Power Surge Protection Device , Type 2 Surge Protection EN 61643-11 


OBV10-I-15

 

Surge protectors OBV10-I-15 meet the type 1 requirement class according to IEC 61643-11. These devices protect low-voltage consumer systems from overvoltages of all types and are available in single-pole to four-pole versions.The voltage-limiting,high-performance spark gaps provide several benefits.A short response time, a low protection level and high current leakage capability with long service life.


Technical Parameters

 

Model: OBV10-I-15-Pluggable
Maximum continuous operating voltageUcV255/275/320/385
SPD to EN 61643-11  Type 1
SPD to IEC 61643-1  class I
LPZ  0→2
Lightning impulse current (10/350μs)IimpkA15
Lightning impulse current (10/350μs) [total] kA60
Nominal discharge surge current (8/20μs)InkA60
Maximum discharge surge current (8/20μs)ImaxkA100
Voltage protection levelUpkV2,5
Response timetAns<25
Follow current quenching capacity IpeakIfi peakkA12.5
Maximum back-up fuse A315
Temperature rangeϑ°C-40℃~+85℃
Protection rating  IP 20
Connection cross-section, rigid mm²10-50
Connection cross-section, multi-wire mm²10-35
Connection cross-section, flexible mm²10-25
 

Feature
 

• Meet the type 1 requirement class according to IEC 61643-11.
• Red: functionless, immediate replacement required.
• Equipped with a thermal disconnection device and provide real-time fault indicators thus allowing
complete operational safety.
• Easy to install in any standardized distribution pane or control cabinets.

 
Application


● These devices protect low-voltage consumer systems from overvoltage.
● Applied in modular SPD Class I + Class II (Class B + C) for TT and TN-S power supply system.

 

Others
Technology SPD parameter(Note:According to user requirement ,can be customized Uc=140V,440V,550V,voltage range of range of the SPD):

Type No.Rated Voltage(V) UnContinuous Voltage Uc(V~)Standard Discharge Current In(KA)

Max Discharge Current
Imax(KA)

Protection Level(KA~)Response Time(ns)
DGM1(2)-D5220/380

275/320
385/420

5101.2≤25
DGM1(2)-D101021.6
DGM1(2)-C2020401.8
DGM13-B303060.2.2
DGM3(4)-B4010802.4
DGM(4)-B60601002.8
DGM-N-PE220/25540/6060/801.2≤100

 
Transient voltage surgesin lv power lines
Transient overvoltages are voltage surges that can reach tens ofkilovolts with a duration of the order of microseconds.Despite theirshort duration, the high energy content can cause serious problemsto equipment connected to the line, from premature aging to destruction, causing disruptions to service and financial loss.Thistype of surge can have various different causes, including atmospheric lightning directly striking the external protection(lightning rods) on a building or transmission line or the associatedinduction of electromagnetic fields on metallic conductors.
Outdoor and longer lines are the most exposed to these fields,which often receive high levels of induction.
It is also common for non-weather phenomena, such as transformer centre switching or the disconnection of motors orother inductive loads to cause voltage spikes in adjacent lines.
 

Surges in telecom andsignalling networks
Surges tend to induce currents in allmetal conductors; not only are thepower lines affected, but so are allcables to a greater or lesser extent,depending on the distance to the focusof the surge.
Although a lower current is induced,the effect produced is equally or moredestructive, due to the greatersensitivity of electronic equipmentconnected to communications lines(telephone, Ethernet, R, etc.).
 
What skills should lightning protectors have in the selection?
 
1. Confirm power supply system
First of all, you must determine what your power distribution system is like, whether it is TT, TN or IT system. After determining the power distribution system, you can choose the protection mode and wiring method of the lightning arrester to select the appropriate lightning arrester.
For example, TN-C uses 3P lightning protection device, TN-S uses 4P, TT uses 3P+N, etc.
 
2. Know the main parameters of the lightning arrester.
 
FAQ

 
Q: Can I get some samples?
A: Yes, Sample orders welcomed.
 
Q: Can I use my own Logo or design on goods?
A: Yes, Customized logo and design on mass production are available.
 
Q: What is the delivery time?
A: 3 days for samples, 7-15 days for mass production.
 
Q: What is the payment term?
A: T/T, L/C at sight, West union , Paypal, etc.

Hot Products

900V 2 Poles PV Surge Protector , 40KA PV Surge Arrester For Solar Panel OBV5-C40-PV Prewired ...
40KA PV Surge Protector Connected By Screw Terminals: 4-25 Mm2 OBV5-C40-PV Prewired modular complete ...
Lightning Surge Protector 20-40KA 800V PV System, Solar Lightning Arrester OBV5-C40-PV Prewired ...
Symmetrical rail 35 mm PV Surge Protector, PV Heavy Duty SPDs OBV5-C40-PV PV Heavy Duty SPDs,Type 1...
Power Surge Protection Device , Type 2 Surge Protection EN 61643-11 OBV10-I-15 Surge protectors ...
AC 385V 60KA Power Surge Protection Device , Lightning Protection Of Class I OBV10-I-15 Surge ...