400V 1000KVA Dummy Load Bank In Good Performance And Resistive Inductive

Introduction

AC400V-1000KVA Dummy Load Bank  can accurately test output power and load capacity with all kinds of generators

generator sets for all main electrical parameters including the dynamic parameters tested.

System monitoring and load the cabinets of two parts, with the host computer with the use of intelligent, auto-complete for all the electrical parameters of the generator set special test,

while generating charts, graphs and test reports, from full manual operation. Provides a scientific means of detection equipment for the power generators.

Application

AC400V-1000KVA Dummy Load Bank can be used in a wide variety of applications , such as

Factory testing of turbines ,Factory testing of engine generator sets,Periodic excercising of

stand-by engine generator sets, Ups system testing,Battery system testing , Load optimization in prime power applications , To reduce wet stacking problems , 

Technical specification

ModelInstalled CapacityPower FactorLoad VoltageDimension
W*D*H(mm)
Weight(kg)
AC400-1000KVA-RLR: 800KW
L: 600KVAR
0.83 phase 400V 50HZ/60HZ4058*2438*25916000
AC400-3000KVA-RLR: 2400KW
L: 1800KVAR
6058*2438*289615000
AC400-6000KVA-RLR: 4800KW
L: 3600KVAR
9150*2438*289625000
Main features
Emergency Stop: manually press the Emergency Stop switch on the panel, then load bank is in locked state, and cannot do any operation.
Protection Switch: some protection with switch, when misinformation or in special need, user can close the corresponding protection function temporarily.
Safety Monitor: through indicator lights on main interface, user can monitor system state. When system abnormally stop and protect, software interface prompt the cause immediately.
Overvoltage Protection: the input load voltage is over the safe threshold value, system unload automatically and give an alarm.

Short Circuit Protection and Over Current Protection: when short circuit, fuses in the load bank can insure to unload automatically.

Overheating Protection: temperature is over the safe threshold value, system unload automatically and give an alarm.

Smoke Fog Protection: If there is smoke fog in the container, system cut off load automatically and give an alarm.

Fan Delivery Protection: insufficient air volume with any fan 2450m³/h, system unload automatically and give an alarm.

Fan Delivery Protection: insufficient air volume with any fan 2450m³/h, system unload automatically and give an alarm.
Overload protection with fan: when any fan cannot normally work, the load bank can unload automatically and give an alarm.
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hot Products

AC400V-600KW Dummy Load Bank In Good Performance And Resistive Inductive Introduction AC400V-600KW ...
AC415V-300kW Dummy Load Bank In Good Performance And Resistive Inductive Introduction AC415V-300kW ...
AC400V-500kW Dummy Load Bank With Frequency 50HZ And Best Sales Introduction AC400V-500kW Dummy Load ...
6.6KV-6MW Dummy Load Bank With Frequency 60HZ And Best Performance Sales Introduction AC6.6KV...
400V 1000KVA Dummy Load Bank In Good Performance And Resistive Inductive Introduction AC400V-1000KVA ...
AC480V-600kW Dummy Load Bank In Good Performance And Resistive Inductive Introduction AC480V-600kW ...