Symmetrical rail 35 mm PV Surge Protector, PV Heavy Duty SPDs

 

OBV5-C40-PV

 

PV Heavy Duty SPDs,Type 1+2 of surge protective devices comprises a complete range of compact protectors for common and differential mode protection against transient overvoltages at the DC-side of photovoltaic power plants or TNC.
Prewired modular complete unit for use in photovoltaic systems consisting of a base part and plug-in protection modules combined disconnection and short-circuiting device with safe electrical isolation in the protection module prevents fire damage resulting from d.c. switching arcs (patented SCI principle)
Tried and tested fault-resistant Y circuit of the OBV5-C40-PV prevents damage to the surge protective device in case of insulation faults in the generator circuitIntegrated d.c. fuse allows safe replacement of protection modules without arc formation.


Technical Parameters

 

Model: OBV5-C40-PV
Network voltage500Vdc600Vdc800Vdc900Vdc1000 Vdc 
Max. operating voltage Uc530Vdc630Vdc840Vdc950Vdc1060 Vdc 
Nominal discharge current ln20kA
Max. discharge current lmax40kA
Protection level (at In) Up1.8kV2.5kV2.8kV3.0kV3.2kV 
Disconnector
Thermal DisconnectorInternal
Mechanical characteristics
Connectionby screw terminals: 4-25 mm2
Disconnection indicator1 mechanical indicator by pole
Mountingsymmetrical rail 35 mm
Operating temperature-40/+85°C
Protection classIP20
Standards compliance
NF EN 61643-11 FranceParafoudre Basse Tension - Essais Classe II
IEC 61643-1 InternationalLow Voltage SPD - Test Class II
EN 61643-11 EuropeParafoudre Basse Tension - Essais Classe II

 

Feature&Benefits
 
1,Protect electric system and on-loading electrical apparatus from thunder and instantaneous over-voltage.
2,Protect transmission of Ethernet signals with 48V DC / 34V AC power supply circuits against
lightning induced surges.
3,Enhanced surge protection.
4,For mounting on 35mm DIN rails acc. to EN 60715.
5,It can effectively ensure the equipments work properly.
·Easy installation or retrofit.
·Din-rail mountable.
·Fail-safe /self-protected designRemote indicator (optional) with 3pin NO/NC contact.
·IP20 finger-safe designVisual indicator.
·Small foot print.
 
Application
●AC/DC distribution
●Power supplies
●Industrial automation
●Telecommunications
●Motor controls systems
●PLC applications
●Power transfer equipment
●HVAC applications
● AC drives
●UPS systems
●Security systems
●IT/Data centers
 
Others


Technology SPD parameter(Note:According to user requirement ,can be customized Uc=140V,440V,550V,voltage range of range of the SPD):

Type No.Rated Voltage(V) UnContinuous Voltage Uc(V~)Standard Discharge Current In(KA)

Max Discharge Current
Imax(KA)

Protection Level(KA~)Response Time(ns)
DGM1(2)-D5220/380

275/320
385/420

5101.2≤25
DGM1(2)-D101021.6
DGM1(2)-C2020401.8
DGM13-B303060.2.2
DGM3(4)-B4010802.4
DGM(4)-B60601002.8
DGM-N-PE220/25540/6060/801.2≤100

 
Transient voltage surgesin lv power lines
Transient overvoltages are voltage surges that can reach tens ofkilovolts with a duration of the order of microseconds.Despite theirshort duration, the high energy content can cause serious problemsto equipment connected to the line, from premature aging to destruction, causing disruptions to service and financial loss.Thistype of surge can have various different causes, including atmospheric lightning directly striking the external protection(lightning rods) on a building or transmission line or the associatedinduction of electromagnetic fields on metallic conductors.
Outdoor and longer lines are the most exposed to these fields,which often receive high levels of induction.
It is also common for non-weather phenomena, such as transformer centre switching or the disconnection of motors orother inductive loads to cause voltage spikes in adjacent lines.
 

Surges in telecom andsignalling networks
Surges tend to induce currents in allmetal conductors; not only are thepower lines affected, but so are allcables to a greater or lesser extent,depending on the distance to the focusof the surge.
Although a lower current is induced,the effect produced is equally or moredestructive, due to the greatersensitivity of electronic equipmentconnected to communications lines(telephone, Ethernet, R, etc.).

 
Importance of theground connection
Overvoltage protectors (SPD) divert excess energy toground, so limiting the peak voltage to an acceptablevalue for connected electrical equipment.
A ground connection in adequate condition is, therefore,a key aspect for effective protection against overvoltages.Monitoring ground connection condition guaranteesproper operation of surge protection devices.
 

Comprehensive protection
An effective overvoltage protection must combine thefollowing protection systems:
External protection (ESE lightning rods and faradization).System for protection against direct lightningstrike.These capture the lightning within the protectedarea and lead it, in a controlled manner, safely to ground. Internal protection (power frequency overvoltage andsurge protection devices). Equipment designed to protectagainst the effects of overvoltages in equipment connected to the power supply systems and/orcommunications networks.Grounding systems (grounding and insulation monitoring).Systems that allow atmospheric dischargecurrents to be dispersed into the ground. The need formonitoring the grounding system.CUAJE offers a widerange of products for each of these systems. It alsodevelops custom products, provides advice and consultingservices and the best possible aftersales service.
 
What skills should lightning protectors have in the selection?
 
1.Confirm power supply system
First of all, you must determine what your power distribution system is like, whether it is TT, TN or IT system. After determining the power distribution system, you can choose the protection mode and wiring method of the lightning arrester to select the appropriate lightning arrester.
For example, TN-C uses 3P lightning protection device, TN-S uses 4P, TT uses 3P+N, etc.
 
2.Know the main parameters of the lightning arrester.
 
FAQ

 
Q: Can I get some samples?
A: Yes, Sample orders welcomed.
 
Q: Can I use my own Logo or design on goods?
A: Yes, Customized logo and design on mass production are available.
 
Q:What is the delivery time?
A: 3 days for samples, 7-15 days for mass production.
 
Q: What is the payment term?
A: T/T, L/C at sight, West union , Paypal, etc.

Hot Products

Operating temperature (-40~+85°C) Pv Surge Protection / IP20 Prewired modular complete unit for use ...
900V 2 Poles PV Surge Protector , 40KA PV Surge Arrester For Solar Panel OBV5-C40-PV Prewired ...
40KA PV Surge Protector Connected By Screw Terminals: 4-25 Mm2 OBV5-C40-PV Prewired modular complete ...
Lightning Surge Protector 20-40KA 800V PV System, Solar Lightning Arrester OBV5-C40-PV Prewired ...
Symmetrical rail 35 mm PV Surge Protector, PV Heavy Duty SPDs OBV5-C40-PV PV Heavy Duty SPDs,Type 1...
Power Surge Protection Device , Type 2 Surge Protection EN 61643-11 OBV10-I-15 Surge protectors ...