SEMKO Certified 40 amp 30ma rccb Type ASi Type A RCCB Circuit Breaker

Country/Region china
City & Province zhejiang
Categories Battery Chargers
InquireNow

Product Details

SEMKO Certified 40 amp 30ma rccb Type ASi Type A RCCB Circuit Breaker

 

Residual Current Circuit Breaker RCCB Type A Type ASi SEMKO Certified

 

VKL11 Residual Current Circuit Breaker RCCB Type A Type AC Type ASi

 

1. General

 

1.1 RCCB Function

 

Control electric circuits.

Protect people against indirect contacts and additional protection against direct contacts.

Protect installations against fire hazard due to insulation faults.

Residual current circuit breakers are used in housing, tertiary sector and industry.

 

1.2 RCCB Selection

Detectable wave form

 

AC class

Tripping is ensured for slowly increasing sinusoidal AC residual currents

 

A class

Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.

 

ASi Type - Full type A features + Si: Super immused (High immunity to unwanted tripping)

Tripping is ensured not only for sinusoidal AC residual currents but also for pulsed DC residual currents whether applied suddenly or increasing slowly. S, G/SI type with filters against spurious tripping caused by harmonics and transient surges. With the impact of 8/20us surge 3000A, this high immunity RCCB will still be in stable status.

Note: Our ASi type includes G/KV function and Si function.

 

 

1.3 RCCB Approvals and certificates

We certify that the RCCB has been tested for the following routine tests as per IS: 12640 (Part 1):2016 and found to be complying

with the requirements.

1. Verification of the operating characteristic as per Seq. - D0 CL9.9

2. Verification of the operation of the test device at the limits of rated voltage as per Seq. - D1 CL9.16

3. High Voltage Test as per D.3 of Annex D

4. Test for standard values of break time and non- actuating time as per CL 5.3.12 (table -1)

 

Tripping sensitivity

10mA - precision instrument leakage protection and bathroom use.

30mA - additional protection against direct contact.

100mA - co-ordinated with the earth system according to the formula I△n < 50/R, to provide protection against indirect contacts;

300mA/500mA - protection against indirect contacts, as well as fire hazard.

Tripping time

Instantaneous

It ensures instantaneous tripping(without time-delay).

Short time delay ASi

(High Immunity/ Avoid nuisance tripping &blinding)

It ensures any tripping at least 10ms.

Selective

It ensures total discrimination with a non selective RCD placed downstream.

 

 

 

RCCB | Residual Current Circuit Breaker

 

2. Technical parameters

 StandardIEC/EN 61008-1 AS/NZS61008.1
Electrical featuresModel No.VKL11
Poles2P, 4P
Rated current In16A, 25A, 32A, 40A, 63A, 80A, 100A
Rated Sensitivity I△n10mA(2P/4P 16A,25A.32A/40A), 30mA, 100mA, 300mA
Rated voltage Ue2P: 240V 4P: 415V
Insulation voltage Ui415V
Rated frequency50/60 Hz
Rated residual making and breaking capacity I△m1500A
Short-circuit current Inc=I△c6000A, 10000A
Type (wave form of the earth leakage sensed)AC, A, ASi, S
break time under I△n≤0.1s(Normal type), 10ms~300ms(ASi type). 150ms~500ms(S type)
Rated impulse withstand voltage(1.2/50) Uimp4kV
Dielectric test voltage at ind. Freq. for 1 min2.5
Pollution degree2
Mechanical featuresElectrical life≥2000
Mechanical life≥2000
Fault current indicatorYes
Terminal protection degreeIP20

Ambient temperature (with

daily average≤35℃)

-25℃ to 50℃
Storage temperate-30℃ to 70℃
InstallationTerminal connection typeCable/Pin-type busbar
Terminal size top/bottom for cable25-35 mm²
18-3/18-2 AWG
Terminal size top/bottom for busbar10/16 mm²
18-8/18-5 AWG
Tightening torque2.5 N·m
22 In-Ibs.
MountingOn DIN rail EN 60715 (35mm) by means of fast clip device
ConnectionFrom top and bottom

 

 

3. RCCB Outline and installation dimensions (mm)

 

Product Description:

Residual Current Circuit Breaker (RCCB) is a device with ISI mark and Inmetro certification. It is specially designed to detect and trip and rated residual current off-time of ≤0.1s. It provides enhanced safety by providing short-circuit protection with rated impulse withstand voltage of 4kV and rated service short-circuit breaking capacity of 10kA, while its rated short-circuit breaking capacity is up to 10kA. This product is essential in avoiding electric shock and fire hazards in both commercial and residential applications.

