Temperature Deviation ≤2.0 °c Salt Spray Test Box Composite Type Testing Machine

 

 

Compound salt spray test machine series

 

 

product description:

 

The cyclic corrosion test is a more realistic salt spray test than conventional constant state exposure. Because actual outdoor exposure usually involves both dry and wet environments, it is meaningful to speed up the laboratory to simulate these natural, periodic conditions. Studies have shown that after cyclic corrosion testing, the relative corrosion rate, structure, morphology and outdoor corrosion results of the samples are very similar. Therefore, the cyclic corrosion test is closer to real outdoor exposure than the traditional salt spray method. They can effectively evaluate many corrosion mechanisms such as general corrosion, galvanic corrosion and crevice corrosion.

 

The purpose of the cyclic corrosion test is to reproduce the type of corrosion in an outdoor corrosive environment. The test exposes the sample to a series of different conditions in a circulating environment. A simple exposure cycle, such as the Prohesion test, exposes the sample to a cycle consisting of salt spray and dry conditions. More complex automotive testing methods require a cycle of humidity and rest, in addition to salt spray and drying cycles. Initially these test cycles were performed manually, and the laboratory operator moved the sample from the salt spray chamber to the wet test chamber and then to a dry or stand-up unit. Microprocessor-controlled test chambers automate these test steps, reducing test uncertainty.

 

 

Test conditions:

 

According to GB, ISO, IEC, ASTM, JIS standards, the spray test conditions can be set and meet: GB/T 20854-2007, ISO14993-2001, GB/T5170.8-2008, GJB150.11A-2009, GB/ T2424.17-2008, GBT2423.18-2000, GB/T2423.3-2006, GB/T 3423-4-2008.

 

 

Features:

 

1. The wet temperature test curve can be completely recorded by LCD digital display color touch screen temperature and humidity controller (Japan OYO U-8256P).

 

2, control method: temperature, humidity, temperature and humidity can be used to control the program.

 

3, program group capacity: 140Pattern (group), 1400 Step (segment), each group of programs can be set up to Repest99 segment.

 

4. The execution mode time of each segment can be arbitrarily set to 0-999 hours and 59 minutes.

 

5, each group can arbitrarily set part of the cycle 1-999 times or all cycles 1~999 times;

 

6, with power-off memory function, resume power can continue to perform unfinished tests;

 

7, can be connected to the computer RS232 interface

 

 

Technical Parameters:

 

Specification modelJD-60SJD-90SJD-120SJD-1600SJD-200S

Inner box

size

(mm)

long600900120016002000
width45060090010001000
high400600700800800

Outer box

size

(mm)

long20502450283032303630
width15531553156015601560
high14301430183018301930
Laboratory temperatureBrine test method (NSS ACSS) 35 ° C ± 1 ° C / corrosion resistance test (CASS) 50 ° C ± 1 ° C
Pressure tank temperatureBrine test method (NSS ACSS) 47 ° C ± 1 ° C / corrosion resistance test method (CASS) 63 ° C ± 1 ° C
power supplyAC380V 40AAC380V 50AAC380V 60A
Saline concentrationAdd 0.26 g of copper chloride per liter in a sodium chloride solution concentration of 5% or a sodium chloride solution concentration of 5%
PH pH value6.5~7.2 3.0~3.2
Compressed air pressure1.00±0.01Kgf/cm³
Amount of spray1.0~2.0ml/80 cm3/h (at least 16 hours, average)
Laboratory temperature range0℃~60℃
Laboratory relative humidity1.35%-98%RH(±3%)
Spray methodProgrammable spray, damp heat, standing
Saturated barrel temperature47℃~70℃
Temperature fluctuation≤±1.0℃
Temperature uniformity≤±2.0℃
Temperature deviation≤2.0℃
Test time0~999 H, M adjustable
Defogging methodExhausting mist by air
Sample holderCustomized according to requirements
RemarksThe minimum laboratory space at the end of JD-60S meeting national standards must be 0.43m3 or more.

