Force sensor torque transducer |
|
High accuracy Load cell sensor 3kg 6kg 10kg 20kg 30kg 40kg Weighing Transducer
Dimensions
Specifications
Rated capacity | 3kg 6kg 10kg 15kg 20kg 30kg 40kg |
Rated output | 2.0±10%mV/V |
Excitation | 3-15V |
Zero balance | ±0.1mV/V |
Non-linearity | ±0.02% R.O. |
Hysteresis | ±0.02% R.O. |
Non-repeatability | ±0.015% R.O. |
Creep(30min) | ±0.03% R.O. |
Safe overload | 150% F.S. |
Ultimate overload | 200% F.S. |
Compensated temperature | -10...+40oC |
Operating temperature | -20...+60oC |
Temperature shift zero | ±0.05% R.O./10oC |
Temperature shift span | ±0.03% R.O./10oC |
Input resistance | 1130±20 ohms |
Output resistance | 1000±3 ohms |
Insulation resistance | >2000M ohms |
Ingress protection | IP65 |
Material of element | Aluminum alloy |
Cable | Ø4*400mm(Longer cable available) |
Wiring code | Red--Exc+ Black--Exc- |
Load cell sensor weight measurement transducer
A load cell sensor is a transducer that converts mechanical force
into electrical signal which is proportional to the weight(or
force) being applied.The measured load or force causes deformation
of the measuring element(elastic body),the bonded strain gauge
deforms accordingly which will cause the resistance change of the
wheatstone bridge,under constant power supply,the output signal
between Sig+ and Sig- will change proportionally,thus the
load/force can be measured by measuring the output signal from the
load cell.
The output range of a strain gauge load cell is normally between
0-30mV(-30~30mV for bidirectional sensor),and signal amplification
is necessary for most applications,a load cell signal
conditioner can be used to get ±5V,±10V,0-5V,0-10V or 4-20mA signal for easy data process afterwards
Digital indicator can be used to display the measured value,load
cell display FPT is CE certified with 24 bit high accuracy
ADC,sampling speed up to 960Hz,supports RS485 or RS232
communication port,can also output 0-5V,0-10V,0-20mV or 4-20mA
amplified signal.