Home Companies Xi 'an West Control Internet Of Things Technology Co., Ltd.

22.5mA Guided Wave Radar Level Transmitter Pressure Type 1.8GHz Water Level Sensor Radar

Xi 'an West Control Internet Of Things Technology Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: Block V5, Ronghao Industrial Town, Gaoling District, Xi'an City, Shaanxi Province

Contact name:Gao

Inquir Now

Xi 'an West Control Internet Of Things Technology Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

22.5mA Guided Wave Radar Level Transmitter Pressure Type 1.8GHz Water Level Sensor Radar

Country/Region china
City & Province Shaanxi
InquireNow

Product Details

 

NYRD705 ( Stainless Steel )1.8GHz Guided Wave Radar Level Meter 

 

NYRD705 Stainless Steel High temperature and pressure type 1.8GHz Guided Wave Radar Level Meter Level Transmitter

The guided wave radar level meter is a level meter based on the principle of time domain reflection (TDR). The electromagnetic pulse of the radar level gauge propagates along the steel cable or probe at the speed of light. Part of the pulse of the level meter is reflected to form an echo and return to the pulse transmitter along the same path. The distance between the transmitter and the surface of the measured medium is proportional to the propagation time of the pulse during that period, and the liquid level height is calculated.

 

Radar Level Meter Technical Parameter

 

Parameters

Frequency: 100MHZ-1.8GHZ

Measuring range:-cable :0-30m; rod, coaxial :0-6m

Repeatability: ± 3mm

Resolution: 1mm

Sampling: echo 55 samples / s

Response speed: 0.2S (depending on the actual usage)

Output current signal :4-20mA

Accuracy: <0.1%

Communication InterfaceHART communication protocol
Process connection

G1-1/2

Flange DN50, DN80, DN100, DN150

Process pressure-1 ~ 40bar
Power

Power: 24VDC (± 10%), ripple voltage: 1Vpp

Power consumption: max 22.5mA

Environmental conditionstemperature -40 ℃ ~ +80 ℃
Housing protection gradeIP68
Explosion levelsEXiaIICT6
Instrumentation power supply and signal output wire connection

Sharing a two-core shielded cable

Cable entry: 2 M20 × 1.5 (the cables diameter of 5 - 9mm)

 

 Note: Products can be customized according to the specific requirements of users!

 

Measurement Range

 

 

Symbol explanation:

    H---- Measurement range

    L---- Empty tank distance

    B---- The blind area at the top

    E---- The minimum distance between the probe and the tank wall

The blind area refers to the minimum distance between the highest level of the material surface and the measurement reference point.

The bottom blind area refers to the distance near the cable bottom that cannot be precisely measured.

The effective distance is the one between the top blind area and the bottom blind area.

 

Note:Only when the material level is at between the top and bottom blind areas can a reliable measurement of the material level be guaranteed.

 

Installation Guide

 

The following installation guide is suitable for that of cable and rod probes for measurement of solid particles and liquid. The coaxial tubular probe is applied only to the liquid object.

 

Installation position:

Try to stay away from the outlet and inlet.

The meter should not touch the tank internal wall for metal tanks and plastic tanks. If it is a metal tank, the material level meter should not be installed at the center of the tank.

It is proposed to install at 1/4 of the silo diameter.

Probes of cable or rod types should keep a distance away from the tank wall not less than 30cm.

The probe bottom should be about 30mm to the tank bottom.

The probe should keep a distance not less than 200mm from the obstacles within the tank.

The sensor can be installed at the center of the tank top, if the bottom of the container is a cone, so the measurement can be taken to the tank bottom.

 

The picture on the right shows the rod-type radar installation diagram, mainly used for liquid level measurement.

 

Radar Level Meter Electricalconnections

 

◎ Supply voltage


(4 ~20)mA/HART(Two-wire)
The power supply and the output current signal share a two-core shielded cable. Refer to the technical data for the specific supply voltage range. For the intrinsically safe type, a safety barrier must be added between the power supply and the instrument.

 

(4~20)mA/HART(Four-wire)
The power supply and the current signal are separated, and each uses a two-core shielded wire. Refer to the technical data for the specific supply voltage range.

 

RS485/Modbus
The power supply and the Modbus signal are separated, and each uses a two-core shielded wire. For specific supply voltage range see technical data .

 

Hot Products

NYRD702 ( Stainless Steel )1.8GHz Guided Wave Radar Level Meter The guided wave radar level meter is ...
NYRD703 ( Stainless Steel )1.8GHz Guided Wave Radar Level Meter The guided wave radar level meter is ...
NYRD705 ( Stainless Steel )1.8GHz Guided Wave Radar Level Meter NYRD705 Stainless Steel High ...
NYRD801 Intelligent Radar Level Meter Radar Level Meter Operating Principle Radar level meter is ...
NYRD801 Intelligent Radar Level Meter Radar Level Meter Operating Principle Low emission energy ...
NYRD801 Intelligent Radar Level Meter Radar Level Meter Operating Principle Low emission energy ...