Home Companies Starlight Industry Co.,Ltd.

1200kW Soundproof Natural Gas Generator

Starlight Industry Co.,Ltd.
Active Member

Contact Us

[China] country

Address: Room 711, 7F, Unit 2, 1st Building, 666 Fengxi Avenue North Section, Wenjiang District, Chengdu

Contact name:Robin Liao

Inquir Now

Starlight Industry Co.,Ltd.

1200kW Soundproof Natural Gas Generator

Country/Region china
City & Province chengdu
Categories Gas Turbine Generators
InquireNow

Product Details

1200kW Soundproof Natural Gas Generator

 

Technical Specification of 1200kW Soundproof Natural Gas Generator

 

GensetTypeOpen Type ■ Canopy Type □
ModelEN1200NG-0.48kV
Country PlaceIndoor
Continuous Power/Frequency1000kW/60HzBackup Power/Frequency1200kW/60Hz
Electricity Efficiency %39.1%Electricity Efficiency (MJ/kW·h)9.2

Dimensions

(mm)

5700*1950*2240Weight kg9150
Operation ModeSingle Unit□ Combined ■ Connect to Grid□ Emergency□
Ambient

1. Indoor■ Outdoor(Normal□ Sand□)

2. Ambient Temperature:-15℃-45℃

3. Working Mode:Continuous■ Backup□

4. Humidity ≤90%

5. Fuel Type: Natural Gas

Methane Value MN≥80,Fuel Heat value ≥28MJ/Nm3

Note: If natural gas supply is different than above mentioned, kindly provide exact fuel composition to us.

Working Altitude≤1000m
Operation Noise≤118dB(A)
Grade of Performance (GB 2820)

G2□ G3□ G4■

1. 0-250kW sudden load test,genset frequency drop≤-10% and frequency resume to normal within 6.4S.

2. 400kW-0 sudden unload test, genset frequency increase ≤6.38% and frequency resume to normal within 8.3S.

3. At generator steady state (at continuous power with steady load, power factor≥0.8), rpm fluctuate range ≤±1.5%;

 

Above data acquired in laboratory with standard environment. Fuel shall be standard natural gas.

AlternatorBrand & ModelStanford HCI634K
Alternator Cover Standard NumberSAE0Disc Coupling Standard Number18
Rated Power1500KVABackup Power/
No. Of BearingsSingle Bearing■ Double Bearing□
Alternator ParameterEfficiency: 95.3% Power Factor: 0.8
Parallel Control CabinetBrand/ModelDEIF AGC222+IOM220
SwitchesABB
Main FunctionsAutomatic synchronization, load distribution, auto-protection, data communication and recording etc.

 

The engine rated power and rated fuel consumption rate is based on ISO3046-1 stipulated standard ambient conditions: ambient temperature 25℃, atmospheric pressure 100kPa and humidity 30%.

 

Power Definition and Operation Conditions for 1200kW Soundproof Natural Gas Generator

 

If natural gas is not as stipulated, there will be power loss for engine and life time of engine will be effected. Extra heat value won’t improve engine power. However, limited heat value will cause loss of engine power. If heat value is less than 28MJ/m³ and CH4 content is lower than 60%, the engines can’t work properly.

 

Hot Products

125KVA Soundproof Diesel Generator Starlight 125KVA soundproof diesel generator adopts top brand ...
1500KVA Natural Gas Generator Baudouin Engine Power Definition and Operation Conditions for 1500KVA ...
1500KVA Natural Gas Silent Power Generator Technical Specification of 1500KVA Natural Gas Silent ...
450kW Biogas Generator with Soundproof Canopy The 450kW biogas generator with soundproof canopy ...
1200kW Soundproof Natural Gas Generator Technical Specification of 1200kW Soundproof Natural Gas ...
Convert Diesel Truck to Diesel Natural Gas Truck - ECU ECU is the control unit of convert diesel ...