1200 kW Baudouin Natural Gas Engine (CHP) CNG CHP Gas Generator

 

1.1 Basic Requirements of Project

 

1.1.1  Output voltage: 400kV

          Frequency: 50Hz

          Power Factor: 0.9 and above.

 

1.1.2  Operation Mode: Isolated and synchronized. Generators are started by 24V power black startup, no outside power supply is required.

 

1.1.3. Other Requirements: The generators shall be in canopy with horizontal cooling system and electrical fans. Gas leakage warning devices are needed.

 

1.2 Gas Composition & Heat Value

 

Daily natural gas supply is 60000 cubic meters per day. However, gas pressure is not clear. The generator sets need natural gas pressure around 20-50kPa.G  Natural gas composition as following:

Table 1-1 Natural Gas Composition

 

Gas TypeMole PercentRemarks
CH484.94% 
C2H64.85% 
C3H81.81% 
C4H100.72% 
C5H12plus2.81% 
N24.38% 
Ar0.05% 
He0.03% 
H20.6% 
CO20.08% 
 

The natural gas heat value is around 40.6MJ/Nm³. Gas generator can, according to variant of gas composition, automatically adjust natural gas concentration and timing of ignition to ensure reliable and efficient operation of the generator itself.

 

2. Gas Generators

 

Weichai 16M33D1280NG gas engines and mecc alte ECO46 alternators are selected. In one canopy, one 1.2MW gas generator, one horizontal cooling system and one control system are integrated. The canopy is sand and catkin proof. The temperature zone control design enables the generator be normally operated at temperature range -30℃ to 50℃.

 

Total power plant capacity is 12MW and all generators are combined. Any of the generators can be backup set which enables urgent shift of any other generator. An isolate switch is installed for each of the generator which will isolate any gas generator when necessary.

Generator Model: EW-1200NGB-1/4A.

 

1.2MW Gas Generator Design

 

3.1 Canopy

 

The 30-feet long canopy is exclusively designed for the 1.2MW generator. The surface is coated by polyurethane which is shining and wear-resisting. In the canopy, there are control cabinet, generator cabin, air inlet/outlet filtering system. On the top of the canopy, there is horizontal cooling system. Gas supply is set at one end and power cable is connected from another end. This layout makes site gas pipe and cable arrangement easy and convenient.

 

3.2 Gas Engine

 

Baudouin 16M33D1289NG gas engine is selected. The gas engine is deeply developed in fuel control systems to improve its electric efficiency, reliability and fuel adaptivity for certain working conditions. The development also give consideration for dynamic responsiveness, fuel economy, reliability and safety.

 

Proven gas engine is controlled by imported gas close-loop lean-burn control system which includes latest Woodward control system, Hoerbiger intelligent ignition system, ABB high efficient turbocharger, single cylinder in-dependant compactive ignition, electrical speed regulating system, fuel close-loop control system, environment self-adaptation system and self diagnose and protection system. All these systems will ensure accurate and reliable control of gas engine and ensure its economic, dynamic and environmental performances. The systems are also optimized by our company to achieve high reliability and efficiency.

 

3.3 Cooling System

 

High-low temperature horizontal cooling system, high efficient, low power electrical fans, inter-cooler and jacket water cooling capacity close-cycle control are equipped to enable the generator being used in different ambient temperature.

 

Table 3-1:1.2MW Cooling System Parameters

 

 Jacket RadiatorInter-cooler Radiator
Designed Ambient Temperature50℃45℃
Designed Cooling Power960kW130kW
1200kW Cooling Redundancy115%122%
1100kWCooling Redundancy128%139%
1000kWCooling Redundancy143%155%
Radiator Area≥670㎡≥505㎡
MaterialsCopper Pipes/Copper FinsCopper Pipes/Copper Fins
Applied Ambient Temperature-30℃~50℃-30℃~45℃
 

3.4 Alternator

 

Mecc Alte ECO46 brushless synchronous alternating-current generator with strengthen moving components is selected to improve the alternators resistance to load impact and interference and to ensure its long term reliable and stable operation.

 

3.5 Generator Set Control System

 

Generator control system is DEIF intelligent generator control system which realizes automatic start, speed up, switching on, parallel, load allocation, brake separation, cooling and halt. Remote control and monitoring system is also available.

 

3.6 Gas Generator Technical Parameters

 

Table 3-2 Technical Parameters for 1.2MW/400V Gas Generator

S.NItemParameters
1Generator Set1.2MW Gas Generator with Canopy
1.1Generator ModelEW-1200NGB-1/4A
1.2Rated Power1200kW
1.3Rated Current2165A
1.4Rated Voltage230/400V
1.5Rated Frequency50Hz
1.6Startup ModeDC24V Electrical Start
1.7Speed RegulationElectrical Regulation
1.8Fuel ControlLean-burn, Close-loop Control
1.9IgnitionElectrical Control Single Cylinder In-dependant High Energy Ignition
1.10Generator Set ControlOne-Button Startup/Stop
1.11Lubricant Consumption≤0.2g/kWh
1.12Electric Efficiency≥40.1%(80%~100% Load)
1.13Dimensions9000×3000×2900mm(Height after Installation 4500mm)
1.14Net Weight14900kg
2Engine
2.1BrandWeichai/Baudouin
2.2Model16M33D1280NG
2.3Displacement52.3L
2.4Air IntakeTurbocharge, Forced Inter-cooler, Four-valve Structure
2.5Rated rpm1500r/min
2.6CoolingWater-air Inter-cooler, Forced Water Cooling
2.7LubricationForced Splash Lubrication
2.8Engine Thermal Efficiency42%
3Alternator
3.1BrandMecc alte
3.2ModelECO46 1S4A
3.3Power Factor0.8(Lag)
3.4Generating Efficiency95.3%
3.5Alternator Capacity1500kVA
3.6Phase3-phase 4-wire
3.7Insulation GradeH
3.8Protection GradeIP23
4Generator Set Control System
4.1BrandDeif
4.2ModelAGC200
4.3FunctionsOne-button startup/stop, data display, Recording, Protection and Monitoring etc.
4.4DisplayerRpm/lubricant pressure/water temperature/ running hours/ current/ voltage/ Frequency/ active power/ reactive power/ load distribution etc
4.5Protection FunctionsAlarming and automatic control for high water temperature, low lubricant pressure, over speed, overcurrent, AC/DC voltage low/high, short circuit etc
5CanopyDust-proof canopy with positive pressure ventilation

