Product Details

 

Goyen dust collector valve CA35T CA35T010-300 1-1/2 " diaphragm pulse jet valve 

 

Description
High performance diaphragm valve with threaded ports. Available with integral pilot or as remotely piloted valve. Outlet at 90° to inlet.

Suitable for
Dust collector applications, in particular for reverse pulse jet filter cleaning including bag filters, cartridge filters, envelope filters, ceramic filters, and sintered metal fibre filters.

 

 

Construction 

Body: Aluminium (diecast) 

Ferrule: 304 SS 

Armature: 430FR SS 

Seals: Nitrile or Viton (reinforced) 

Spring: 304 SS 

Screws: 302 SS 

Diaphragm Seat: PA-6 (standard), Viton coated mild steel or High Density PE 

Refer to Q Series Solenoid product data sheet for solenoid construction details. 

 

 

Installation 
1 . Prepare supply and blowtube pipes to suit valve specification. Avoid installing valves underneath the tank. 
2 . Ensure tank and pipes are free from dirt, rust or other particulate. 
3 . Ensure supply air is clean and dry. 
4.  Mount valves to inlet pipes and blowtube to valves, ensuring no excess thread sealant can enter the valve itself. 
5 . Make electrical connections to solenoid or connect RCA pilot port to pilot valve ( RCA valves only ). 
6 . Apply moderate pressure to system and check for installation leaks. 
7 . Fully pressurise system. 
8 . Test fire and listen for proper actuation and crisp pulse noise. 

 

 

OPTIONS:
Recommended on time range: 50-500ms 
Recommended time between pulses: 1 minute or greater 

Maintenance 
Before conducting any maintenance activity on the system ensure that components are fully isolated from pressure and power supplies. Pressure and power should not be reapplied until the valve has been fully assembled. 
Diaphragm and pilot inspection should be conducted annually. 

 

1Valves can also be supplied with FPM (fluorelastomer) diaphragms and seal materials. Use the appropriate optional suffix 'V' for identification
2Sequential controller for pilot solenoid valves
3 Pilot boxes containing 2 to 12 pilot solenoid valves
4 Pilot solenoid valves can be equipped with explosionproof solenoids for hazardous locations according to “ATEX” and national standards

 


DIMENSIONS (mm) :

 

 

Product show:

 

Fitted Repair kits code: Diaphragm K3500 / K3501(Vition)

Hot Products

Goyen Aluminum pilot valve 3.2 mm 110 V AC 1/8 " RCA3D pulse jet valve Suitable for AII Goyen dust ...
Goyen dust collector valve CA35T CA35T010-300 1-1/2 " diaphragm pulse jet valve Description High ...
Goyen flanged inlet dust collector valve CAC45FS CAC45FS010-300 1-1/2 " diaphragm pulse jet valve ...
Goyen diaphragm valve CA20T 010-300 3/4 " AC230V dust collect right angle pulse jet valve Descriptio...
Goyen Aluminum diaphragm valve CA25T 010-305 1 " DC24V pulse jet valve Description High performance ...
Goyen Die cast Aluminum diaphragm valve CA45T 010-300 1 1/2 " AC230V pulse jet valve Constuction ...