 

Features:

  • Product Name: Residual Current Circuit Breaker RCCB
  • Certification: Inmetro, ISI, VDE, NF, CE, UKCA
  • Type: Residual Current Circuit Breaker type AC, type A, type ASi
  • Rated Residual Operating Current: 30mA-300mA
  • Rated Current: 16A-100A
  • Rated Service Impulse Withstand Voltage: 6kV
  • Rated Ultimate Short-Circuit Breaking Capacity: 10kA
 

Applications:

HAROK VKL11 Residual Current Circuit Breaker RCCB with Multiple Certification

The HAROK VKL11 Residual Current Circuit Breaker RCCB is a high-performance, reliable and safe circuit breaker. It is certified by many safety organizations, such as NF, SEMKO, VDE, KEMA, ISI, and CE. It has a rated current of 16A-100A, a rated residual current off-time of ≤0.1s, a rated frequency of 50/60Hz.

The Residual Current Circuit Breaker type AC, type A, type ASi is ideal for use in a variety of applications, from residential buildings to commercial buildings. It can be used to monitor, detect, and protect against dangerous electrical conditions, such as overcurrent, short-circuiting, and ground fault current. It is designed to instantly cut off the power supply when the current exceeds the set value, thus providing maximum safety.

The Residual Current Circuit Breaker type VKL11 with CE mark is a reliable and cost-effective solution for ensuring safety in electrical systems. It is designed to detect and protect against dangerous electrical conditions, such as overcurrent, short-circuiting, and ground fault current. It is easy to install and maintain, and has a minimum order quantity of 5000. It is also available at competitive prices with fast delivery time of 4-6 weeks after payment.

HAROK VKL11 Residual Current Circuit Breaker RCCB is high-performance and reliable, and is certified by multiple safety organizations. It is perfect for a variety of applications, and is easy to install and maintain. It has a minimum order quantity of 5000 and is available at competitive prices with fast delivery time of 4-6 weeks after payment.

 

Technical Parameters:

ParameterValue
Rated Operating Duration≤1s
CertificateCE, ISI, NF, SEMKO, VDE, KEMA
Rated Voltage240/415V AC
Rated Short-Circuit Breaking Capacity10kA
Rated Frequency50/60Hz
Rated Impulse Withstand Voltage4kV
Rated Service Impulse Withstand Voltage6kV
Rated Operating Frequency50/60Hz
Rated Residual Operating Current30mA-300mA
Rated Ultimate Short-Circuit Breaking Capacity10kA
 

Customization:

Residual Current Circuit Breaker RCCB

Brand Name: HAROK
Model Number: VKL11
Place of Origin: CHINA
Certification: NF, SEMKO, VDE, KEMA, ISI, CE
Minimum Order Quantity: 5000
Packaging Details: PAPER CARTON
Delivery Time: 4-6 weeks after payment
Payment Terms: FOB NINGBO or SHANGHAI
Supply Ability: 100,000 PCS PER MONTH
Rated Frequency: 50/60Hz
Rated Ultimate Short-Circuit Breaking Capacity: 10kA
Rated Current: 16A-100A
Certificate: CE, ISI, NF, SEMKO, VDE, KEMA

The HAROK VKL11 Residual Current Circuit Breaker RCCB is certified by Inmetro, NF, SEMKO, VDE, KEMA, ISI and CE. It has a Minimum Order Quantity of 5000 and Packaging Details of PAPER CARTON. The Delivery Time is 4-6 weeks after payment and the Payment Terms is FOB NINGBO or SHANGHAI. The Supply Ability is 100,000 PCS PER MONTH with Rated Operating Frequency of ≤0.2times/h. It has a Rated Frequency of 50/60Hz, Rated Ultimate Short-Circuit Breaking Capacity of 10kA and a Rated Residual Operating Current of 30mA, 100mA, 300mA.

 

Packing and Shipping:

Packaging and Shipping

Residual Current Circuit Breaker (RCCB) is securely packaged and shipped using appropriate methods to ensure that the product arrives in its intended condition to the customer.

The product is packaged with bubble wrap and placed in a cardboard box. If it is being shipped over long distances, the cardboard box is further placed in a wooden crate to ensure safe delivery of the product.

The product is shipped using appropriate methods, such as air freight, sea freight, or road transport, depending on the destination of the product. The product is adequately insured to cover any loss or damage during transit.

Hot Products

VML01 Residual Current Circuit Breaker type A, type AC, type ASi 30mA-300mA NF SEMKO VDE KEMA ...
HAROK 50/60 Hz 40a 100ma RCCB Inmetro 240V 415V rccb in electrical VML01 Residual Current Circuit ...
VKL11 RCCB Residual Current Circuit Breaker break time under I△n 10ms~300ms type G short-time delay ...
SEMKO Certified 40 amp 30ma rccb Type ASi Type A RCCB Circuit Breaker Residual Current Circuit ...
rccb 2 pole 40 amp Residual Current Circuit Breaker Portable RCCB UL1053 *, *::before, *::after {box...
Residual Current Circuit Breaker NF SEMKO VDE KEMA Certified, 6kV Rated Service Impulse Withstand ...