Home Companies Yueqing Vorax Electric CO.,LTD

240/415VAC Residual Current Circuit Breakers RCCB Type AC NF SEMKO VDE KEMA Inmetro

Yueqing Vorax Electric CO.,LTD

Contact Us

[China] country

Trade Verify

Address: Liuhuang Road, Liushi Town, Yueqing City, Zhejiang Province

Contact name:Wellkins Lew

Inquir Now

Yueqing Vorax Electric CO.,LTD

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

240/415VAC Residual Current Circuit Breakers RCCB Type AC NF SEMKO VDE KEMA Inmetro

Country/Region china
City & Province zhejiang
Categories Battery Chargers
InquireNow

Product Details

VML01 Residual Current Circuit Breaker type A, type AC, type ASi 30mA-300mA NF SEMKO VDE KEMA Inmetro

 

VML01 Residual Current Circuit Breaker RCCB Type A Type AC Type ASi Inmetro​

 

1. General

 

1.1 Function

 

Control electric circuits.

Protect people against indirect contacts and additional protection against direct contacts.

Protect installations against fire hazard due to insulation faults.

Residual current circuit breakers are used in housing, tertiary sector and industry.

 

1.2 Selection

Detectable wave form

 

AC class

Tripping is ensured for slowly increasing sinusoidal AC residual currents

 

A class

Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.

 

ASi Type - Full type A features + Si: Super immused (High immunity to unwanted tripping)

Tripping is ensured not only for sinusoidal AC residual currents but also for pulsed DC residual currents whether applied suddenly or increasing slowly. S, G/SI type with filters against spurious tripping caused by harmonics and transient surges. With the impact of 8/20us surge 3000A, this high immunity RCCB will still be in stable status.

Note: Our ASi type includes G/KV function and Si function.

 

 

1.3 Approvals and certificates

We certify that the RCCB has been tested for the following routine tests as per IS: 12640 (Part 1):2016 and found to be complying

with the requirements.

1. Verification of the operating characteristic as per Seq. - D0 CL9.9

2. Verification of the operation of the test device at the limits of rated voltage as per Seq. - D1 CL9.16

3. High Voltage Test as per D.3 of Annex D

4. Test for standard values of break time and non- actuating time as per CL 5.3.12 (table -1)

 

Tripping sensitivity

10mA - precision instrument leakage protection and bathroom use.

30mA - additional protection against direct contact.

100mA - co-ordinated with the earth system according to the formula I△n < 50/R, to provide protection against indirect contacts;

300mA/500mA - protection against indirect contacts, as well as fire hazard.

Tripping time

Instantaneous

It ensures instantaneous tripping(without time-delay).

Short time delay ASi

(High Immunity/ Avoid nuisance tripping &blinding)

It ensures any tripping at least 10ms.

Selective

It ensures total discrimination with a non selective RCD placed downstream.

 

 

 

RCCB | Residual Current Circuit Breaker

 

2. Technical parameters

 StandardIEC/EN 61008-1 AS/NZS61008.1
Electrical featuresModel No.VML01
Poles2P, 4P
Rated current In16A, 25A, 32A, 40A, 63A, 80A, 100A
Rated Sensitivity I△n10mA(2P/4P 16A,25A.32A/40A), 30mA, 100mA, 300mA
Rated voltage Ue2P: 240V 4P: 415V
Insulation voltage Ui415V
Rated frequency50/60 Hz
Rated residual making and breaking capacity I△m1500A
Short-circuit current Inc=I△c6000A, 10000A
Type (wave form of the earth leakage sensed)AC, A, ASi, S
break time under I△n≤0.1s(Normal type), 10ms~300ms(ASi type). 150ms~500ms(S type)
Rated impulse withstand voltage(1.2/50) Uimp4kV
Dielectric test voltage at ind. Freq. for 1 min2.5
Pollution degree2
Mechanical featuresElectrical life≥2000
Mechanical life≥2000
Fault current indicatorYes
Terminal protection degreeIP20

Ambient temperature (with

daily average≤35℃)

-25℃ to 50℃
Storage temperate-30℃ to 70℃
InstallationTerminal connection typeCable/Pin-type busbar
Terminal size top/bottom for cable25-35 mm²
18-3/18-2 AWG
Terminal size top/bottom for busbar10/16 mm²
18-8/18-5 AWG
Tightening torque2.5 N·m
22 In-Ibs.
MountingOn DIN rail EN 60715 (35mm) by means of fast clip device
ConnectionFrom top and bottom

 

 

3. RCCB Outline and installation dimensions (mm)

 

Product Description:

Residual Current Circuit Breaker RCCB

Residual Current Circuit Breaker RCCB is a device designed to protect people and electrical equipment from the potential risks of electric shock. It features a rated voltage of 240/415V AC, and is certified by CE, ISI, NF, SEMKO, VDE, KEMA, Inmetro. In addition, it has a rated operating frequency of 50/60Hz, a rated current of 30mA-300mA, and a rated operating duration of ≤1s.

