500LPH Ro Filtration System One Stage Reverse Osmosis Water Purification Plant

 

Low pressure membrane:

 

Due to the advantages of saving energy consumption and reducing the pressure level of related mechanical parts, which leads to the decrease of material cost, the application proportion of ultra-low pressure membrane has been increasing since 1996, which is most prominent in the use of small devices mainly using 4 inch membrane. Take the largest domestic reverse osmosis membrane supplier, American Hedeneng Company, for example, 80% of the 4-inch film sold in the past two years is ultra-low pressure film. The application of ultra-low pressure film in large devices has also shown a significant upward trend. At present, the largest device using ultra-low pressure film in China has a water yield of 650 tons/hour.

 
Technical Specifications of RO Water Treatment System

500LPH Reverse Osmosis System
ModelJFRO-500L
Host Size800x600x1600mm (can be customized)
Power1.5KW
Power Supply220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized
Operating Pressure0.8-1.2MPa
Recovery Rate50%
Designed Water Inlet1000L/h
Outlet Flow500L/h
Desalination Rate≥99.5%
RO FrameSUS304
Membrane Size4040
Membrane ElementsDOW /Hydranautics/Troy/ Vontron (Optional)
Number of Membranes2
Raw Water PumpCNP/NYP/GRUNDFOS (Optional)
Raw Water PumpCNP/NYP/GRUNDFOS (Optional)
Tank MaterialSS/FRP (Optional)
Control ValveManual/Automatic
Control Valve BrandFLECK/RUNXIN
Membrane HousingSS/FRP (Optional)
Pipe MaterialU-PVC, Stainless steel (Optional)

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Low pollution of membrane:

 

Membrane fouling is the greatest harm in reverse osmosis application, which not only shortens membrane service life and increases operation cost, but also directly affects the efficient and continuous operation of membrane system. At present, several low-pollution films with strong anti-pollution performance, long service life, low cleaning frequency and easy cleaning have come out. Heidergy LFC1 film has the characteristics of electroneutral surface and good hydrophilicity. It has become the leader of the low-pollution family and the only low-pollution film used in large-scale reverse osmosis devices in China. At present, it has been successfully run in several large power plants, automobile factories, electronic materials factories and tea concentration plants in China. In addition, DOW's anti-fouling film uses mirror technology, which also has good anti-fouling performance.

 

A positively charged reverse osmosis membrane

 

Now widely used low pressure, ultra-low pressure composite film material are aromatic polyamide, the membrane surface are negative charge, there are membrane manufacturers have developed a surface with positive charge low pressure composite film, this film is mainly used in the preparation of high resistivity high pure water system, in Japan, The positive charge film ES10C produced by Nitto Denko has achieved high pure water resistivity of 10 ~ 15 megohm in the three-stage reverse osmosis system in the semiconductor industry, and the final water resistivity of the three-stage reverse osmosis system produced by Hyundai Electronics in Korea is 8 ~ 9 megohm. A 170 t/h three-stage reverse osmosis system in a semiconductor factory in Shanghai also reached the above targets. In addition, the resistivity of water produced by reverse osmosis is 1 ~ 4 megohm in the two-stage reverse osmosis system of the scale of 5 ~ 20 tons/hour in some domestic pharmaceutical factories. In 2000, the domestic pharmaceutical industry will put into production 20 sets of such reverse osmosis systems.

 

Process flow of RO Water Treatment System


Raw water → Raw water tank → Raw water pump → Multi-media filter (quartz sand filter) → Activated carbon filter → Soft water processor → Precision filter → High pressure pump → Primary reverse osmosis (RO) device → Purified water tank → High pressure pump → Two Stage reverse osmosis → ultraviolet sterilization device → water point.
 

 

Photos of reverse osmosis water treatment system


 

 

 

 

 

 

 

 

 

 

 

 

 

 


 
FAQ:
 
1. What is the design water yield of ro membrane element? (except anti-pollution membrane and seawater desalination membrane)
 
Model 4040 is designed by 0.25m3/h
 
Model 8040 is designed by 1-1.2m3/h
 
2. What is the material of mechanical filter?
 
Carbon steel, stainless steel, fiberglass
 
3.What are the multi-way control valves?
 
Manual control valve, automatic control valve
 
Multi - way control valve is divided into: filter valve and softening valve
 
Automatic control valve is divided into: time type and flow type.
 
Multi-way control valve brands are: FLECK, AUTOTROL, Runxin, clean source, etc.

Hot Products

2000L Per Hour Reverse Osmosis System Sea Water Ro Treatment Plant Reverse osmosis system referred ...
250LPH Ro Water Treatment Equipment Reverse Osmosis Filter System Reverse osmosis usually uses ...
6TPH Water Purification Ro Water Treatment Plant Reverse Osmosis System Reverse osmosis referred to ...
1000L/H Double Stage Ro Water Purification Machine For Food Production Use Reverse osmosis membrane ...
500LPH Ro Filtration System One Stage Reverse Osmosis Water Purification Plant Low pressure membrane...
Water Desalination Machine 18TPH Reverse Osmosis System Filtration Plant The reverse osmosis system ...