1. The data is based on heat value on or above 35.88MJ/Nm3 natural gas which conform to ISO8528/1, ISO3046/1 and BS5514/1 standards.

2. Technical data acquired under standard conditions: barometric pressure: 100kPa,Ambient temperature: 25°C, relative humidity: 30%.

3. Under standard conditions the data conforms to DIN standard ISO 3046/1evaluation.Rated natural gas consumption tolerance is within ±5%.

4. Power factor is 0.8 and above.

5. Fume Nox contends ≤500ppm;

 

  • Gas Generator Functions
  • Startup Model

The gas generators are started by 24V DC battery. No other diesel generator or grid power supply needed.

  • Emergent Stop

There are manual emergent stop and automatic failure emergency stop in the cases of natural gas leakage, overcurrent etc.

  • Gas Generator Control

One-button control, air-fuel ratio auto adjustment, power factor auto control, automatic load increase and decrease can be realized on the generator.

Generator Control System: The control cabinet has one displayer. In the cabinet, there are controllers, relays, fuses, meters, adjusting buttons, indicators and emergent stop button to monitor and control the generator’s working process.

  • Generator Protection in case of Failure

The control system has protection functions and sound/light alarmings for over load, over current, short circuit, reverse power, underfrequency, overfrequency, undervoltage, overvoltage, over speed etc.

For slight failures like high temperature of cooling water, low pressure of lubricant, over load, fail startup, there will be light and sound alarming and auto or manual stop is allowed.

For severe failure like high temperature of engine, low lubricant pressure, over speed etc, it will stop automatically and alarming will be sent out.

  • Conditions for Generator Operation
    • Natural Gas Requirement
      • At rated power natural gas pressure at inlet flange shall be within 20kPa≥P≥50kPa.
      • At rated power natural gas inlet pipe ID shall be DN80 or above.
      • At normal operation gas heat value is 40.6MJ/Nm³, considering all other circumstances, natural gas supply rate shall be 2500Nm³/h or above (calculated at 10MW load).

 

Table 5-1: Required Compositions for Natural Gas

Gas TypeItemRequirement
Natural GasHeat Value MJ/Nm³≥34
CH4 Content by Volume %≥82
Overall Sulphur mg/Nm³≤200
H2S Content mg/Nm³≤15
Impurity Particle Size μm<5
Content of Impurity g/m³≤0.03
 

Note: There will be effect to the engine if natural gas is not as required.

  • Coolant

Each engine shall be filled with 560L of coolant. Coolant shall be rust, scale and freezing resistant and shall contain glycol. Exact requirement as following table.

Table 5-2 Coolant Requirement

Ambient TemperatureCoolant Percentage
Glycol Volume PercentageWater Volume Percentage
≥5°0100
-10°C~5°C3367
-26°C~-10°C5050
-35°C~-26°C5644
 

5.3 Lubricant

Each engine shall be filled with 190 liters of lubricant for the first time and each replace volume shall be 170 liters. Gas (CNG/LNG) engine exclusive lubricant shall be added.

Lubricant Model vs Ambient Temperature as following table

 

Table 5-3:Lubricant Code and Corresponding Temperature

Lubricant CodeAmbient Temperature Range
15W/40-20℃~40℃
10W/40-25℃~40℃
5W/40-30℃~40℃
0W/40-35℃~40℃
 

 

 

5.4 Ambient Temperature & Humidity

The generator sets are for ambient temperature -30℃~50℃; If ambient temperature is above 40℃, rated power of generator will decrease. Ambient temperature increase each 5℃, rated power of generator set will decrease 5%.

Maximum allowed humidity is 95%. When humidity is above 30%, it will have effect on generator.

5.5 Altitude

Generator set allowed altitude is no more than 3000m; if altitude is above 1000m, rated power will decrease by 3% for each 500 m altitude increase.

 

  • Quality Guarantee

Guarantee period will be 12 months from EXW date or 3000 hours of operation, whichever comes first. Manufacturer will provide gas generator user manual and train buyer’s engineers. Any damages caused by misoperation or improper operation shall be responsibility of buyer.

Hot Products

#detail_decorate_root .magic-0{border-bottom-style:solid;border-bottom-color:#53647a;font-family...
500 kW Natural Gas Coalbed Methane Gas Generator & CHP (Cogeneration, Tri-generation) Gas Engine The ...
320 kW Biogas Natural Gas Engine Electricity Generator Natural Gas Generator The 320kW natural gas ...
120KW Baudouin Engine Combined Heat & Power (CHP) and Natural Gas Generator Descriptiion Gas ...
1200 kW Baudouin Natural Gas Engine (CHP) CNG CHP Gas Generator 1.1 Basic Requirements of Project 1...
1200KW Baudouin Natural Gas Electric Generator CHP Cogeneration Power Generator Description Gas ...