 

 

Introduction to the work process:

 

 

Spray process for cyclic corrosion testing:

 

The salt spray system consists of a solvent tank, a pneumatic system, a water tank, a spray tower, a nozzle, etc., and the brine is transported from the water storage tank to the test chamber by the Bernotte principle. The spray nozzle and the heat pipe work to provide the required humidity and temperature in the tank. The salt solution is atomized by compressed air by spraying.

The temperature inside the box is raised to the specified requirements through the bottom heating rod. After the temperature is stable, the spray switch is turned on. At this time, the salt spray test is performed. Compared with the ordinary salt spray test machine, the temperature in the test chamber is heated by the heating rod. While ensuring temperature uniformity, the effect of water vapor on the test results of the ordinary salt spray test machine is minimized.

The movable spray tower is designed for easy removal and maintenance, and the use of the test space is more flexible and convenient.

 

 

The salt spray test system has the following characteristics:

 

1. Control instrument: The controller adopts Korea imported "TEMI-880" 16-bit true color touch screen, the program group is 120 groups, and the total number of cycles is 1200 times.

 

2. Temperature sensor: anti-corrosion platinum resistance PT100Ω/MV

 

3, heating method: using titanium alloy high-speed heating electric heater, multi-point layout, stable uniformity

 

4, spray system: tower spray system, high-grade quartz nozzle, no work for a long time, no uniform distribution of fog particles

 

5, salt liquid collection: in line with the national standard funnel and standard metering cylinder, the settlement can be adjusted and controlled

 

6, two-pole intake decompression, to ensure the spray gas

 

 

The damp heat process of the cyclic corrosion test:

 

The humidity system consists of a water steam generator, a blast, a water circuit, a condensing device, etc. After the salt spray test, the machine will set up a defogging process to discharge the salt spray of the salt spray test to the test room as soon as possible; then the water evaporator will root The temperature and humidity set by the controller are suitable for temperature and humidity output. Generally, the humidity is relatively accurately calibrated and constant after the temperature is stabilized.

 

 

The instrument humidifier system has the following features:

 

Micro-motion humidification system using electronic parallel mode

 

The humidifying cylinder is made of whole PVC and is corrosion resistant.

 

Evaporator coil dew point humidity (ADP) laminar flow contact dehumidification

 

With double protection device for overheating and overflow

 

Water level control uses mechanical float ball valve to prevent electronic malfunction

 

The wet water adopts an automatic water supply system, which is suitable for continuous and stable operation of the machine for a long time.

 

 

Resting and drying process:

 

The static and drying system adds drying blowers, heating wires, air filters and other devices to the damp heat system. For example, it is required to simulate a standard atmospheric pressure environment test: temperature 23 ° C ± 2 ° C, humidity 45% ~ 55% RH, first The damp heat test of the previous paragraph is quickly removed by setting a defogging process to create a relatively clean test environment, and then the humidifier or dehumidification system is coordinated under the controller to produce an environment that meets the test requirements.

 

 

Test conditions:

 

Spray test conditions can be set:

 

A. Salt spray test: NSS * Laboratory: 35 °C ± 2 °C * Saturated air tank: 47 °C ± 2 °C

 

B, damp heat test:

 

1, test temperature range: 35 ° C - 60 ° C.

 

2, test humidity range: 80% RH ~ 98% RH can be adjusted.

 

C. Rest test:

 

1, test temperature range: 20 ° C - 40 ° C

 

2, test humidity range: 35% RH-60% RH ± 3%.

 

 

Use materials:

 

shell

1. Enclosure shell material: imported 8mm grade A PVC reinforced hard board, the surface is smooth and flat, and resistant to aging and corrosion;

 

2. Liner material: 8mm Class A corrosion-resistant PVC board.

 

3. Cover material: The cover is made of 8mm grade A corrosion-resistant PVC sheet, with two transparent observation windows. The cover and the box are made of special foam sealing ring to prevent salt spray from leaking out. The tip angle is 110° to 120°.

 

4, heating for multi-point air heating, heating up quickly, temperature distribution is even.

 

5, three-dimensional observable reagent supplement tank, you can observe the salt consumption at any time.

