Hebei Kaixiang Electrical Technology Co., Ltd |
|
Electrical Load Bank 2500KW , Resistive Load Bank For Storage
Battery Systems
Product Description
According to the special requirements of users on site, in the
agreement the technical standards of AC11-2500kw Intelligent
Load Bank (hereinafter referred to as "system") and its accessories
are proposed including their function, performance, usage,
structure, installation and test to provide users with a high
efficient and reliable choice, in order to meet the need for
generator load test.
Technical Parameter
Rating Voltage/Frequency | 400VAC/50Hz,3 phase 3 wire |
Rated Load Power | Resistive load: 2500kW |
Installed Capacity | Resistive load: 2500kW |
PF(Power Factor) | 1 |
Load Tolerance (each step) | ±5% |
Load Tolerance(overall) | ±3% |
Display Precision | 0.5 class |
Control Power | 380VAC/50Hz, 3 phase 4 wire, |
Wire Connection | Load power supply input——Copper bar (star coupling) |
Insulation | F |
Protection Grade | IP54 |
Way of Working | Continuous Working |
Casing Dimensions and Cooling | about 6058*2350*2591mm (length*width*height) Forced air cooling,Horizontal inlet air,Vertical cooling |
Weight | About 6500kgs/set |
Transportation | Hoisting, there are lifting lug in top of casing |
Casing Color | Grey(RAL7035) |
Ambient Temperature | -10℃~+50℃ |
Relative Humidity | ≤95% |
Altitude | ≤1500 meter |
Atmospheric Pressure | 86~106kPa |
Contactor | Schneider |
Fuse | DELIXI |
MCU | INFINEON |
Data processing software | Kaixiang(self-developed) |
Alloy Resistance | Kaixiang(self-developed) |
Product Advantage
System can load power in rated range, measure generator
steady-state 3 phase voltage, current, active power, power factor,
frequency, and running time, and simulate the generator set, UPS
real load working state. Power input using sectional type, energy
dissipation type load, forced-air cooling, 3 phase fan
decentralized supply air, air-flow is sufficient and low noise.
Application
Motor manufacturing: The load bank is an ideal test equipment for
generator power ,the frequency,the voltage,the current,power factor
and other generator parameters.Most of the generator use the diesel
oil,which can cause the fuel oil unfilled,carbon deposition
,complete machine efficiency reduced when the diesel oil load is
lower than 50% or in idling situation for a long time and even
cause starting difficulty ,power insuffciency,oil consumption
increased,finally,opening the cylinder for maintenance too early
and the abandonment ,so the load bank will be generator's ideal
false load.