This Residual Current Circuit Breaker RCCB provides superior protection against electrical shock and is compliant with Inmetro, NF, SEMKO, VDE, Inmetro and KEMA standards. It is designed to detect and trip on residual currents as low as 30mA-100mA, and will trip within 1 second of current detection. This makes it the ideal choice for residential, commercial and industrial applications.

With its high performance and reliable design, the Residual Current Circuit Breaker RCCB is the perfect solution for ensuring safety and protection in any power system.

 

Features:

  • Product Name: Residual Current Circuit Breaker RCCB
  • Rated Voltage: 240/415V AC
  • Rated Impulse Withstand Voltage: 4kV
  • Certificate: CE, ISI, NF, SEMKO, VDE, KEMA, Inmetro
  • Rated Ultimate Short-Circuit Breaking Capacity: 10kA
  • Residual Current Circuit Breaker NF SEMKO VDE KEMA: Yes, Residual Current Circuit Breaker RCCB is NF SEMKO VDE KEMA Inmetro certified.
  • Residual Current Circuit Breaker with ISI mark: Yes, Residual Current Circuit Breaker RCCB is ISI marked.
 

Applications:

HAROK VML01 Residual Current Circuit Breaker (RCCB) with ISI Mark

HAROK VML01 Residual Current Circuit Breaker (RCCB) is a reliable, safe and cost-effective device for preventing electric shock due to earth leakage current. It can be used for AC circuit with rated voltage of 240/415V and rated current of 30mA-300mA. It is designed to meet NF, SEMKO, VDE, KEMA, Inmetro, ISI and CE certifications, providing customers with the highest level of safety and reliability. The rated impulse withstand voltage of this RCCB is 4kV and the rated service impulse withstand voltage is 6kV, and the rated operating frequency is 50/60Hz.

This RCCB is widely used in residential and commercial buildings, as well as in industrial facilities, to protect the safety of personnel and equipment from electric shocks caused by earth leakage current. It can be used in a variety of applications, such as air-conditioning, lighting, power distribution, and electric welding. It is an ideal device for protecting personnel and equipment in harsh working environments.

HAROK VML01 Residual Current Circuit Breaker (RCCB) meets the highest safety and quality standards and is available in a minimum order quantity of 5000. The delivery time is 4-6 weeks after payment, and the payment terms are FOB NINGBO or SHANGHAI. This RCCB is supplied with a paper carton for easy storage and transport. With a capacity of 100,000 PCS per month, HAROK VML01Residual Current Circuit Breaker (RCCB) is the perfect solution for your safety needs.

 

Technical Parameters:

ParametersValue
Rated Voltage240/415V AC
Rated Ultimate Short-Circuit Breaking Capacity10kA
Rated Frequency50/60Hz
Rated Operating Duration≤1s
Rated Current30mA-300mA
CertificateCE, ISI, NF, SEMKO, VDE, KEMA, Inmetro
Rated Insulation Voltage500V
Rated Impulse Withstand Voltage4kV
 

Customization:

Residual Current Circuit Breaker RCCB
Product Details
  • Brand Name: HAROK
  • Model Number: VML01
  • Place of Origin: CHINA
  • Certification: NF, SEMKO, VDE, KEMA, ISI, CE, Inmetro
  • Minimum Order Quantity: 5000
  • Packaging Details: PAPER CARTON
  • Delivery Time: 4-6 weeks after payment
  • Payment Terms: FOB NINGBO or SHANGHAI
  • Supply Ability: 100,000 PCS PER MONTH
  • Rated Voltage: 240/415V AC
  • Residual Current Circuit Breaker type EV: Residual Current Circuit Breaker Inmetro
  • Rated Short-Circuit Breaking Capacity: 10kA
  • Rated Service Short-Circuit Breaking Capacity: 10kA
  • Rated Ultimate Short-Circuit Breaking Capacity: 10kA
  • Rated Residual Operating Current: 30mA-300mA
 

Packing and Shipping:

Packaging and Shipping of Residual Current Circuit Breaker RCCB

The Residual Current Circuit Breaker RCCB is packaged in a standard cardboard box with a styrofoam insert. The product is shipped in a sturdy cardboard box, with appropriate padding and seals to protect it during transit. All products are shipped via insured and traceable courier services.

Hot Products

CE/RoHS/FCC Certified Plastic PRCD Plug, 10A Current, UL/VDE/CCC Approved PRCD plug General 16 A ...
PRCD Adaptor safety device for households, workplaces, and construction for electrical appliances ...
VFL001 Rated 6kA Service Short-Circuit Breaking Capacity Residual Current Circuit Breaker (RCCB) ...
VML01 Residual Current Circuit Breaker type A, type AC, type ASi 30mA-300mA NF SEMKO VDE KEMA ...
HAROK 50/60 Hz 40a 100ma RCCB Inmetro 240V 415V rccb in electrical VML01 Residual Current Circuit ...
VKL11 RCCB Residual Current Circuit Breaker break time under I△n 10ms~300ms type G short-time delay ...