 

6. The well-designed water storage and water exchange system ensures smooth and reliable operation of the waterway.

The pressure barrel made of SUS304# stainless steel is electrolytically treated and has excellent corrosion resistance. The automatic water supply system eliminates the inconvenience of artificial water addition.

 

Freezing system

 

Compressor: original French Taikang fully enclosed refrigeration compressor

 

Condenser: wavy fin type forced air condenser

 

Evaporator: Titanium alloy evaporator is used in the laboratory to prevent corrosion

 

Electronic components: original solenoid valve, drying filter, expansion and other refrigeration components

 

 

Eight, standard installation equipment

 

nameQuantitynameQuantity
V type / O type rack1 setMetering cylinder1 branch
collector1 branchGlass nozzle1 branch
Spray tower1 setTest drug sodium chloride (500 g / bottle)2 bottles
Operating instructions1 servingPlastic anti-rust barrel (5L capacity)1
Automatic defogging function1 setAutomatic hydration function1 set

 

 

Core component schedule:

Serial numbernameOrigin brandRemarks
1ControllerKorea TEMI-880Connectable computer function
2Electromagnetic switchSchneider or equivalent brand productsCN11
3thermal relaySchneider or Omron220V5.5-8.5A
4Intermediate relayXindaMY2J
5TimerKorea SAMWONTECH (integrated with controller)AH3-3
6Over temperature protectionTaiwan ZhiheAT-350
7SSRKaiserSR-D2525
8Temperature sensorTaiwan Xuan RongPT100
9flashlightOsram220V18W
10Fuseless switchMitsubishi Japan220V40A
11Loop fanTaiwan Litie220V60W
12wind millTaiwan Shangyu6F
13compressorTaikang, FranceNAG2464Z
14CondenserTaiwan Zhongli 
15Condensing fanMar220V350M
16Dry screening procedureSAMWONTECHDML053S
17Expansion valveDanfoss, DenmarkNEL220
18The electromagnetic valveAirTACNEV220V
19High and low voltage switchJapan SAGINOMIYADNS-D306S
20Toggle heat exchanger (for cascade unit)DomesticCB14-20HSR16
21EvaporatorDomestic 
22The refrigerantDuPontR404A
23HeaterTaiwan Longxing220V1500W

 

 

After sales service:
Service center

Dongguan Jiedong Test Equipment Co., Ltd.

Tel: 0769-262657996 18938501819

Address: No. 117, Dongkeng Industrial Zone, Shipai Town, Dongguan City, Guangdong Province

Installation, commissioningJiedong engineers can be responsible for the installation, commissioning and start-up of the equipment after the company prepares the external conditions (such as water, electricity, etc.) required by the equipment, and provides good technical support and after-sales service, and equipment for the users. On-site training ensures that the trainees can independently and skillfully operate the equipment and complete simple maintenance work and routine maintenance of the equipment.
MaintenanceThe warranty period of the equipment is one year, and the official effective date is calculated from the date the buyer signs the acceptance certificate of the equipment. During the warranty period, Jiedong is responsible for the failure of the equipment for various reasons caused by its own reasons. Outside the warranty period, the repair work of the equipment is subject to the cost of spare parts and a certain service fee.
MaintenanceThe response time of the maintenance call is: respond within 3 hours; if you need to send technical service personnel to the site to resolve, we promise to send personnel within 24 hours; if for practical reasons, we must communicate with the customer to negotiate the latest date.
service itemsThe seller undertakes to provide technical support for the equipment for free during the use of the equipment.

 

 

Hot Products

Laboratory Capacity 720l Salt Spray Test Machine Precision Salt Spray Test Machine Precision salt ...
480l Salt Spray Test Chamber Humidity More Than 85% Jd-120 Salt Spray Test Machine JD-120 Salt Fog ...
Temperature Deviation ≤2.0 °c Salt Spray Test Box Composite Type Testing Machine Compound salt spray ...
Type 60 Salt Spray Test Chamber 108l For Salt Spray Corrosion Test Of Electronic Components And ...
Cross-cutting Speed 30-450mm/min Tensile Testing Machine Click Marking Test Equipment Click on the ...
Touch Screen Tensile Tester Speed Accuracy Indication Within ±1% Touch screen tensile testing ...