RS485 Rack Mounted UPS 10kVA TCHR33 Series 3 In 3 Out

TC Smart Systems Group

Contact Us

[China] country

Trade Verify

Address: No.618, Guangxing Rd, Songjiang District, Shanghai, P.R. China

Contact name:Stephen

Inquir Now

TC Smart Systems Group

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

RS485 Rack Mounted UPS 10kVA TCHR33 Series 3 In 3 Out

Country/Region china
City & Province shanghai guangxi
Categories Uninterrupted Power Supply (UPS)
InquireNow

Product Details

Product Application
 

TCHR33 series Rack mounted UPS is widely used in government, finance, communications, education, transportation, meteorology, radio and television, industrial and commercial taxation, health care, energy and electricity and other sectors.
 

 

Range of Power / Operating Methods
 

10-25kVA, 3 in 3 out/ 3 in single out, online double conversion
 

 

Product Features

 

TCHR Series online rack-mounted UPS is compatible with three-phase and single-phase AC output, with rated power of 10-25 kVA, input power factor of 1, 3 U height, and the system - including rectification, inverter, static bypass, charger, battery converter, control and status display light unit - all involved with discrete device. Its control board and sensitive terminals are designed in dust proof, for ease of use and reliability. It is ideal for modern data centers.
 

  • Smart Management
     

Its fault self-diagnosis and self-protection functions speed up and simplify maintenance. With auto-switching float chargers, it also provides RS232/SNMP monitoring ports. Its monitoring software logs power events, provides a variety of network schemes, and supports TCP/IP protocols, so as to achieve remote control and management.
 

  • Stability and Reliability
     

Based on DSP fully-digital control technology, the control circuit is simplified and obtains higher flexibility and reliability. Thanks to short circuit, overload, overheating, output over-voltage protection and current limiting technology, the system runs more stably. What's more, the power devices gain more space capacity for more reliable operation.
 

  • Green and Environmental Protection
     

Built-in EMC filter and dual surge protection makes it safer for load power, high input power factor reduces grid contamination, and ROHS compliance is required to meet the high standards of Class B electromagnetic compatibility.

 

  • High efficiency and Energy Reduction
     

It provides optimal quality of power distribution and ECO mode available for reduced energy consumption, with operating efficiency up to 95% or more. Its smart fan is adjustable in speed in order to reduce noise and save energy consumption. High power density makes it possible to cover less space and better improve operation efficiency.
 

  • Flexibility
     

Rack mounted, suitable for standard server racks, it can easily integrate with the servers. With user-friendly interface and 6.5-inch LCD touchscreen, it boasts abundant information, compatible with 3/3 and 3/1 systems.
 

  • Special design
     

Output power factor is 1, 15% higher than the common one. It supports a cold start with batteries to power on in order that an emergency power is available when needed. Its high input power factor is more than 0.99.

Very intuitive graphics and a variety of icon images are displayed distinctively, especially the battery monitoring interface. The battery capacity histograms show in different colors in response to the changes of the capacity percentage.

 

 

Technical Details

 

ModelTCHR3310CLTCHR3315CLTCHR3320CLTCHR3325CL
Capacity10kVA15kVA20kVA25kVA
Main InputTerminal Connectionthree phase + N + PE
Input Voltage380/400/415VAC (Line-Line)
Input Frequency50/60Hz
Power Factor>0.99
Current Distortion RateTHDi<4% (100% linear load)THDi<3% (100% linear load)
Range of Voltage304-478Vac (Line-Line) at full load;
304V-228Vac (Line-Line) linear derating from 100% to 75%
Frequency of Voltage40-70Hz
BatteryVoltage of Battery±240VDC (32-44 cells adjustable)
Charging Power20%* Active power (Max)
Charging Voltage Accuracy1%
BypassVoltage of Bypass380V/400V/415V (Line-Line)
Range of VoltageAdjustable, Default -20%-+15% Upper limit:+10%, +15%, +20%, +25%
Lower limit:-10%, -15%, -20%, -30%, -40%
Frequency Range of Bypass50/60Hz (rated power), adjustable:±1Hz, ±3Hz, ±5Hz
OutputRated Output Voltage380/400/415VAC (Line-line)
Rated Frequency50/60Hz
Output Power Factor1
Voltage Accuracy±1.0%
Output Dynamic Response<5% (20%-80%-20% load step 0%)
Dynamic Recovery Time<30ms (0%-100%-0% load step)
Output Total Harmonic Distortion<1% (linear load), <5.5% (nonlinear load)<1.5% (linear load), <6% (nonlinear load)
Inverter Overload110% transfer to bypass after 1 hour; 125% transfer to bypass after 10 minutes;
150% transfer to bypass after 1 minute; > 150% transfer to bypass after 200 ms
Frequency Accuracy0.10%
Range of TrackingAdjustable, ±0.5Hz-±5Hz, Default ±3Hz
Speed of TrackingAdjustable, 0.5Hz/S-±3Hz/S, Default 0.5Hz/S
Peak Ratio3:01
Three-Phase Accuracy120°±0.5°
SystemEfficiency of Main Mode>95%>95.5%
Battery Mode>94.5%>95%
ScreenLCD+LED+ color touchscreen
Protection RatingIP20
Communication InterfaceRS232, RS485, dray contacts, battery cold start
Working Environment0-40℃ (working temperature); -25℃~70℃ (storage temperature); 0-95% (no condensation )
Noise (dB) / m65dB@100% load, 62dB@45% load
OptionsSNMP cards, corporate cards, lightning protectionSNMP cards, corporate cards, lightning protection, LBS
Size (W*D*H) (mm)485*750*130 485*750*130 
Weight (kg)2530

Hot Products

Product Application TRM series modular UPS power, the industry leading, all-digital power distributi...
Product Application TCRM series modular UPS power, the industry leading, all-digital power ...
Product Application TCHR33 series Rack mounted UPS is widely used in government, finance, communicat...
Product Application TCHR11 series Rack Mounted UPS is widely used in government, finance, communicat...
Product Application TCMC Series Rack mounted Air Conditioner is mainly intended to cool the servers ...
Inrow Air Conditioner Application TCMC series Column-type Air Conditioner is intended to cool the ...