components) and support part.

 

Installation of 600~2000A KYN61-40.5 Power Distribution Switchgear / metal clad switchgear

To ensure the installation quality of the basic components, the frame levelness should be 1mm/1m.

For the switchgears in single line, the recommended width of aisle before the line is 2.5m, for the double lines of switchgear, the recommended width of aisle between the lines is 3m.

According to the requirements of the project and drawings, put the switchgear to the predetermined location, and arrange the rank from middle position.

The transportation should be carried out by using of specific equipments, such as crane or truck, but the using of rollers or levers is seriously forbidden, and the transportation of the enclosure with the handcart mounted in is seriously forbidden, the handcart should be put in until the accomplish of the installation of enclosure.

Take away the cable seal boards.

Following up the above steps, to install the switchgears one by one, the unevenness should no more than 2mm.

The switchgears can be coupled with or welded together firmly with the earth basic components.

 

Main technical specification of 600~2000A KYN61-40.5 Power Distribution Switchgear / metal clad switchgear

ParametersUnitSpecification
Rated VoltageKV40.5
Lighting impact withstand voltageKV185
Rated CurrentA630,1250,1600,2000
Rated short circuit currentKA25,31.5,40
Rated Short Circuit Closing CurrentKA63,80
Rated Dynamic Stable CurrentKA63,80
Protection Grade IP4X

Hot Products

XGTD5-(12,24)40.5 Indoor Gas Insulation Metal-Clad High Voltage Switchgear Service conditions a. ...
XGTD5-(12,24)40.5 Indoor Gas Insulation Metal-Clad High Voltage Switchgear General introduction ...
HXGT Series With 35~40.5KV SF6 CIS Gas Insulated High Voltage Switchgear General structure of HXGT ...
600~2000A KYN61-40.5 Power Distribution Switchgear / metal clad switchgear Construction of 600~2000A ...
ZFW-126/T2500-40 Gas SF6 Metal-clad Switchgear Product introduction of ZFW-126/T2500-40 Gas SF6 ...
DFT6-40.5 Series Cable Distribution Box General of DFT6-40.5 Series Cable Distribution Box The cable ...